590782
19
Zoom out
Zoom in
Previous page
1/86
Next page
O
S
D
O
perating M
a
S
EC
U
D
EFIBRI
L
a
nual
U
LIF
E
L
LATOR
A
E
DF
B
A
NALYZ
E
B
ASE
E
R
3-349-8
1
0
4-03
/6.14
2 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
Contents
WARNINGS, CAUTIONS, NOTICES ....................................................................................................... 3
DESCRIPTION ........................................................................................................................................ 9
OVERVIEW ............................................................................................................................................. 16
DEFIBRILLATOR ANALYZER ................................................................................................................. 23
MAIN SCREEN .......................................................................................................................... 23
ECG WAVEFORMS SCREEN ................................................................................................... 30
PLAYBACK LAST PULSE SCREEN ......................................................................................... 34
START CHARGE TIMER SCREEN ........................................................................................... 38
PRINT HEADER ........................................................................................................................ 38
SELF TEST WAVEFORM .......................................................................................................... 40
RUNNING A DEFIBRILLATION TEST ...................................................................................... 42
INTRODUCTION.......................................................................................................... 42
DEFIBRILLATION TEST .............................................................................................. 44
CARDIOVERSION TEST ............................................................................................. 48
CHARGE TIME TEST .................................................................................................. 52
SHOCK ADVISORY ALGORITHM TEST .................................................................... 54
MESSAGES ............................................................................................................................................. 56
SYSTEM SETUP ..................................................................................................................................... 57
POWER UP SETTINGS .......................................................................................................................... 59
AUTO SEQUENCE FUNCTION .............................................................................................................. 61
VIEW MODE .............................................................................................................................. 63
RUN MODE ............................................................................................................................... 66
PROGRAMMING AUTOSEQUENCES ................................................................................................... 71
WARRANTY ............................................................................................................................................ 81
SPECIFICATIONS ................................................................................................................................... 82
GMC-I Messtechnik GmbH 3
SECULIFE DF
BASE
WARNING - USERS
The SECULIFE DF
BASE
analyzer is for use by
skilled technical personnel only.
WARNING - USE
The SECULIFE DF
BASE
Analyzer is intended
for testing only and it should never be used
in diagnostics, treatment or any other
capacity where it would come in contact
with a patient.
WARNING - MODIFICATIONS
The SECULIFE DF
BASE
Analyzer is intended for
use within the published specifications. Any
application beyond these specifications or
any unauthorized user modifications may
result in hazards or improper operation.
WARNING - CONNECTIONS
All connections to patients must be removed
before connecting the Device Under Test
(DUT) to the Analyzer. A serious hazard may
occur if the patient is connected when
testing with the Analyzer.
Do not connect any leads from the
patient directly to the Analyzer or
DUT.
WARNING - POWER ADAPTER
Unplug the Power Adapter before
cleaning the surface of the
Analyzer.
4 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
WARNING - LIQUIDS
Do not submerge or spill liquids on the
Analyzer. Do not operate the Analyzer if
internal components not intended for use
with fluids may have been exposed to fluid,
as the internal leakage may have caused
corrosion and be a potential hazard.
CAUTION - SERVICE
The SECULIFE DF
BASE
Analyzer is intended to be
serviced only by authorized service personnel.
Troubleshooting and service procedures should
only be performed by qualified technical
personnel.
CAUTION - ENVIRONMENT
The SECULIFE DF
BASE
Analyzer is
intended to function between 15 and 40
°C.
Exposure to temperatures outside this
range can adversely affect the performance
of the Analyzer.
CAUTION - CLEANING
Do not immerse. The Analyzer should be cleaned
by wiping gently with a damp, lint-free cloth.
A mild detergent can be used if desired.
CAUTION - INSPECTION
The SECULIFE DF
BASE
Analyzer should
be inspected before each use for wear
and the Analyzer should be serviced
if any parts are in question.
GMC-I M
e
e
sstechnik
G
G
mbH
NOTI
The
S
d
transc
wit
h
throu
g
CE – I
N
S
ECULI
F
d
etermi
n
utaneou
h
in their
p
g
h the m
e
N
DIC
A
F
E DF
BASE
n
e that d
e
s pace
m
p
erform
a
e
asure
m
A
TION
S
A
nalyz
e
e
fibrillat
o
m
akers a
r
a
nce sp
e
m
ent of e
n
S
FOR
U
e
r is use
d
o
rs and
r
e perfo
r
e
cificati
o
n
ergy o
u
U
SE
d
to
r
ming
o
ns
u
tput.
SECULIFE
5
DF
BASE
6 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
NOTICE – ABBREVIATIONS
A, Amps Amperes
BPM
Beats Per Minute
c
centi- (10
-2
)
C Celsius
° degree
dt Delta Time, Change in Time
DUT Device Under Test
E Energy
ECG Electrocardiogram
Euro European
Hz hertz
3
)
kg kilograms
lbs pounds
µ micro- (10
-6
)
µA
microampere
µH microhertz
µV microvolt
µsec
microsecond
m
milli- (10
-3
)-
mA milliampere
mm millimeter
ms, mS,
millisecond
msec
mV millivolts
ohm
P Power
ppm pulse per minute
R Resistance, ohms
Sec, S seconds
US United States
V volt
VDC Direct Current Voltage
GMC-I Messtechnik GmbH 7
SECULIFE DF
BASE
8 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
NOTICE – DISCLAIMER
USER ASSUMES FULL RESPONSIBILITY FOR UNAUTHORIZED
EQUIPMENT MODIFICATIONS OR APPLICATION OF
EQUIPMENT OUTSIDE OF THE PUBLISHED INTENDED USE
AND SPECIFICATIONS. SUCH MODIFICATIONS OR
APPLICATIONS MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
NOTICE – DISCLAIMER
GMC-I MESSTECHNIK GMBH RESERVES THE RIGHT TO
MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT
ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE
DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST
POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL
HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE
ACCURATE. HOWEVER, NO RESPONSIBILITY
IS ASSUMED FOR INACCURACIES.
NOTICE – CONTACT INFORMATION
GMC-I Messtechnik GmbH
Südwestpark 15
90449 Nürnberg
Germany
Phone: +49 911 8602-111
Fax:
+49 911 8602-777
www.gossenmetrawatt.com
e-mail: info@gossenmetrawatt.com
GMC-I Messtechnik GmbH 9
SECULIFE DF
BASE
SECULIFE DF
BASE
is a microprocessor-based instrument that is used in the testing of defibrillators. It
measures the energy output and provides information about the defibrillation pulse. It is used on
manual, semi-automatic and automatic defibrillators with monophasic or biphasic outputs.
SECULIFE DF
BASE
additionally provides a Transcutaneous Pacemaker analysis function. It measures
and displays pacer pulse information as well as performing Refractory Period, Sensitivity and Immunity
testing.
It has a built in 50 ohm human body simulation load as well as 12 lead ECG with arrhythmias and
performance waveforms. Additionally, it has a Centronics printer port, a serial port, oscilloscope output,
high-level ECG output, as well as provision for a battery eliminator.
SECULIFE DF
BASE
makes viewing and selecting the desired waveforms and test data quick and
intuitive, with all operational information being available on the 240 by 64 pixel graphic display, allowing
for easy maneuvering through parameters and scrolling through available options.
NOTE
This instrument is intended for use by
Trained Service Technicians.
DEFIBRILLATOR ANALYZER
10 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
The following are highlights of some of the main features:
GENERAL
SIMPLE TO OPERATE
GRAPHICS DISPLAY WITH SIMULTANEOUS DETAILED STATUS OF PARAMETERS
AND SCROLLING CONTROL OF OPTIONS
ON SCREEN VIEWING OF DEFIBRILLATOR AND PACEMAKER WAVEFORMS
DROP DOWN CHOICE SCREENS LIST ALL OPTIONS FOR PARAMETERS
MONOPHASIC AND BIPHASIC COMPATIBLE
5000 V, 1000 JOULE CAPACITY
HIGH AND LOW RANGES
CARDIOVERSION DELAY MEASUREMENT
CHARGE TIME MEASUREMENT
WAVEFORM STORAGE AND PLAYBACK
10 UNIVERSAL PATIENT LEAD CONNECTORS
25 PIN CONNECTOR FOR CENTRONICS PRINTER
9 VOLT BATTERY POWER
LOW BATTERY INDICATOR
AVAILABLE BATTERY ELIMINATOR
DISPLAY BACKLIGHT
FULL REMOTE OPERATION VIA RS-232
FLASH PROGRAMMABLE FOR UPGRADES
AUTO SEQUENCE TESTING CAPABLE OF STORING 50 CUSTOM TEST SEQUENCES
GMC-I Messtechnik GmbH 11
SECULIFE DF
BASE
ENERGY OUTPUT MEASUREMENT GENERAL
The unit measures the energy in the output pulse of both monophasic and biphasic defibrillators.
PULSE TYPE: Monophasic or Biphasic
LOAD RESISTANCE: 50 ohm +/- 1%, non-inductive (<1 µH)
DISPLAY RESOLUTION: 0.1 Joules
MEASUREMENT TIME WINDOW: 100 ms
ABSOLUTE MAX PEAK VOLTAGE: 6000 Volts
CARDIOVERSION DELAY: 0 to 6000 ms
CARDIOVERSION RESOLUTION: 0.1 ms
ENERGY OUTPUT MEASUREMENT HIGH RANGE
The high range allows for a large pulse with high voltage and current.
VOLTAGE: <5000 Volts
MAX CURRENT: 100 Amps
MAX ENERGY: 1000 Joules
TRIGGER LEVEL: 100 Volts
PLAYBACK AMPLITUDE: 1 mV / 1000 V Lead I
TEST PULSE: 125 Joules +/- 20%
ENERGY OUTPUT MEASUREMENT LOW RANGE
The low range allows greater resolution on smaller pulses.
VOLTAGE: <1000 Volts
MAX CURRENT: 20 Amps
MAX ENERGY: 50 Joules
TRIGGER LEVEL: 20 Volts
PLAYBACK AMPLITUDE: 1 mV / 1000 V Lead I
TEST PULSE: 5 Joules +/- 20%
12 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
ENERGY OUTPUT MEASUREMENT OTHER
OSCILLOSCOPE OUTPUT
HIGH MEASUREMENT RANGE: 1000:1 amplitude-attenuated
LOW MEASUREMENT RANGE: 200:1 amplitude-attenuated
WAVEFORM PLAYBACK
OUTPUT – LEAD 1 & PLATES
GRAPHICS SCREEN
200:1 Time Base Expansion
SYNC TIME MEASUREMENTS
TIMING WINDOW: Starts at peak of each R-wave
TEST WAVEFORMS: All waveform simulations available
CHARGE TIME MEASUREMENT
From 0 .1 to 99.9 sec
ECG FUNCTIONS
The unit can produce a wide variety of ECG simulations. The user simply selects the parameters that
match the desired output.
RATE: 30,40,45,60,80,90,100,120,140,160,180,200,220,240,260,280,300 BPM
AMPLITUDE: 0.50,1.0,1.5,2.0 mV (Lead II)
ECG-PERFORMANCE FUNCTIONS
The unit can generate Sine, Square, Triangular, and Pulse waveforms with adjustable amplitudes for
performance testing.
SINE: 0.1,0.2,0.5,5,10,40,50,60,100 Hz
SQUARE: 0.125,2 Hz
TRIANGLE: 2,2.5 Hz
PULSE: 30,60,120 BPM; 60 ms WIDTH
AMPLITUDE: 0.5,1.0,1.5,2.0 mV (Lead II)
GMC-I Messtechnik GmbH 13
SECULIFE DF
BASE
ARRHYTHMIA FUNCTIONS
The unit can simulate 12 different arrhythmias.
