Technical Data
* The data are only valid for the values displayed at the test instrument.
Data which are transmitted via the USB interface may deviate.
RCD test
Time to trip 0 ... 400 ms 5 ms
Test
current:
30 mA
At nominal voltage of 230 / 240 V and 50 / 60 Hz,
only during battery operation with mains
connected
PRCD:
Time to trip 0 ... 400 ms 2 ms
Test
current:
30 mA
At nominal voltage of 230 / 240 V and 50 / 60 Hz,
Function test (not during battery operation)
Line voltage (RMS)
U LN
90 ... 264 V AC
(45 ... 440 Hz)
0.1 V
5.0% rdg.
(2.5% rdg. + 1 d)
264 V
AC
Cont.
Load Current
(RMS) I L
0.02 ... 16.00 A AC
(45 ... 440 Hz)
10 mA
Shutdown by mains relay at: I
V
> 16 A~ where t > 0.5 s
Shutdown by mains relay at: I
V
> 4 A~ where internal
temperature > 70 C
5.0% rdg.
(2.5% rdg. + 1 d)
4 A Cont.
Active power P 10 ... 4000 W 1 W
Measured value P and calculated value S are compared, and
the smaller of the two is displayed.
Shutdown at internal temperature > 70 C
f < 100 Hz
7.5% rdg.
P > 10 W, PF > 0.5
f < 100 Hz
(5% rdg. + 10 d)
< 1000
W
< 4000
W
Cont.
Int.
f 100 Hz
10% rdg.
P > 10 W, PF > 0.5
f 100 Hz
(7.5% rdg. + 10 d)
Apparent power S 10 ... 4000 W 1 VA
Calculated vale U
L–N
• I
V
[OL display for ULN or I L overload]
Shutdown at internal temperature > 70 C
f < 100 Hz
7.5% rdg.
P > 10 W
f < 100 Hz
(5% rdg. + 10 d)
< 1000
W
< 4000
W
Cont.
Int.
f 100 Hz
10% rdg.
P > 10 W
f 100 Hz
(7.5% rdg. + 10 d)
Power factor PF
with sinusoidal
waveshape: cos
0.00 ... 1.00
inductive
0.01 Calculated value P / S, display as of P > 10 W
f < 100 Hz
7.5% rdg.
P > 10 W, PF > 0.5
f < 100 Hz
(5% rdg. + 10 d)
——
f 100 Hz
10% rdg.
P > 10 W, PF > 0.5
f 100 Hz
(7.5% rdg. + 10 d)
On-time t
(E = P · t)
00:00:00 ... >
99:00:00 s
1 s On-time, line voltage to test socket, for calculating energy
——
Func-
tion
Measured
Quantity
Measuring Range /
Nominal Range of
Use
Reso-
lution
Addi-
tional
Informa-
tion
Open-
Circuit
Voltage
U
0
Addi-
tional
Infor-
mation
Short-
circuit
current
I
K
Int.
Resis-
tance
R
I
Ref.
Resis-
tance
R
REF
Measuring
Uncertainty *
Intrinsic
Uncertainty *
Overload
Capacity
Value Time
127


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUSTAR FM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUSTAR FM in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info