34 GMC-I Messtechnik GmbH
Initial Start-Up – Setup
Automatic Update Sequence
1 Update preparation: advancing blue bar
2 Operating system is rebooted: initial screen with an advancing blue bar –
pause for approx. 30 seconds
3 The update is loaded (approx. 7 min.): two advancing blue bars
4 Operating system is rebooted: initial screen with an advancing blue bar
5 Calibration prompt
6 Login window appears
7 The software update has been completed and the CF card can be removed
after pressing the button at the left-hand side of the slot.
Beachten Sie Folgendes bei einem Update von Version 1.8.2 auf
Version 1.8.3 oder höher (nur SECUSTAR FM):
As of version 1.8.2, the test system has several hierarchies. For this
reason, you’ll need an LHTIF.exe file (version >= 1.05.0013) or
PS3 as of version 9.10.0113 in order to exchange data with PS3.
All of the necessary files can be downloaded from our website at
http://www.gossenmetrawatt.com/deutsch/produkte/secustar-up.htm
.
It’s important to sort data into the correct hierarchies when
updating.
If you’re working with PS3 (lower than version 9.10.0.113) or
LHTIF.exe (version >= 1.05.0013) and test system firmware version
1.8.2, and if data are included in the test system in the HK11
hierarchy, they must be transferred to hierarchy HK4.
Proceed as follows to this end:
Ð Back your data up to an XML file.
Ð Open the XML file in an editor.
Ð Replace all occurrences of hierarchy-ref=“11“ in the text with
hierarchy-ref=“4“.
Ð Save the XML file.
Ð Run DB Init at the test system.
Ð Import the modified XML file.
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUSTAR FM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUSTAR FM in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info