VENTRICULAR FIBRILLATION
ATRIAL FIBRILLATION
SECOND DEGREE A-V BLOCK
RIGHT BUNDLE BRANCH BLOCK
PREMATURE ATRIAL CONTRACTION
EARLY PVC
STANDARD PVC
R ON T PVC
MULTIFOCAL PVC
BIGEMINY
RUN OF 5 PVC
VENTRICULAR TACHYCARDIA
SHOCK ADVISORY TESTS
The unit can simulate 8 different waveforms to test the shock algorithm of advanced defibrillators:
ASYSTOLE
COARSE VENTRICULAR FIBRILLATION
FINE VENTRICULAR FIBRILLATION
MULTIFOCAL VENTRICULAR TACHYCARDIA @ 140 BPM
MULTIFOCAL VENTRICULAR TACHYCARDIA @ 160 BPM
POLYFOCAL VENTRICULAR TACHYCARDIA @ 140 BPM
POLYFOCAL VENTRICULAR TACHYCARDIA @ 160 BPM
SUPRAVENTRICULAR TACHYCARDIA @ 90 BPM
14 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
ACCESSORIES
BC20 - 40032 INTERNAL PADDLE ADAPTERS (2 adapters)
BC20 - 21103 BATTERY ELIMINATOR (120 VAC) (US Version)
BC20 - 21101 BATTERY ELIMINATOR (220 VAC) (Euro Version)
BC20 - 00427 PLASTIC ELECTRODE PLATES (2 plates)
OPTIONAL ACCESSORIES
BC20 - 30108 MEDIUM SOFT SIDED CARRYING CASE BC20 -
41341 COMMUNICATION CABLE (DB 9 M to DB 9 F)
BC20 - 00420 PHYSIO-CONTROL DEFIB / PACE TEST CABLE
BC20 - 00421 MARQUETTE DEFIB / PACE TEST CABLE BC20 -
00423 ZOLL DEFIB/PACE TEST CABLE
BC20 - 00426 HP / AGILENT / LAERDAL / AAMIDEFIB / PACE TEST CABLE
GMC-I Messtechnik GmbH 15
SECULIFE DF
BASE
This page intentionally left blank.
16
SECULIF
This sec
t
present.
10 Univ
e
Patient
L
Connect
o
RA R
LA
L
RL(-) N
LL
F
V1
C1
V2
C2
V3
C3
V4
C4
V5
C5
V6
C6
Back Lig
for turni
n
and off t
h
backligh
t
L
F
l
t
E DF
BASE
t
ion looks a
e
rsal
L
ead
o
rs:
ht Key
n
g on
h
e
t
L
arge Defib
F
ixed 50 oh
m
l
oad for Defi
b
t
esting
t the layou
t
Plates:
m
input
b
rillator
t
of SECUL
I
LCD
G
Show
s
Data
a
9
V
C
o
O
I
FE DF
BASE
a
G
raphical Di
s
s
Parameter
s
a
nd Wavefor
V
Battery
o
mpartment
(Rear)
OVER
V
a
nd gives d
s
play:
s
for Test
m
s
V
IEW
e
scriptions
GMC
-
of the ele
m
5
K
f
u
T
h
l
a
b
o
t
h
c
h
b
a
o
p
-
I Messtech
n
m
ents that a
Light Touch
eys for Dyn
a
u
nctions:
h
ese keys ar
e
a
belled in the
o
ttom portion
h
e screen an
d
h
ange functi
o
a
sed on
p
erating mod
Range Key
for selectin
g
Defib input
range high
o
low and pa
c
mode
n
ik GmbH
re
a
mic
e
of
d
o
n
e.
g
o
r
c
e
GMC-I Messtechnik GmbH 17
SECULIFE DF
BASE
This section looks at the layout of the back and gives descriptions of the elements that are present.
Oscilloscope
output
BNC connector
for easy
viewing of input
waveforms
Power Switch
Parallel Port
Female 25-Pin
A
C Ada
p
tor/
Hi
g
h Level
Serial Por
t
D-Sub
Battery
ECG output
Female 9-
Conector
Eliminator
RCA Jack
Pin D-Sub
2.1 mm Micro
Connector
Jack
18 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
General Operation
The unit is controlled by 7 light touch keys. They allow the user to move around within the displayed
parameters, select the desired options, choose a specific category and control the setup for the unit.
When a key is depressed there is an audio click when it is accepted, or a razz tone if the key is invalid.
A large LCD graphics display with backlight provides the user with information about the current status of
the device configuration options, test results and more. The display identifies the function of each key on a
dynamic basis. As the operation mode changes, the key functions change to suit the operating mode.
Range Key
The key scrolls through the ranges of the SECULIFE DF
BASE
analyzer. Depressing the key will
allow the user to select between High Defibrillator Range (1000J max), Low Defibrillator Range (50J
max) and Pacemaker Range. The default mode on power up is High Defibrillator Range.
Backlight Key
The Graphic LCD display may be viewed with or without the backlight. Depressing any key will activate
the backlight. However, since the backlight will drain the battery if left on, it will automatically shut off
after a user programmable delay when running on battery power.
The key is provided to toggle the backlight on or off at any time.
GMC-I M
e
Functio
n
There ar
e
the keys
indicate
s
NOTE:
O
ECG W
a
The mic
r
to a D/A
through
r
e
sstechnik
G
n
Keys
e
five
vary depe
n
s
its current
O
nly functio
n
a
veforms
r
oprocesso
r
converter,
w
r
esistor net
w
G
mbH
keys t
h
n
ding on th
e
meaning.
n
s that are
r
has store
d
w
hich gene
w
orks, dev
e
h
at are use
d
e
current s
c
a
vailable t
o
Sample
d
in its mem
rates an a
c
e
loping the
d
to provide
c
reen. The
s
o
the user
w
Function Ke
y
m
ory all of t
h
c
curate ana
appropriat
e
general o
p
s
ection of t
h
w
ill be visibl
e
y
Labeling
h
e digitalize
d
log repres
e
e
signals o
n
p
erational c
o
h
e screen j
u
e
at any gi
v
d
wavefor
m
ntation. Th
e
n
the output
o
ntrol. The
u
st above t
h
v
en time.
m
s. It sends
e
wavefor
m
terminals.
SECULIFE
functions o
f
h
e key
the wavef
o
m
is then se
n
19
DF
BASE
f
o
rms
n
t
20 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
Universal Patient Lead Connectors
The 10 Universal Patient Lead Connectors allow for 12 lead ECG simulations. AHA and IEC color-
coded labels are located on the face of the unit to aid in connecting the corresponding U.S. and
International Patient Leads.
AHA Label
IEC Label
Description
RA R
Right Arm
LA
L
Left Arm
RL
N
Ri
g
ht Le
g
(reference or ground)
LL
F
Left Leg
V Leads
(
V1-V6
)
V1
C1
(U.S. and Canada)
also referred to as pericardial,
V2
C2
precordial or unipolar chest
V3
C3
leads
V4
C4
V5
C5
V6
C6
Chest Leads (C1-C6)
(International)
GMC-I Messtechnik GmbH 21
SECULIFE DF
BASE
High Level Output (+)
A high level ECG output signal (200 X Amplitude Setting) is available on the RCA jack located on the
rear of the unit.
Serial Port
A female 9-pin D-Sub connector is provided for the connection of the unit to a PC or laptop serial port (e.g.
Com 1). This link is then used for either remote control or flash downloading of software upgrades.
Parallel Port
A female 25-pin D-Sub connector is provided for the connection of a printer via a Centronics parallel
interface.
Oscilloscope Output
A BNC connector is provided to connect an oscilloscope to the unit. This output is a 200:1 attenuated
version of the input to the Defibrillator Plates.
22 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
Power Switch
A rocker switch is provided on the rear of the unit to turn the power on and off.
Power Supply
The unit utilizes two 9 Volt Alkaline Batteries in the bottom battery compartments. When the unit
detects a LOW BATTERY condition (10% Battery Life), a warning window will appear once per minute
to alert the user.
Battery Eliminator
The unit has a 2.1 mm micro jack for connecting a 10-Volt AC battery eliminator. The adapter will
power the unit, but will not charge the battery.
GMC-I M
e
When th
displaye
d
FUNCTI
O
input of
g
begin a t
The def
a
to 1000
J
The follo
w
e
sstechnik
G
e SECULI
F
d
. This scr
e
O
N KEYS.
g
reater tha
n
est.
a
ult configu
r
J
oules to b
e
w
ing is a s
a
G
mbH
D
F
E DF
BASE
e
en shows
All defibrill
n
100 Volt
s
r
ation is th
e
e
analyzed.
a
mple scre
e
D
EFIBR
is first po
w
the curren
t
ator tests
a
on the De
f
e
High Ran
g
e
n for this
m
ILLATO
w
ered up,
t
t
CONFIG
U
a
re run fro
m
f
ibrillator P
l
g
e Defibrill
a
m
ode:
MAIN
S
R ANA
L
t
he Defibril
U
RATION,
t
m
the MAI
N
l
ates (20 V
o
a
tor mode.
T
S
CREE
N
L
YZER
l
ator Analy
z
t
he TEST
R
N
SCREE
N
o
lts in Low
T
his mode
N
y
zer MAIN
R
ESULTS
a
N
. When th
e
Range), it
allows for
a
SECULIFE
S
CREEN
w
a
nd the av
a
e
unit dete
c
will autom
a
a
wavefor
m
23
DF
BASE
w
ill be
a
ilable
c
ts an
a
tically
m
of up
24
SECULIF
The
allows fo
ranges.
T
The follo
w
E DF
BASE
key
m
r wavefor
m
T
he lower r
a
w
ing is a s
a
m
ay be us
e
m
s up to 50
J
a
nge simpl
y
a
mple scre
e
e
d to toggl
e
J
oules to b
e
y
provides
f
e
n for this
m
e
the unit
t
e
analyzed
.
f
or a higher
m
ode:
t
o the Low
.
The Defib
r
resolution
f
Range D
e
r
illator Anal
y
f
or pulses
w
GMC
-
e
fibrillator
m
yzer works
w
ith smalle
r
-
I Messtech
n
m
ode. This
the same i
n
r
amplitude
s
n
ik GmbH
mode
n
both
s
.
GMC
-
The
C
RAN
G
The
f
This
s
STA
T
This l
ECG
This
l
ECG
AMP
This
chan
g
-
I Messtech
n
C
ONFIGU
R
G
E
f
irst line di
s
s
etting ma
y
T
US
ine provid
e
ine display
s
WAVEFO
R
line displa
y
g
ed in the
E
n
ik GmbH
R
ATION se
c
s
plays the
r
y
be chang
e
e
s informati
o
s
the selec
t
R
MS scree
n
y
s the amp
E
CG WAV
E
C
c
tion of the
M
r
ange valu
e
e
d using th
e
o
n about th
e
t
ion that is
a
n
.
litude that
E
FORMS s
c
C
ONFIG
M
AIN SCR
E
e
for the p
u
e
k
e
current st
a
ctive on t
h
has been
s
c
reen.
URATI
O
E
EN displa
y
u
lse. It may
k
ey.
t
atus of the
h
e ECG ter
m
s
elected fo
r
O
N
y
s the curr
e
be either
1
analyzer.
m
inals. Thi
s
r
the ECG
e
nt setup o
f
1
000 Joule
s
s
setting m
a
terminals.
T
SECU
L
f
the unit.
s or 50 Jo
u
a
y be chan
g
This settin
g
2
5
IFE DF
BASE
u
les max.
g
ed in the
g
may be
5
26
SECULIF
The TE
S
continue
NOTE:
T
Defibrilla
NOTE:
T
ENERG
Y
This line
PEAK V
This line
PEAK I
This line
E DF
BASE
S
T RESUL
T
to be displ
a
T
he unit aut
o
tor Plates (
T
est results
Y
displays th
displays th
displays th
T
S section
o
a
yed until t
h
o
matically
s
20 Volts in
are immed
i
e total ene
r
e peak volt
a
e peak cur
r
TE
o
f the MAIN
h
e power is
s
tarts a test
Low Rang
e
ately sent
t
r
gy of the l
a
a
ge of the l
r
ent of the l
a
ST RE
S
SCREEN
d
s
turned off,
when it se
e
e
).
t
o the print
e
a
st pulse.
ast pulse.
a
st pulse.
S
ULTS
d
isplays th
e
another te
s
e
s a voltag
e
e
r port as s
o
e
results of
t
s
t is run or
t
e
greater th
o
on as the
d
GMC
-
t
he last pul
s
t
he range i
s
h
an 100 Vol
d
ata is avai
-
I Messtech
n
s
e. It will
s
changed.
t
s on the
lable.
n
ik GmbH
GMC-I Messtechnik GmbH 27
SECULIFE DF
BASE
DELAY
This line normally displays the delay from the peak of the R wave until the start of the Defib Energy
pulse. The line is replaced by the CHARGE TIME if this test has been run (see START CHARGE
TIMER SCREEN for more information).
CHG TIME
This line displays if the Charge Timer has been run. It shows the time required to charge the Device
Under Test (DUT). This test is started with the key.
28
SECULIF
The FU
N
below th
features.
ECG W
A
This key
PLAYB
A
This ke
y
pulse m
a
START
C
This key
charge ti
PRINT
H
This key
MORE
K
These k
e
E DF
BASE
N
CTION K
E
h
e display.
A
VEFORM
S
enters the
A
CK LAST
y
enters th
e
a
y be viewe
C
HARGE
T
brings up
me for the
d
H
EADER
sends the
R
K
EYS
e
ys toggle
b
E
YS sectio
n
These ke
y
S
ECG WAV
E
PULSE
e
PLAYBA
C
d and sent
T
IMER
the CHAR
G
d
efibrillator
.
R
eport He
a
b
etween th
e
F
U
n
of the MA
y
s allow fo
r
E
FORMS s
c
C
K LAST
P
out.
G
E TIMER
.
a
der to the
p
e
Primary a
n
U
NCTI
O
IN SCREE
N
r
navigatio
n
creen whe
r
P
ULSE scr
e
screen an
p
rinter.
n
d Second
a
O
N KEY
S
N
displays
n
to suppo
r
r
e all ECG
p
e
en where
d starts th
e
a
ry Functio
n
S
t
he current
r
ting scree
n
Pr
i
S
e
p
arameters
a graphic
a
e
pre-warn
n
Keys.
GMC
-
functions
o
ns and ini
t
i
mary Functi
e
condary Fu
n
are set.
a
l represen
timer. It is
-
I Messtech
n
o
f the keys
t
iation of s
p
on Keys
n
ction Keys
t
ation of t
h
used to t
e
n
ik GmbH
found
p
ecific
h
e last
e
st the
GMC-I Messtechnik GmbH 29
SECULIFE DF
BASE
AUTO SEQUENCES
This key brings up the AUTO SEQUENCE MENU, which is used to view or run the Auto Sequences
stored in the unit.
SELF TEST WAVEFORM
This key sends an internal test pulse to the unit, allowing for the display of the results to give an
indication that the system is working properly.
SECULIFE DF
BASE
SETUP
This key brings up the SYSTEM CONFIGURATION SCREEN, which allows for adjusting the various
system configuration parameters.
30
SECULIF
E
The SE
C
Pressing
that is u
s
The follo
w
ECG GRO
U
Disable
d
NSR
AED
A
rrhythmi
a
Performa
n
E
DF
BASE
C
ULIFE DF
B
the
s
ed for the
E
w
ing is a s
a
U
P
d
None
30,40,
4
100,1
2
180,2
0
260,2
8
A
syst
o
Coars
e
Fine V
f
Multifo
Multifo
Polyfo
c
Polyfo
c
Supra
V
Vfib
A
fib
Secon
d
RBBB
PAC
a
s
PVC
E
PVC
S
PVC
R
MF P
V
Bigem
i
Run o
f
Vtach
0.125,
n
ce
2, 2.5
H
0.1,0.
2
00 Hz
30, 60
,
E
C
B
ASE
ECG o
u
key fr
o
E
CG outpu
t
a
mple of th
e
WAVEFO
R
4
5,60,80,90,
2
0,140,160,
0
0,220,240,
8
0,300 BPM
o
le
e
Vfib
f
ib
cal Vtach 1
4
cal Vtach 1
6
c
al Vtach 14
c
al Vtach 16
V
ent Tach 9
0
d
Deg Block
E
arly
S
TD
R
on T
V
C
i
ny
f
5 PVC
2 Hz Squar
e
H
z Triangle
2
,0.5,5,10,40
Sine
,
120 BPM
P
C
G WA
V
u
tput can b
e
o
m the MA
I
t
.
e
ECG wav
e
M
4
0
6
0
0
0
0
e
,50,60,1
P
ulse
V
EFOR
M
e
connecte
d
IN SCREE
N
eform confi
M
S SCR
d
in 3, 5 or
N
will allow
guration s
c
EEN
12 lead co
n
the user to
reen:
A
Lead I 0.
3
Lead I 0.
7
Lead I 1.
0
Lead I 1.
4
GMC
-
n
figuration
s
configure t
AMPLITUD
E
35 mV Lea
d
70 mV Lea
d
05 mV Lea
d
4
0 mV Lead
-
I Messtech
n
s
.
he wavefor
E
II 0.5 mV
II 1.0 mV
II 1.5 mV
II 2.0 mV
n
ik GmbH
m
GMC-I Messtechnik GmbH 31
SECULIFE DF
BASE
The ECG Group, Waveform and Amplitude can be selected using to highlight the
parameter and using to open a drop down menu of all the options for the highlighted
parameter.
Use to scroll to the desired option. Then is used to accept the new setting.
The key can be used to return to the ECG waveform configuration screen without making a new
selection.
The key is used to return to the MAIN SCREEN.
32 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
The following is a brief description of how the SECULIFE DF
BASE
simulates the available Arrhythmias:
Abbreviation Arrhythmia Description
Irregular waveform with no real
Vent Fib – Fine
Ventricular Fibrillation
P-wave or clear R-R interval and a
low signal level
(Continuous)
Atrial Fib
A
bsence of P-wave, irre
g
ular P-R
Atrial Fibrillation
interval rate and a high level signal
(Continuous)
80 BPM with increasin
g
2
nd
Deg Heart
Second Degree Heart Block
P-R interval for four beats
Block
(160
,
220
,
400
,
470
ms
)
followed by a P wave without a QRS
(Continuous)
Rt Bundle
80 BPM with Normal P-wave and P-
Right Bundle Branch Block R interval but wider QRS complexes
Branch Block
(Continuous)
NSR of 80 BPM with Periodic
PAC
Premature Atrial Contraction
Abnormal 25% early P waves
(PAC, 7 NSR)
(Continuous)
NSR of 80 BPM with periodic left
PVC Early
Early Type 1
focus premature ventricular beats
with 33% premature timing
Premature Ventricular Contraction
(PVC Type 1, 9 NSR)
(Continuous)
NSR of 80 BPM with periodic left
PVC Std
Standard Type 1
focus premature ventricular beats
with 20% premature timing
Premature Ventricular Contraction
(PVC Type 1, 9 NSR)
(Continuous)
NSR of 80 BPM with periodic left
focus premature ventricular beats
PVC R on T
R on T Type 1 with 65% premature timing, placing R
Premature Ventricular Contraction on the previous T
(PVC Type 1, 9 NSR)
(Continuous)
Multifocal
NSR of 80 BPM with T
y
pe 1 and
Multifocal Type 2 PVCs (PVC Type 1, 2 NSR,
PVCS
Premature Ventricular Contraction PVC Type 2, 2 NSR)
(Continuous)
GMC-I Messtechnik GmbH 33
SECULIFE DF
BASE
Abbreviation Arrhythmia Description
Bigeminy
Bigeminal Rhythm
NSR of 80 BPM with every othe
r
beat a Type 1 PVC
(Continuous)
NSR of 80 BPM with periodic
g
roup
Run of 5 PVCs
Run of 5 Premature Ventricular of 5 Type 1 PVCs
Contractions (5 PVC Type 1, 36 NSR)
(Continuous)
Vent Tach
160 BPM, No P-wave,
Ventricular Tachycardia Beats similar to Type 1 PVC
(Continuous)
34
SECULIF
The SE
C
accesse
d
playbac
k
internall
y
by a tim
e
In playb
a
and the
H
The scal
e
The
This key
The
This key
E DF
BASE
C
ULIFE DF
d
by pres
s
k
allows th
e
y
at 0.1 ms
e
factor of 2
a
ck mode, t
h
H
igh Level o
e
shown o
n
ke
y
replaces t
h
ke
y
replaces t
h
PLAY
B
BASE
can di
s
ing the
e
user to vi
e
intervals. T
00.
h
e samples
utput. The f
o
n
the scree
n
y
can be us
h
e
y
can be us
e
h
e
B
ACK L
A
s
play a gr
a
e
w the Def
i
he PLAYB
A
are shown
o
llowing is
a
n
is automa
t
ed to paus
e
key wh
e
e
d to play (
c
key.
A
ST PU
L
a
phical rep
r
key from
i
brillator pu
A
CK LAST
on the dis
p
a
sample of
t
ically adju
s
e
the scre
e
e
n a pulse i
s
c
ontinue) t
h
L
SE SC
R
r
esentation
the Defibr
i
lse in a ti
m
PULSE SC
p
lay and se
n
the wavefo
r
s
ted to pro
v
e
n at any p
o
s
being pla
y
h
e wavefor
m
R
EEN
of the last
i
llator Anal
m
e-expande
REEN sho
w
n
t out the E
C
r
m that is sh
ide the ma
x
o
int while a
y
ed back.
m
if it has b
e
GMC
-
pulse. Thi
s
yzer MAI
N
e
d form. Sa
w
s these s
a
CG leads,
D
h
own in the
d
x
imum res
o
pulse is b
e
e
en pause
d
-
I Messtech
n
s
screen
m
N
SCREEN
m
ples are
s
a
mples exp
a
D
efibrillator
d
isplay:
o
lution avail
a
e
ing played
d
.
n
ik GmbH
m
ay be
. The
s
tored
a
nded
Plates
a
ble.
back.
GMC-I Messtechnik GmbH 35
SECULIFE DF
BASE
The key starts a playback of only the first 20 ms of the waveform.
The key starts a playback of the entire 100 ms of the waveform.
At any time, the key or key can be depressed to return to the
MAIN SCREEN.
36
SECULIF
A special
Device U
charge ti
defibrilla
t
When th
e
The follo
w
E DF
BASE
timer has
b
nder Test (
D
ke
y
me, a Pre-
W
t
or charge
s
e
timer rea
c
w
ing is an
e
STAR
T
b
een incorp
o
D
UT). The
S
y
from the M
A
W
arning C
o
s
hould be i
n
c
hes zero,
a
e
xample of
T
CHA
R
o
rated into t
h
S
TART CH
A
A
IN SCRE
E
o
untdown p
e
n
itiated. Th
e
a
beep will
s
the count
u
R
GE TIM
h
e SECULI
F
A
RGE TIME
R
E
N. To sync
h
e
riod is sta
r
e
following
i
s
ound and
t
u
p timer:
ER SC
R
F
E DF
BASE
t
o
R
SCREEN
h
ronize the
r
ted. When
i
s an exam
p
t
he charge
R
EEN
o
analyze th
can be acc
e
c
harge tim
e
the timer r
e
p
le of the c
o
timer will b
e
GMC
-
h
e charging
c
e
ssed by pr
e
e
r with the d
e
e
aches zer
o
o
untdown t
i
e
gin counti
n
-
I Messtech
n
c
ircuit of th
e
e
ssing the
e
fibrillato
r
o
, the
i
mer:
n
g up.
n
ik GmbH
e
GMC-I M
e
The DU
T
timer will
as the ti
m
At any ti
m
MAIN S
C
e
sstechnik
G
T
should b
e
automatic
a
m
e require
d
m
e, the
C
REEN.
G
mbH
e
discharg
e
a
lly stop. T
h
d
to charge
t
key
e
d as soon
h
e display
w
t
he DUT:
can be de
p
as it beco
m
w
ill show th
e
p
ressed to
e
m
es charg
e
e
results of
e
nd the tim
e
e
d. When t
h
the Defibril
e
r and retur
h
e DUT is
lator pulse
C
R
r
n to the
SECULIFE
D
discharge
d
analysis a
s
C
harge Time
r
R
esults
37
D
F
BASE
d
, the
s
well
r
38
SECULIF
The SE
C
that is di
s
is availa
b
The stat
u
E DF
BASE
C
ULIFE DF
B
s
charged i
n
b
le. The he
a
u
s line of th
B
ASE
provid
e
n
to the unit.
a
der is sen
t
e configura
PRI
N
e
s a heade
Test resul
t
t
by pressi
n
tion sectio
n
N
T HEA
D
e
r for recor
d
t
s are imm
e
n
g the
n
will indica
t
D
ER
d
ing test d
a
e
diately sen
key fr
o
t
e that the
h
ta as well
a
t to the pri
n
o
m the MAI
h
eader has
GMC
-
a
s the res
u
n
ter port as
N SCREE
N
been sent
t
-
I Messtech
n
u
lts of each
soon as th
e
N
.
t
o the print
e
n
ik GmbH
pulse
e
data
e
r.
GMC-I Messtechnik GmbH 39
SECULIFE DF
BASE
The following is the print header and sample data that are used for the Defibrillator Analyzer mode.
Gossen Metrawatt
SECULIFE DF
BASE
Defibrillator Analyzer
SECULIFE DF
BASE
Serial Number:
Dut Manufacturer:
Dut Model:
Dut Serial Number:
Technician:
Location:
Date:
Comments:
SECULIFE DF
BASE
Measurements:
NOTE: Printing the header also resets the test number printed on the data sheet.
NOTE: In the test results, the user must manually write the power setting of the DUT.
40
SECULIF
The SE
C
working
properly.
SCREE
N
A
fter the
SCREE
N
will provi
d
Joules
w
The follo
w
The follo
w
graphica
E DF
BASE
C
ULIFE DF
B
The Self
T
N
.
waveform
h
N
and the P
de a wavef
o
w
hen config
u
w
ing is an
e
w
ing is an
e
l represent
a
B
ASE
has bu
i
T
est Wavef
o
h
as been s
e
LAYBACK
o
rm that is
u
red for the
e
xample of
e
xample of
a
tion of the
SELF
lt in test w
a
o
rm may be
e
nt, the res
LAST PUL
S
a
pproxima
t
Low Rang
e
the MAIN
S
the PLAY
B
Self Test
W
TEST
W
a
veforms th
sent by pr
e
s
ults will be
S
E SCREE
t
ely 125 Jo
u
e
.
S
CREEN w
B
ACK LAS
T
W
aveform:
W
AVEF
O
a
t will give
e
ssing the
reflected in
N. The Sel
f
u
les when
c
ith the resu
T
PULSE S
C
O
RM
a
n indicati
o
the test re
s
f
Test Wav
e
c
onfigured f
o
lts of the S
e
C
REEN, sh
o
GMC
-
o
n that the
s
key from t
h
s
ults sectio
e
form is no
t
f
or the High
e
lf Test Wa
o
wing a
-
I Messtech
n
s
ystem is
e MAIN
n of the M
A
t
calibrated,
Range an
d
veform:
n
ik GmbH
A
IN
but
d
5
GMC-I Messtechnik GmbH 41
SECULIFE DF
BASE
This page intentionally left blank.
42
SECULIF
The SE
C
primary
m
voltage
a
The hu
m
defibrilla
t
resistor t
E DF
BASE
A
(
D
C
ULIFE D
F
m
easure of
a
nd current
m
an body h
a
t
or testing.
T
o simulate
a
RUN
N
WA
R
ll conne
c
before
c
D
UT) to
t
occur
Do not c
dir
e
F
BASE
will a
n
the output
as well as
t
a
s characte
r
T
he SECU
L
a
human b
o
ING
A
D
R
NING
c
tions t
o
c
onnecti
t
he Anal
y
if the pa
t
t
esting
w
o
nnect
a
e
ctly to t
INT
R
n
alyze the
is the Ener
g
t
he pulse ti
m
r
istic imped
L
IFE DF
BAS
E
o
dy. It is si
z
D
EFIBRI
- CO
N
o
patient
s
ng the
D
y
zer. A
s
tient is
c
w
ith the
A
a
ny lead
s
t
he Anal
y
R
ODUC
T
pulse outp
g
y that it c
o
m
ing with r
e
ance that
m
E
has a lar
g
z
ed to acce
p
LLATO
R
N
NECT
I
s
must
b
D
evice U
n
s
erious
h
c
onnect
e
A
nalyze
r
s
from th
e
y
zer or D
T
ION
ut of a m
o
o
ntains. Ot
h
e
spect to th
m
ay vary, b
u
g
e internal
5
p
t repeated
R
TEST
I
ONS
b
e remo
v
n
der Te
s
h
azard
m
e
d when
r
.
e
patient
U
T.
nophasic
o
h
er informa
t
e R-wave.
u
t 50 ohms
5
0 ohm non
pulses at t
h
GMC
-
v
ed
s
t
m
ay
o
r biphasic
t
ion deals
w
is used for
-inductive,
he maximu
-
I Messtech
n
defibrillato
r
w
ith the ma
x
comparati
v
high-powe
r
m energy l
e
n
ik GmbH
r
. The
x
imum
v
e
r
e
vels.
GMC-I Messtechnik GmbH 43
SECULIFE DF
BASE
The energy contained in a pulse is determined mathematically based on the fact that the energy is
defined as the integral of the power curve. The following formulas describe the basic computation:
Energy = E = P dt
Power = P = V
2
/ R => E = V
2
/ R dt = V
2
dt / R
This computation is implemented digitally by taking timed samples of the voltage every 100 µsec for 100
msec (1000 readings). Each value is then squared and divided by the resistance (50 ohms). The sum of
these 1000 values times 10 is then the Energy in Joules (Watt Seconds) contained in the pulse.
44
SECULIF
The setu
example
(1)
C
T
(2) T
(3) T
a
d
(4)
S
m
(5)
P
ri
g
E DF
BASE
p for a Defi
we will as
s
Thi
s
t
h
int
e
for
e
ma
n
C
onnect EC
T
he connec
t
T
urn on the
S
T
he unit will
dult testing
NOTE
:
voltag
e
Defibri
S
elect “Vent
m
V. This is
n
P
lace the D
e
g
ht and th
e
brillation T
e
s
ume a sta
n
s
sectio
n
h
e user
w
e
nded to
e
very D
e
n
ufacture
the c
o
G leads to
t
ors are ma
r
S
ECULIFE
come up i
n
.
:
If it is desi
e
of 1000 V
llator” mod
e
ricular Fibri
n
ecessary
f
e
fibrillator
P
e
STERNU
M
DEFIB
R
e
st is depe
n
n
dard defib
r
W
A
n
is prov
i
w
ith the
S
provide
t
e
fibrillat
o
r’s man
u
o
rrect te
s
the corres
p
r
ked with b
o
DF
BASE
.
n
the “High
R
rable to ru
n
o
lts or less
,
e
using the
llation” fro
m
o
r most au
t
P
addles on
M
is on the l
R
ILLATI
O
n
dent on th
e
r
illator with
5
A
RNI
N
i
ded as
a
S
ECULI
F
t
he nece
o
r. The u
s
u
al for e
a
s
t proce
d
p
onding un
o
th the AH
A
R
ange Defi
n
a test at 5
0
,
the unit m
a
k
m
the ECG
W
t
omatic defi
the SECU
L
l
eft.
O
N TES
T
e
physical
h
5
lead EC
G
N
G
a
guide t
o
F
E DF
BAS
E
ssary te
s
s
er must
a
ch DUT
t
d
ure to f
o
iversal con
A
and Inter
n
brillator” m
o
0
Joules or
a
y be chan
g
k
ey.
W
AVEFO
R
brillators.
L
IFE DF
BA
S
T
h
ardware in
v
G
.
o
familia
r
E
. It is no
s
t seque
n
consult
t
o deter
m
o
llow.
n
ector on t
h
n
ational col
o
o
de. This r
a
less with a
g
ed to the
M SCREE
N
E
contact
p
GMC
-
volved. Fo
r
r
ize
o
t
n
ce
the
m
ine
he SECUL
o
r codes.
a
nge is use
d
peak
Low Rang
e
N
with an a
m
p
lates. The
-
I Messtech
n
r
the sake
o
I
FE DF
BASE
d
for norm
a
e
m
plitude of
APEX is o
n
n
ik GmbH
o
f this
.
a
l
1
n
the
GMC
-
o
o
(
6
(
7
-
I Messtech
n
NOTE: Re
v
o
r error in t
o
scilloscop
e
6
) Holding t
SECULI
F
O
M
7
) The SE
C
load and
and displ
a. T
h
a
t
b.
Af
e
x
T
h
c.
At
n
ik GmbH
v
ersing the
he energy
r
e
output an
he paddles
F
E DF
BASE
.
O
bserve
a
M
anufact
u
C
ULIFE DF
B
begin taki
n
ay the res
u
he power p
t
tenuation
w
f
ter the co
m
x
pansion (
2
he signal l
e
t the same
paddles wil
r
eading. H
o
d the play
b
firmly in pl
a
a
ll preca
u
rer wh
e
B
ASE
will aut
o
n
g readings
.
u
lts.
ulse is ava
i
w
hen in low
m
putation, t
h
2
00 times sl
e
vel is 1 m
V
time, the t
e
l not cause
wever, it w
i
b
ack wavef
o
a
ce, charg
e
WAR
N
utions n
e
n using
o
matically
s
.
After the
s
lable at th
e
range and
h
e pulse is
ower) on b
o
V
per 1000
V
e
st results a
any dama
g
i
ll cause th
e
o
rm to be in
e
the Defib
r
N
ING
oted by
the Defi
s
ense the v
o
s
ampling is
e
oscillosco
p
1000:1 sig
n
automatic
a
o
th the EC
G
V
olts on Le
a
a
re sent to t
h
g
e to the u
n
e
polarity o
f
verted.
r
illator and
d
the Defi
b
brillator
.
o
ltage rise
a
done (100
m
p
e output i
n
n
al attenua
t
a
lly played
b
G
leads an
d
a
d 1.
h
e printer.
n
it
f
the
d
ischarge it
b
rillator
.
a
cross the
i
m
s) the uni
t
n
real time
a
t
ion when i
n
b
ack at a 2
0
d
the Paddl
e
SECULI
F
t
into the
i
nternal 50
t will comp
u
a
t 200:1 sig
n
high rang
0
0:1 time b
a
e
plates.
4
5
F
E DF
BASE
o
hm
u
te
nal
e.
a
se
5
46 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
(8) The Status line will change to indicate the various steps as they are being done.
(9) At the end of the process the results are continuously displayed in the Test Results section
of the MAIN SCREEN. They will remain there until another test is performed, the range is
changed or the power is turned off.
(10) The user may repeat the playback of the waveform at any time by changing to the
PLAYBACK LAST PULSE SCREEN using the key. In this screen the pulse may
be viewed in 20 msec segments and paused for review.
NOTE: The pulse is sent to the ECG and Paddle outputs at the same time
it is being displayed on the screen.
GMC-I Messtechnik GmbH 47
SECULIFE DF
BASE
This page intentionally left blank.
48
SECULIF
A
Cardio
SECULI
F
between
pulse ba
s
(1)
C
T
(2) T
(3) T
a
d
E DF
BASE
version Te
s
F
E DF
BASE
c
the R-wav
e
s
ed on a s
p
This
th
inte
n
for e
v
det
e
C
onnect EC
T
he connec
t
T
urn on the
S
T
he unit will
dult testing
NOTE
:
voltag
e
Defibri
s
t is simply
c
ontinuousl
y
e
and the p
u
p
ecific dela
y
section
e user
w
n
ded to
p
v
ery De
f
manufa
c
e
rmine t
h
G leads to
t
ors are ma
r
S
ECULIFE
come up i
n
.
:
If it is desi
e
of 1000 V
llator” mod
e
CAR
D
an energy
t
y
monitors
f
u
lse. In Ca
r
y
after the
R
W
A
is provi
d
w
ith the
S
p
rovide t
f
ibrillato
r
c
turer’s
m
h
e corre
c
the corres
p
r
ked with b
o
DF
BASE
.
n
the “High
R
rable to ru
n
o
lts or less
,
e
using the
D
IOVER
S
t
est with s
p
f
or the R-w
a
r
dioversion
R
-wave.
A
RNIN
d
ed as a
S
ECULIF
he nece
s
r
. The u
s
m
anual
f
ct test p
p
onding un
o
th the AH
A
R
ange Defi
n
a test at 5
0
,
the unit m
a
k
S
ION T
E
p
ecial attent
a
ve timing
a
testing, th
e
G
guide t
o
E DF
BAS
E
s
sary te
s
s
er must
f
or each
rocedur
e
iversal con
A
and Inter
n
brillator” m
o
0
Joules or
a
y be chan
g
k
ey.
E
ST
ion being g
a
nd display
e
Defibrillat
o
o
familia
r
E
. It is n
o
s
t seque
consult
DUT to
e
to foll
o
n
ector on t
h
n
ational col
o
o
de. This r
a
less with a
g
ed to the
GMC
-
iven to the
y
s, if possib
l
o
r is set to
d
rize
o
t
e
nce
the
o
w.
he SECUL
o
r codes.
a
nge is use
d
peak
Low Rang
e
-
I Messtech
n
timing. Th
e
l
e, the dela
y
d
eliver a
I
FE DF
BASE
d
for norm
a
e
n
ik GmbH
e
y
.
a
l
GMC-I M
e
(4)
S
W
(5)
S
(6)
P
ri
g
(7)
H
S
e
sstechnik
G
S
elect the d
e
W
AVEFOR
M
NOTE
:
S
et the Defi
b
P
lace the D
e
g
ht and th
e
NOTE:
error in
oscillo
s
H
olding the
p
S
ECULIFE
D
O
b
M
a
G
mbH
e
sired EC
G
M
SCREEN
:
The selec
t
b
rillator to
S
e
fibrillator
P
e
STERNU
M
Reversing
the energ
y
s
cope outp
u
p
addles fir
m
D
F
BASE
.
b
serve
a
a
nufact
u
G
Wavefor
m
.
t
ed wavefo
r
S
ynchroniz
e
P
addles on
M
is on the l
the paddle
s
y
reading. H
u
t and the p
m
ly in plac
e
ll preca
u
u
rer whe
n
m
and Ampli
t
r
m must co
n
e
d Cardiov
e
the SECU
l
eft.
s
will not c
a
H
owever, it
w
layback w
a
e
, charge th
WARN
u
tions n
o
n using
t
t
ude to be
t
n
tain a QR
S
e
rsion mod
e
LIFE DF
BA
S
a
use any d
a
w
ill cause t
h
veform to
b
e Defibrilla
t
ING
o
ted by
t
t
he Defi
b
t
ested from
S
complex.
e
.
S
E
contact
p
a
mage to th
e
h
e polarity
o
b
e inverted.
t
or and dis
c
t
he Defi
b
b
rillator.
the choice
p
lates. The
e
unit or
o
f the
c
harge it int
b
rillator
SECULIFE
D
s on the E
C
APEX is o
o
the
49
D
F
BASE
C
G
n the
50 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
(8) The SECULIFE DF
BASE
will automatically sense the voltage rise across the internal 50 ohm
load and begin taking readings. After the sampling is done (100 ms) the unit will compute
and display the results.
a. The power pulse is available at the oscilloscope output in real time at 200:1 signal
attenuation when in low range and 1000:1 signal attenuation when in high range.
b. After the computation, the pulse is automatically played back at a 200:1 time base
expansion (200 times slower) on both the ECG leads and the Paddle plates. The signal
level is 1 mV per 1000 Volts on Lead 1.
c. At the same time, the test results are sent to the printer.
(9) The Status line will change to indicate the various steps as they are being done.
(10) At the end of the process the results are continuously displayed in the Test Results section
of the MAIN SCREEN. They will remain there until another test is performed, the range is
changed or the power is turned off.
NOTE: Special note should be made of the “Delay: xxx msec” line in the
results. This will show the delay between the peak of the R-wave and the
start of the Pulse.
GMC-I Messtechnik GmbH 51
SECULIFE DF
BASE
The user may repeat the playback of the waveform at any time by changing to the PLAYBACK LAST
PULSE SCREEN using the key. In this screen the pulse may be viewed in 20 msec
segments and paused for review.
NOTE: The pulse is sent to the ECG and Paddle outputs at the same time
it is being displayed on the screen.
52
SECULIF
The cha
r
Defibrilla
The SE
C
(1) T
(2) T
a
d
(3)
S
(4)
D
E DF
BASE
r
ging time
o
tor to char
g
C
ULIFE DF
B
Thi
t
int
e
for
ma
n
T
urn on the
S
T
he unit will
dult testing
S
et the Defi
b
D
epress the
o
f a Defibrill
a
g
e. It is use
d
B
ASE
provid
e
s sectio
n
t
he user
w
e
nded to
every D
e
n
ufactur
e
the c
o
S
ECULIFE
come up i
n
.
b
rillator to i
t
CHAR
G
a
tor is noth
d
to test th
e
e
s a simple
w
W
n
is prov
w
ith the
S
provide
e
fibrillat
o
e
r’s man
u
o
rrect te
s
DF
BASE
.
n
the “High
R
t
s maximu
m
key.
G
E TIM
E
ing more t
h
e
battery, c
h
way to star
t
W
ARNI
N
ided as
a
S
ECULI
F
the nec
e
o
r. The u
s
u
al for e
a
s
t proce
d
R
ange Defi
m
power set
E
TEST
h
an a meas
u
h
arging circ
t
and stop
t
N
G
a
guide t
o
F
E DF
BAS
E
e
ssary te
s
s
er mus
t
a
ch DUT
d
ure to f
o
brillator” m
o
ting.
u
rement of
uitry and c
a
he timer. It
o
familia
r
E
. It is n
o
s
t seque
t
consult
to deter
m
o
llow.
o
de. This r
a
GMC
-
the time re
q
a
pacitor.
also recor
d
rize
o
t
nce
the
m
ine
a
nge is use
d
-
I Messtech
n
q
uired for t
h
d
s the resul
t
d
for norm
a
n
ik GmbH
h
e
t
s.
a
l
GMC-I M
e
(5)
W
S
(6)
H
i
m
(7)
A
(8)
A
t
h
c
h
e
sstechnik
G
W
hile the Pr
e
ECULIFE
D
NOT
E
in the
oscill
o
H
olding the
p
m
mediately
A
s soon as
t
Ob
s
Ma
n
A
t the end o
f
h
e MAIN S
C
h
anged or
t
NOTE
:
“Chg
T
G
mbH
e
-Warning
C
D
F
BASE
cont
a
E
: Reversin
g
energy rea
d
o
scope out
p
p
addles fir
m
start charg
t
he DUT is
f
s
erve all
n
ufactur
e
f
the proce
s
C
REEN. Th
t
he power i
s
:
The last li
n
T
ime: xxx.x
s
C
ountdown i
s
a
ct plates. T
h
g
the paddl
e
d
ing. How
e
p
ut and the
m
ly in place
ing the Def
i
f
ully charg
e
W
precauti
e
r when
u
s
s the resul
t
e
y will rem
a
s
turned off
.
n
e in the T
e
s
ec”
s
running,
p
he APEX is
e
s will not
c
e
ver, it will
c
playback
w
e
, wait until
t
ibrillator.
e
d, dischar
g
W
ARNI
N
ons not
e
u
sing th
e
ts are conti
a
in there u
n
.
e
st Results
lace the De
f
on the righ
t
c
ause any
m
c
ause the p
o
w
aveform to
t
he Pre-W
a
g
e it into th
e
N
G
e
d by th
e
e
Defibr
i
nuously di
s
n
til another
section of
t
f
ibrillator P
a
and the S
T
m
age to the
o
larity of th
e
be inverte
d
a
rning Cou
n
e
SECULIF
E
e
Defibri
l
llator.
s
played in t
h
t
est is perf
o
t
he screen
w
a
ddles on th
e
T
ERNUM is
o
unit or err
o
e
d
.
n
tdown equ
a
E
DF
BASE
.
llator
h
e Test Re
s
o
rmed, the
r
w
ill show
SECULIFE
D
e
o
n the left.
o
r
a
ls zero an
d
s
ults sectio
n
r
ange is
53
D
F
BASE
d
then
n
of
54
SECULIF
The Sho
c
semiauto
Shock” b
a
E DF
BASE
c
k Advisory
A
matic Defib
r
a
sed on nat
EC
G
A
sy
s
Sup
Pol
y
Mul
t
Co
a
Fin
e
Pol
y
Mul
t
T
i
f
m
A
lgorithm T
r
illators. Th
e
ional and in
G
SIGNAL
S
s
tole
ra Ventricu
y
focal Vent
r
t
ifocal Vent
r
a
rse Ventric
e
Ventricula
y
focal Vent
r
t
ifocal Vent
r
T
his sec
t
the u
s
i
ntended
f
or ever
y
m
anufac
t
th
e
SH
A
L
est works
w
e
se circuits
l
t
ernational
g
SHOCK A
D
S
lar Tachyc
a
r
icular Tac
h
r
icular Tac
h
ular Fibrilla
t
r Fibrillatio
n
r
icular Tac
h
r
icular Tac
h
t
ion is p
r
er with t
h
to provi
y
Defibril
l
urer’s m
e
correc
t
OCK A
D
L
GORIT
H
w
ith the anal
y
l
ook at EC
G
g
uidelines.
T
D
VISORY
A
a
rdia @ 90
h
ycardia @
h
ycardia @
tion
n
h
ycardia @
h
ycardia @
WAR
N
r
ovided
a
h
e SEC
U
de the n
e
l
ator. Th
e
anual fo
r
t
test pr
o
D
VISOR
Y
H
M TES
T
y
sis and pr
o
G
waveform
s
T
he followin
A
LGORITH
BPM
140 BPM
140 BPM
160 BPM
160 BPM
N
ING
a
s a gui
d
U
LIFE DF
B
e
cessar
y
e
user m
r
each D
U
o
cedure
t
Y
T
o
mpting fun
c
s
and prom
p
g
table outli
M TEST
e to fam
i
B
ASE
. It i
s
y
test se
q
ust con
s
U
T to de
t
o follow.
GMC
-
c
tions on au
p
t the user t
o
nes these g
ACTION
No Shock
No Shock
No Shock
No Shock
Shock
Shock
Shock
Shock
iliarize
s
not
q
uence
s
ult the
t
ermine
.
-
I Messtech
n
t
omatic and
o
“Shock” o
r
uidelines:
n
ik GmbH
r
“No
GMC-I Messtechnik GmbH 55
SECULIFE DF
BASE
(1) Connect ECG leads to the corresponding universal connector on the SECULIFE DF
BASE
.
The connectors are marked with both the AHA and International color codes.
(2) Turn on the SECULIFE DF
BASE
.
(3) The unit will come up in the “High Range Defibrillator” mode. This range is used for normal
adult testing.
(4) Select the desired AED Waveform and Amplitude to be tested from the choices on the ECG
WAVEFORM SCREEN.
(5) Set the Defibrillator to analyze the ECG waveform in the automatic or semiautomatic mode.
(6) Observe and record the response of the Defibrillator to the various waveforms.
56
SEC
U
INPU
The “
rang
e
LOW
This
m
EXIT
I
The “
Mod
e
U
LIFE DF
BAS
T OVERL
O
Warning In
e
should be
BATTER
Y
m
essage in
I
NG AUTO
Exit Auto S
e
when
E
O
AD
put Overlo
a
checked t
o
Y
dicates tha
SEQUEN
C
S
equence T
e
is pu
s
a
d Check R
o
see if it s
h
t the batter
i
C
E TESTIN
G
e
st All Dat
a
s
hed. If the
ME
S
ange” mes
s
ould be ch
a
i
es are low
G
a
Will be Lo
s
data is ne
e
S
SAGES
s
age can d
i
a
nged to Hi
and shoul
d
s
t!” messa
g
e
ded, it sh
o
i
splay durin
gh Range
f
d
be replac
e
g
e will displ
a
uld be prin
t
G
M
g Defibrilla
t
f
or the curr
e
e
d.
a
y in the A
u
t
ed prior to
e
MC-I Messt
e
t
or testing.
T
e
nt Joule s
e
u
to Sequen
c
exiting.
e
chnik Gmb
H
T
he
e
tting.
c
ing
H
GMC-I M
e
The SY
S
Selected
paramet
e
setting.
T
selectio
n
The
The follo
w
P
B
A
T
B
P
S
e
sstechnik
G
S
TEM SET
U
using
e
r. The
T
he
n
.
key i
s
w
ing is a b
r
P
aramete
r
B
acklight Ti
m
A
uto Seque
n
T
ime
r
B
attery Life
P
ower up wi
S
oftware
G
mbH
U
P SCREE
N
to hig
h
keys
a
key can b
e
s
to return t
r
ief descrip
t
O
f
m
ed
1-
b
a
A
l
w
c
o
n
ce S
e
w
h
Di
w
a
p
o
S
e
th
u
n
C
u
S
e
Di
S
Y
N
allows fo
r
h
light the p
a
a
re used to
e
used to r
e
o
the MAIN
t
ion of the
p
f
f
A
lways
2
0 sec – T
h
a
cklight will
w
ays On –
o
ntrolled by
e
ts the dela
h
en the tes
t
splays curr
e
a
rning scre
e
o
wer down
a
e
lects the v
a
n
it is first tu
r
u
stom Defa
e
ttings).
splays curr
e
Y
STEM
r
the config
u
a
rameter a
n
o
edit the s
e
e
turn to the
N
SCREEN.
p
arameters
Descr
of
f
h
e elapsed
automatic
a
The backli
g
backlight
k
a
y between
t
passes.
r
ent life of t
h
e
n will app
e
a
utomatica
l
a
lues that
w
r
ned on. It i
s
a
ults, if use
d
r
ent softwa
r
SETUP
u
ration of t
h
n
d using
tting, then
configurati
o
and the av
a
i
ption
time after
w
a
lly turn off.
g
ht will be
m
ey)
A
uto Sequ
e
h
e batterie
s
e
ar. At 10%
l
ly.
w
ill be used
s
also use
d
d
. (See Po
w
r
e program.
h
e system
s
to all
o
is u
s
o
n screen
w
a
ilable ran
g
w
hich the
m
anually
e
nce tests
. At 5%, a
, the unit w
when the
to Set the
w
er Up
s
ettings. Th
e
o
w the edit
i
s
ed to acce
p
w
ithout mak
g
e of settin
g
R
a
Off, 1
A
lw
a
1-
2
5-
1
w
ill
(Rea
Defa
u
Cu
s
Set
C
De
(Rea
SECULIFE
e
settings
c
i
ng of the
p
t the new
ing a new
g
s:
a
nge
-20 sec,
a
ys On
2
0 sec
1
00%
d Only)
u
lt/Last/
s
tom/
C
ustom
f
aults
d Only)
57
DF
BASE
c
an be
58 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
This page intentionally left blank.
GMC-I M
e
The SE
C
“Power
U
Custom
s
DEFAU
L
If this op
t
on. Ran
g
ECG –
O
CUSTO
M
If this op
t
recall th
e
SET CU
R
The use
r
.
e
sstechnik
G
C
ULIFE DF
B
U
p With” pa
s
elections.
L
T
t
ion is sele
c
g
e – Defib,
H
O
utput Disa
b
M
t
ion is sele
c
e
m every ti
m
R
RENT AS
r
simply co
n
.
The curre
n
G
mbH
B
ASE
allows
t
rameter in
t
c
ted the foll
H
igh Rang
e
b
led
c
ted, the u
s
m
e the pow
e
CUSTOM
n
figures the
n
t configur
a
PO
W
t
he user to
t
he System
owing setti
n
e
mode
er may sa
v
e
r is turned
unit to the
a
tion is then
W
ER UP
tailor the s
e
Setup Me
n
n
gs will be
u
v
e a unique
on.
desired de
f
n
saved as
t
S
ETTIN
G
e
ttings that
n
u allows f
o
u
sed every
set of defa
u
f
ault conditi
t
he Custom
G
S
the unit will
r the selec
t
time the u
n
u
lt paramet
e
o
ns, select
s
Power up
v
l
have on P
t
ion of eith
e
n
it is turned
t
ers and th
e
s
this optio
n
v
alues.
SECULIFE
D
ower Up. T
e
r Default o
r
e
unit will
n
and pres
s
59
D
F
BASE
he
r
s
es
60 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
This page intentionally left blank.
GMC-I M
e
The SE
C
Sequen
c
test Defi
A
uto Se
q
Once co
serial int
e
The AU
T
key.
In this m
e
The
which wi
l
selected
enter th
program
m
failed b
a
A
uto Se
q
e
sstechnik
G
C
ULIFE D
F
c
es). The te
brillator, T
r
q
uence Pro
g
o
nfigured, t
h
e
rface.
T
O SEQUE
N
e
nu, the
ke
y
l
l allow the
test. The
e RUN
M
m
ed test a
a
sed upon
t
q
uence.
G
mbH
A
F
BASE
allow
s
sts are co
n
r
anscutane
o
g
ramming
s
h
e tests ar
e
N
CE SCR
E
key
y
can be us
e
user to vie
w
k
e
M
ODE whi
c
s well as i
t
he pre-pr
o
A
UTO S
E
s
the use
r
figured wit
h
o
us Pace
m
s
ection).
e
then do
w
E
EN is acce
s
a
re used t
o
e
d to enter
w
the progr
a
e
y will run t
h
c
h will ste
dentify wh
e
o
grammed
t
E
QUEN
C
r
run up t
o
h
an easy t
o
m
aker or b
o
w
nloaded t
o
ssed using
o
select the
the VIEW
M
a
mmed tes
t
he test and
p the tec
h
e
ther each
t
est limits
t
C
E FUN
o
50 pre-p
r
o
use PC p
o
th. (For p
r
o
the SEC
U
the
desired te
s
M
ODE
t
options of
h
nician th
r
step has
p
hat are pa
C
TION
r
ogrammed
r
ogram. Ea
r
ogrammin
g
U
LIFE DF
B
A
t.
the
r
ough the
p
assed or
r
t of each
d
sequenc
e
a
ch test can
g
Auto Se
q
A
SE
unit th
r
AUTO
S
LifePak 4
LifePak 5
LifePak 6
LifePak 6
S
LifePak 8
LifePak 9
LifePak 9
LifePak 1
0
LifePak 1
0
LifePak 1
0
HP 7866
0
HP XLP
M
Nihon Ko
h
Laerdal
H
Marquett
e
Zoll PD 2
0
Zoll M-S
e
Zoll AED
Blank Te
s
SECULIFE
D
e
s of tests
be config
u
q
uences, s
e
ough the
R
S
EQUENCE
S
S
P
P
PM
0
0
P
0
PM
0
A
M
h
den 7000
H
S 2000
e
1500PM
0
00
ries DSW
Plus
s
ts 20-50
61
D
F
BASE
(Auto
u
red to
e
e the
R
S232
S
62 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
The following table shows the possible test sequence with the details and options that can be selected
using the PC program:
Test
Description Fields Options
Defibrillator Test Sequence
Defib Energy Tests
Measures defibrillator
Steps 1-20
xxx Joules
Energy Level Limits 0-99%
discharge energy
VFIB ECG Output yes/no
Measures time
Do Test? yes/no
Maximum Energy Test
required for defibrillato
r
Ener
gy
Level Limits
xxx Joules
to charge to maximum
Max Allowed Char
g
e
x sec
energy Time
Cardioversion Tests
Measures
Steps 1-3 xxx Joules
Cardioversion Delay
Energy Level Limits 0-99%
Tests defibrillator
Steps Up to 10
ECG Performance Test
Waveform Outputs and
x Waveform Grou
p
ECG input
x Waveform
Amplitudes
Lead II = x.x mV
GMC-I M
e
The VIE
W
well as t
VIEW M
O
its confi
g
The follo
selected
:
NOTE: I
f
MODE.
DEFIBR
I
e
sstechnik
G
W
MODE
a
he test lim
i
O
DE are d
e
g
uration as
d
wing scree
:
f
any partic
u
I
LLATOR
E
G
mbH
a
llows the
u
i
ts that ide
n
e
termined
b
d
efined wit
h
ns are exa
m
u
lar test o
p
E
NERGY T
E
V
ser to look
n
tify a valid
b
y the Auto
h
the PC pr
o
m
ples of w
h
p
tion is disa
E
STS:
V
IEW M
at the test
d
or invalid
Sequence
o
gram.
h
at could b
bled using
ODE
configurati
test result.
selected o
n
e shown in
the PC Pr
o
T
e
E
n
V
F
o
n. Each t
e
The scree
n
n
the AUT
O
the VIEW
o
gram, it wi
l
e
st Settings
n
ergy Limit
s
F
IB Option
e
st setting
w
ns that are
O
SEQUEN
C
MODE if a
l
ll not be sh
s
SECULIFE
w
ill be sho
w
displayed
C
E SCREE
l test optio
n
own in the
63
DF
BASE
w
n, as
in the
N and
n
s are
VIEW
64
SECULIF
DEFIBR
I
DEFIBR
I
E DF
BASE
I
LLATOR
M
I
LLATOR
C
M
AXIMUM
E
C
ARDIOVE
E
NERGY
T
RSION TE
S
T
ESTS:
S
TS:
M
M
T
T
M
ax Energy
M
ax Energy
T
est Setting
s
T
est Limits
GMC
-
Test Limit
s
s
-
I Messtech
n
s
n
ik GmbH
GMC-I M
e
DEFIBR
I
NOTE:
T
e
sstechnik
G
I
LLATOR
E
T
he individu
G
mbH
E
CG PERF
O
al selected
O
RMANC
E
waveform
s
E
TEST:
s
are not di
s
W
s
played in t
h
W
aveform S
e
h
e VIEW M
O
e
lection
ODE.
SECULIFE
D
65
D
F
BASE
66
SECULIF
The RU
N
MODE a
configur
a
Running
semi-aut
o
individu
a
given te
s
SCREE
N
NOTE: I
f
MODE.
NOTE:
S
require t
h
The follo
w
E DF
BASE
N
MODE all
o
re determi
n
a
tion as de
f
an Auto S
e
omated pr
o
a
l tests. A p
r
s
t passes.
T
N
.
f
any partic
u
S
ome tests,
h
e user to
m
w
ing samp
l
o
ws the use
r
n
ed by the
A
f
ined with t
h
e
quence wil
o
cess that
w
r
ogramma
b
T
his timer is
u
lar test op
t
like Perfor
m
m
anually pr
o
l
e screen s
h
r
to run the
t
A
uto Seque
h
e PC prog
r
l provide a
w
ill provide
i
b
le timer is
p
set in the
A
t
ion is disa
b
m
ance Wa
v
o
gress thro
h
ows the c
o
RUN
M
t
est configu
r
nce select
e
r
am.
consistent,
i
mmediate
f
p
rovided to
A
uto Sequ
e
b
led using t
h
v
eforms, do
o
ugh the te
s
o
mmon ele
m
M
ODE
r
ation. The
s
e
d on the A
U
guided pr
o
f
eedback t
o
automatic
a
e
nce Timer
h
e PC Pro
g
not have q
s
t.
m
ents pres
e
s
creens that
U
TO SEQ
U
cedure for
t
o
the user if
a
lly progres
s
p
arameter
i
g
ram, it will
uantitative
a
e
nt during t
h
GMC
-
t
are displa
y
U
ENCE SC
R
t
esting equ
f
the DUT p
a
s
through t
h
i
n the SYS
T
not be sho
w
analyses a
n
he RUN M
O
-
I Messtech
n
y
ed in the R
U
R
EEN and i
ipment. Thi
a
sses or fa
i
h
e test whe
n
T
EM SETU
P
w
n in the R
U
n
d therefor
e
O
DE:
n
ik GmbH
U
N
ts
s is a
i
ls
n
a
P
U
N
e
GMC-I M
e
The follo
w
DEFIBR
I
e
sstechnik
G
w
ing scree
n
I
LLATOR
E
G
mbH
n
s may be
s
E
NERGY T
E
s
hown in th
E
STS
e RUN M
O
DE if all te
s
Test Set
u
Test Pas
Test Fai
s
t options a
r
u
p and Acti
o
sed
led
re selected
o
n
SECULIFE
D
:
67
D
F
BASE
68
SECULIF
DEFIBR
I
E DF
BASE
I
LLATOR
M
M
AXIMUM
E
E
NERGY
T
T
ESTS:
T
e
C
C
e
st Setup a
harge Tim
e
C
harge Tim
e
Result
s
GMC
-
a
nd Action
e
r Warning
e
r Running
s
-
I Messtech
n
n
ik GmbH
GMC
-
DEFI
DEFI
NOT
E
requi
r
-
I Messtech
n
BRILLAT
O
BRILLAT
O
E
: Some te
s
r
e the user
n
ik GmbH
O
R CARDI
O
O
R ECG PE
s
ts, like Pe
r
to manuall
y
O
VERSION
RFORMA
N
r
formance
W
y
progress
t
TESTS:
N
CE TEST:
W
aveforms
,
t
hrough the
,
do not ha
v
test.
Test Se
t
Test Pas
s
Wavefor
m
v
e quantitat
t
up and Act
i
s
ed
m
i
ve analys
e
SECULI
ion
e
s and ther
e
6
9
FE DF
BASE
e
fore
9
70 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
This page intentionally left blank.
GMC-I M
e
A
uto Seq
u
Sequenc
e
The Spla
s
user pres
s
e
sstechnik
G
u
ences are
p
e
configurati
o
s
h Screen id
e
s
es a key or
G
mbH
PRO
G
p
rogrammed
o
n software.
e
ntifies the
v
clicks the s
c
G
RAM
M
with an eas
y
SP
L
v
ersion of th
e
c
reen with th
M
ING AU
y to use PC
L
ASH S
e
program.
T
e mouse.
TO SE
Q
interface. T
h
CREEN
T
his screen
w
Q
UENC
E
h
is section s
h
w
ill be displa
y
E
S
h
ows how to
y
ed for 5 se
c
SECULIFE
D
use the Aut
o
c
onds, or un
t
Program
Version
71
D
F
BASE
o
t
il the
72
SEC
U
The f
o
scree
n
P
Se
q
Sel
e
Use
sele
seq
u
vie
w
U
LIFE DF
BAS
o
llowing is a
n
is describ
e
P
rogram M
e
uence
e
ction
this list to
c
t which
u
ence to
w
/edit.
Status
Message
E
general ove
r
e
d in full det
a
e
nu Ba
r
Com
bein
g
r
view of the
a
il later in thi
s
Port
g
used
Fi
T
h
c
o
re
a
S
E
OV
E
P
C Interfac
e
s
section.
l
e Control
h
is section is
o
nfiguration f
a
d/write the
E
CULIFE D
F
Sequenc
e
Use this
s
confi
g
ure
Sequenc
e
E
RVIEW
e
used for Pr
o
utilized to l
o
f
iles on the
P
auto confi
gu
F
BASE
e
Confi
g
ur
a
s
ection to
each Auto
e
test.
o
gramming
A
o
ad/save
P
C as well a
s
u
ration in the
a
tion
G
M
A
uto Seque
n
E
U
c
E
s
Task
Progres
s
Indicato
MC-I Messt
e
n
ces. Each
p
E
CG Seque
n
U
se this sect
c
onfigure ea
c
E
CG Auto S
e
s
T
o
or
e
chnik Gmb
H
p
art of this
n
ce Progra
m
ion to easil
y
c
h step of th
e
e
quence
Curr
e
o
day’s Date
H
m
ming
e
e
nt Time
GMC-I Messtechnik GmbH 73
SECULIFE DF
BASE
PROGRAM MENU
The program menu contains shortcuts to file operations as well as
program version information.
From the File Menu, you can Save or Load Auto Sequences as well as
Clear the History of files that were used. You can also Exit the program
from this menu.
The Help Menu provides access to program version information, shown below:
74 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
FILE CONTROL
The file control section allows the user to Load and Save Auto Sequence files, greatly expanding the number of
pre-programmed sequences from 50 to virtually unlimited. The user also uses the File Control section to Load
and Store Auto Sequences on the SECULIFE DF
BASE
.
Dropdown List – This list shows the history of files that have recently been used. This provides quick access for
switching between common Auto Sequence files.
Open Auto Sequence File – This button brings up the standard Windows Open File dialog box. It is used to load
an existing configuration file.
Save Auto Sequence to File – This button brings up the standard Windows Save File dialog box. It is used to
save the current configuration to a file for future reference.
Read Auto Sequence from SECULIFE DF
BASE
This button is used to load the configuration currently stored in
the SECULIFE DF
BASE
.
Download Auto Sequence to SECULIFE DF
BASE
– This button is used to send the configured Auto Sequence to
the SECULIFE DF
BASE
, where it is stored in non-volatile flash memory.
GMC-I Messtechnik GmbH 75
SECULIFE DF
BASE
SEQUENCE SELECTION
This section shows a list of all of the names of the Auto Sequences. It is
used to select an individual sequence for configuration. Once selected,
the configuration window will change to display the settings for the
selected sequence.
76 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
SEQUENCE CONFIGURATION
The sequence configuration window displays all of the configuration settings for each Auto Sequence. This
sample screen shows a defib test configuration.
Sequence Name – This name can be any string of up to 20
standard ASCII characters. NOTE: Not all ASCII characters are
valid and will be ignored.
Copy Sequence Button – This button opens the Copy
Sequence Screen that allows the user to quickly configure
similar test sequences.
Test Mode Selections – These selections allow each test to be
configured as a Defibrillator Only, a Pacer Only or a Defib &
Pacer test.
Configure Test Buttons – These buttons are used to alternate
between defib and pacer test configuration windows.
Defibrillator Test Details – Each of the potential tests and test
details for the Defibrillator are displayed for configuration. For
ease of programming, individual steps can be deleted or added
and individual tests can be included or not included.
Insert and Delete Steps Buttons – These buttons will open the
Insert Steps Screen or the Delete Steps Screen.
GMC-I Messtechnik GmbH 77
SECULIFE DF
BASE
Copy Sequence Screen
This function allows the user to quickly configure similar Auto Sequences. Simply select the source and target
test sequences, press OK, and the target sequence will be overwritten with the configuration from the source
sequence configuration. The Cancel button will exit the window without modifying any configuration settings.
78 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
Insert Step and Deleting Step Screens
The insert and delete functions allow the user to quickly modify an existing test configuration. Deleting a step will
move all of the tests following the deleted test up by one step and clear the final step. Inserting a step will shift all
following steps down by one step and clear the selected step location.
Defibrillator Examples:
Pressing OK here would shift steps 4-19
down by one step and insert a blank step
at step 4.
Pressing OK here would shift steps 6- 20
up by one step and insert a blank step at
step 20.
GMC-I Messtechnik GmbH 79
SECULIFE DF
BASE
ECG CONFIGURATION SECTION
This section configures the ECG Performance sequence when the ECG
Performance Test option is set to YES for a Defibrillator Test.
The ECG sequence consists of up to 10 steps. Each step consists of a
selected waveform group (Disabled, NSR, AED, Arrhythmia or
Performance), output waveform and output amplitude.
There is only one ECG sequence for all 50 Auto Sequence tests.
To use less than 10 steps, set the ECG output group of the next step
after the last to “Disabled.”
80 GMC-I Messtechnik GmbH
SECULIFE DF
BASE
This page intentionally left blank.
GMC-I M
e
WAR
R
DEFE
C
INTEN
D
EXCL
U
INCLU
D
FOR A
GMC-I
NO P
E
A
SSU
M
REME
D
REPL
A
GMC-I
e
sstechnik
G
R
ANTY
: G
M
C
TS IN MA
T
D
ED. THIS
W
U
SIONS: TH
D
ING, BUT
PARTICUL
A
MESSTEC
H
E
RSON OT
H
M
E ANY LIA
B
D
IES: THE
A
CEMENT O
MESSTEC
H
G
mbH
M
C-I MESS
T
T
ERIALS A
W
ARRANTY
IS WARRA
N
NOT LIMIT
E
A
R PURPO
S
H
NIK GMBH
H
ER THAN
B
ILITY.
PURCHAS
E
F DEFECTI
V
H
NIK GMBH
,
LIM
I
T
ECHNIK
G
N
D WORK
M
IS EFFECT
N
TY IS IN L
E
D TO AN
Y
S
E.
IS NOT LIA
B
AN OFFIC
E
E
R'S SOLE
A
V
E PARTS
O
,
THE REFU
I
TED W
A
G
MBH
WAR
R
M
ANSHIP
U
IVE FOR T
W
L
IEU OF
A
N
Y
Y
IMPLIED
W
B
LE FOR A
N
E
R IS AUT
H
A
ND EXCL
U
O
R PRODU
ND OF THE
A
RRAN
T
R
ANTS ITS
U
NDER TH
E
W
ELVE MO
N
Y
OTHER
W
W
ARRANTY
N
Y INCIDE
N
H
ORIZED T
O
U
SIVE RE
M
CTS, WITH
O
PURCHAS
E
T
Y
NEW PRO
D
E
SERVICE
N
THS FROM
W
ARRANTY
OF MERC
H
TAL OR C
O
O
GIVE AN
EDY SHAL
L
O
UT CHAR
G
E
PRICE.
D
UCTS TO
B
E
FOR WH
I
M
THE DATE
EXPRESS
E
H
ANTABILI
T
O
NSEQUEN
T
Y OTHER
W
L
BE: (1) T
G
E. (2) AT
T
SECULIFE
D
B
E FREE F
R
CH THEY
OF SHIPM
E
E
D OR IMP
L
T
Y OR FIT
N
T
IAL DAMA
G
W
ARRANT
Y
HE REPAI
R
T
HE OPTIO
N
81
D
F
BASE
R
OM
ARE
E
NT.
L
IED,
N
ESS
G
ES.
Y
OR
R
OR
N
OF
82
SEC
U
U
LIFE DF
BAS
M
L
D
M
W
A
V
P
D
R
A
V
M
M
A
T
P
T
V
M
M
A
T
P
T
E
M
ETHOD
L
OAD RES
D
ISPLAY
R
M
EASURE
M
W
INDOW
A
BSOLUT
E
V
OLTAGE
P
ULSE WI
D
D
ELAY
R
ESOLUTI
O
A
CCURAC
Y
V
OLTAGE
M
AX CUR
R
M
AX ENE
R
A
CCURAC
Y
T
RIGGER
L
P
LAYBAC
K
T
EST PUL
S
V
OLTAGE
M
AX CUR
R
M
AX ENE
R
A
CCURAC
Y
T
RIGGER
L
P
LAYBAC
K
T
EST PUL
S
ENE
R
ISTANCE
R
ESOLUTI
O
M
ENT TIM
E
E
MAX PE
A
D
TH
O
N
Y
ENE
R
R
ENT
R
GY
Y
L
EVEL
K
AMPLITU
D
S
E
ENE
R
R
ENT
R
GY
Y
L
EVEL
K
AMPLITU
D
S
E
SPECI
F
R
GY OUTP
U
GE
N
O
N
E
A
K
CARDI
O
R
GY OUT
P
HIG
H
D
E
R
GY OUT
P
LO
W
D
E
F
ICATIO
N
U
T MEAS
U
NERAL
Mono
p
5
0
non-
i
O
VERSIO
N
0
P
UT MEAS
U
H
RANGE
+/-2% of r
e
+/-2 Jo
u
1 m
v
12
5
P
UT MEAS
U
W
RANGE
+/-2% of
r
+/- 0.4 J
1 m
V
5
J
N
S
U
REMENT
p
hasic or B
0
ohm +/- 1
i
nductive (
<
0.1 Joules
100 ms
6000 Volts
100 ms
N
0
to 6000
m
0.1 ms
+/-2 ms
U
REMENT
<5000 Volt
s
100 Amps
1000 Joule
s
e
ading for
>
u
les for <10
100 Volts
v
/ 1000 V L
5
Joules +/-
U
REMENT
<1000 Volt
s
20 Amps
50 Joules
r
eading for
>
oules for <
2
20 Volts
V
/ 1000 V
L
J
oules +/-2
0
G
M
i
phasic
%
,
<
1 µH)
m
s
s
s
>
100 Joule
s
0 Joules
e
ad 1
20%
s
>
20 Joules
2
0 Joules
ead 1
0
%
MC-I Messt
e
s
e
chnik Gmb
H
H
GMC-I Messtechnik GmbH 83
SECULIFE DF
BASE
ENERGY OUTPUT MEASUREMENT
OTHER
OSCILLOSCOPE OUTPUT
HIGH MEASURE RANGE
1000:1 amplitude-attenuated
LOW MEASURE RANGE
200:1 amplitude-attenuated
WAVEFORM PLAYBACK
OUTPUT
LEAD I & PLATES
SCREEN
200:1 Time Base Expansion
SYNC TIME MEASUREMENTS
TIMING WINDOW
Starts at peak of
each R-wave
TEST WAVEFORMS
All waveform simulations available
DELAY TIME ACCURACY
+/- 1 ms
CHARGE TIME MEASUREMENT
From 0.1 to 99.9 sec
ECG NSR
RATE
30,40,45,60,80,90,100,120,140,160,
180,200,220,240,260,280,300 BPM
ACCURACY
+/- 1%
AMPLITUDE
0.5,1.0,1.5,2.0 mV (Lead II)
ACCURACY
+/- 2% @ Lead II
HIGH LEVEL
200 times Amplitude
ACCURACY
+/- 5%
QRS DURATION
80ms
ECG PERFORMANCE
SINE WAVE
0.1,0.2,0.5,5,10,40,50,60,100 Hz
SQUARE WAVE
0.125, 2.000 Hz
TRIANGLE WAVE
2.000, 2.500 Hz
PULSE WAVE
30,60,120 BPM; 60 ms width
AMPLITUDE
0.5,1.0,1.5,2.0 mV (Lead II)
RATE ACCURACY
+/- 1%
AMPLITUDE ACCURACY
+/- 2% @ Lead II
ECG GENERAL
LEAD TO LEAD
IMPEDANCE
(RL, LL, RA, LA)
1000 ohm
LEAD TO LEAD
IMPEDANCE
(V1-V6)
1000 ohm
84
SECULIF
E DF
BASE
M
u
M
u
P
o
P
o
ECG A
R
V
Se
c
Rig
h
Pre
m
V
e
SHOCK A
D
Coar
s
Fin
e
u
ltifocal Ve
n
u
ltifocal Ve
n
o
lyfocal Ve
n
o
lyfocal Ve
n
SupraVe
n
R
RHYTHMI
A
V
entricular
F
Atrial Fib
r
c
ond Degre
h
t Bundle
B
m
ature Atri
a
PVC
E
PVC St
a
PVC R
Multifoc
a
Bige
m
Run of 5
e
ntricular T
a
D
VISORY
A
ECG SI
G
A
syst
o
s
e Ventricu
e
Ventricul
a
n
tricular Ta
c
n
tricular Ta
n
tricular Ta
c
n
tricular Ta
c
n
tricular Ta
c
A
SELECT
F
ibrillation
r
illation
e
A
-V Bloc
k
B
ranch Blo
c
a
l Contracti
o
E
arly
a
ndard
on T
a
l PVC
m
iny
PVCs
a
chycardia
A
LGORITH
G
NALS
o
le
lar Fibrillati
a
r Fibrillatio
n
c
hycardia
@
chycardia
@
c
hycardia
@
c
hycardia
@
c
hycardia
@
IONS
k
k
o
n
M TEST
o
n
n
@
140 BPM
@
160 BP
M
@
140 BPM
@
160 BPM
@
90 BPM
GMC
-
M
M
M
-
I Messtech
n
n
ik GmbH
GMC-I Messtechnik GmbH 85
SECULIFE DF
BASE
DATA INPUT/OUTPUTS
Parallel Printer Port
RS-232C (for computer control)
PHYSICAL
DISPLAY
LCD Graphical 240 X 64 Pixels,
Backlit
3.4 x 9.8 x 10.7 Inches
ENCLOSURE
(86.4 x 249 x 271.8 mm)
Royalite R59
UL Flame Rating 94 V-0
WEIGHT
< 5 Lbs
(< 2.3 Kg)
FACE PLATE
Lexan, Back printed
OPERATING RANGE
15 to 40 C
STORAGE RANGE
-20 to 65 C
ELECTRICAL
POWER
Battery, 9 VDC (2 required)
Alkaline
20 - 21103 (120 VAC) (US Version)
BATTERY ELIMINATOR
20 - 21101 (220 VAC) (Euro Version)
10V, 300 mA DC
86
S
E
P
r
If
S
e
Edit
e
G
M
d
90
4
E
CULIFE DF
B
r
oduct Su
p
required pl
e
GMC-I
M
Produc
t
Phone
+
Fax
+
E-Mail
s
e
rvice Cen
t
Repair
Servic
e
and Re
If requi
r
GM
Se
r
Th
o
90
4
Ph
o
Fa
x
E-
M
ww
w
This ad
d
Please
* DAkkS
for El
e
per DI
A
ccre
d
- alter
n
power
,
e
d in Germany • Subj
e
M
C-I Messtec
h
d
westpark 15
4
49 Nürnberg
B
ASE
p
port
e
ase conta
c
M
esstechn
i
t
Support H
+
49 911 86
+
49 911 86
0
s
upport@g
o
t
e
r
and Repla
e
Calibrati
o
ntal Instru
r
ed please
c
C-I Servic
e
r
vice Cent
e
o
mas-Mann
4
71 Nürnbe
r
o
ne
+49
x
+49
M
ail
ser
v
w
.gmci-ser
v
dress is on
l
contact ou
r
Calibratio
n
e
ctrical Qua
n
N EN ISO/I
E
d
ited meas
u
n
ating volta
g
,
DC power
e
ct to change withou
t
h
nik GmbH
Germany
c
t:
i
k GmbH
otline
02-0
0
2-709
o
ssenmetr
a
cement P
a
o
n Center
*
ment Serv
i
c
ontact:
e
GmbH
er
-Strasse 2
0
r
g • Germa
n
911 81771
911 81771
v
ice@goss
e
v
ice.com
l
y valid in
G
r
represent
a
n
Laborator
y
n
tities D–K–
1
E
C 17025:2
u
red quanti
t
g
e, -altern
a
, -capacita
n
t
notice •A PDF versi
o
a
watt.com
a
rts
*
i
ce
0
n
y
8-0
8-253
e
nmetrawatt
G
ermany.
a
tives or su
b
y
1
5080-01-01
a
005
t
ies: direct
v
a
ting curren
t
n
ce, -frequ
e
o
n is available on the
Phone +49
Fax +49
9
E-Mail info
@
www.gossen
m
t
.com
b
sidiaries f
o
a
ccredited
v
oltage, dir
e
t
-values,
A
e
ncy and te
m
Internet
911 8602-11
1
9
11 8602-77
7
@
gossenmetr
a
m
etrawatt.co
m
o
r service i
n
e
ct current
-
A
C active p
o
m
perature
1
7
a
watt.com
m
n
other cou
n
-
values, D
C
o
wer, AC a
p
GMC-I Me
s
n
tries.
C
-resistanc
p
parent
s
stechnik G
m
e
,
m
bH
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECULIFE DF BASE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECULIFE DF BASE in the language / languages: English as an attachment in your email.

The manual is 3,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info