590776
80
Zoom out
Zoom in
Previous page
1/92
Next page
80 GMC-I Messtechnik GmbH
19 Technische karakteristieken
Fun-
ctie
Meetgrootheid Weergavebereik
Reso-
lutie
Ingangsim-
pedantie/
meetstroom
Meetbereik
Nom.
waarden
Meetonnauw-
keurigheid
Intrinsieke
onveiligheid
Aansluitingen
Stekker-
inzet-
stuk
1)
2-polige
Adapter
3-polige
Adapter
Sonde
Tangen
WZ12C Z3512A
MFLEX
P300
U
U
L-PE
U
N-PE
0 ... 99,9 V 0,1 V
5 MΩ
0,3 ... 600 V
1)
U
N
=
120 V
230 V
400 V
f
N
= 16
2
/
3
/50/
60 Hz
±(2% v.d.m.+5D)
±
(1% v.d.m.+5D)
●●
100 ... 600 V 1 V ±(2% v.d.m.+1D)
±
(1% v.d.m.+1D)
f
15,0 ... 99,9 Hz
100 ... 999 Hz
0,1 Hz
1 Hz
DC 15,4 ... 420 Hz
±
(0,2%
v.d.m.+1D)
±
(0,1%
v.d.m.+1D)
U
3~
0 ... 99,9 V
100 ... 600 V
0,1 V
1 V
0,3 ... 600 V
±(3% v.d.m.+5D)
±(3% v.d.m.+1D)
±
(2% v.d.m.+5D)
±
(2% v.d.m.+1D)
U
SONDE
0 ... 99,9 V
100 ... 600 V
0,1 V
1 V
1,0 ... 600 V
±(2% v.d.m.+5D)
±(2% v.d.m.+1D)
±
(1% v.d.m.+5D)
±
(1% v.d.m.+1D)
U
L-N
0 ... 99,9 V
100 ... 600 V
0,1 V
1 V
1,0 ... 600 V
1)
±(3% v.d.m.+5D)
±(3% v.d.m.+1D)
±
(2% v.d.m.+5D)
±
(2% v.d.m.+1D)
●●
I
ΔN
I
F
U
IΔN
0 ... 70,0 V 0,1 V 0,3 · I
ΔN
5 ... 70 V
U
N
=
120 V
230 V
400 V
f
N
= 50/60 Hz
U
L
= 25/50 V
I
ΔN
=
10 mA
30 mA
100 mA
300 mA
500 mA
2)
U
N
230 V
+10% v.d.m.+1D
+1% v.d.m.–1D ...
+9% v.d.m.+1D
●●
naar
keuze
R
E
10 Ω ... 999 Ω
1,00 kΩ ... 6,51 kΩ
1 Ω
0,01 kΩ
I
Δ
N
= 10 mA · 1,05
Rekenkundige
waarde
van
R
E
= U
IΔN
/
I
ΔN
3 Ω ... 999 Ω
1 kΩ ... 2,17 kΩ
1 Ω
0,01 kΩ
I
Δ
N
= 30 mA · 1,05
1Ω ... 651 Ω 1Ω
I
Δ
N
=100 mA · 1,05
0,3 Ω ... 99,9 Ω
100 Ω ... 217 Ω
0,1 Ω
1 Ω
I
Δ
N
=300 mA · 1,05
0,2 Ω ... 9,9 Ω
10 Ω ... 130 Ω
0,1 Ω
1 Ω
I
Δ
N
=500 mA · 1,05
I
F
(I
ΔN
= 10 mA) 3,0 ... 13,0 mA
0,1 mA
3,0 ... 13,0 mA 3,0 ... 13,0 mA
±(5% v.d.m.+1D)
±(3,5%
v.d.m.+2D)
I
F
(I
ΔN
= 30 mA) 9,0 ... 39,0 mA 9,0 ... 39,0 mA 9,0 ... 39,0 mA
I
F
(I
ΔN
= 100 mA) 30 ... 130 mA 1 mA 30 ... 130 mA 30 ... 130 mA
I
F
(I
ΔN
= 300 mA) 90 ... 390 mA 1 mA 90 ... 390 mA 90 ... 390 mA
I
F
(I
ΔN
= 500 mA) 150 ... 650 mA 1 mA 150 ... 650 mA 150 ... 650 mA
U
IΔ
/ U
L
= 25 V 0 ... 25,0 V
0,1 V als I
Δ
0 ... 25,0 V
+10% v.d.m.+1D
+1% v.d.m.–1D ...
+9% v.d.m.+1D
U
IΔ
/ U
L
= 50 V 0 ... 50,0 V 0 ... 50,0 V
t
A
(I
ΔN
· 1)
0 ... 1000 ms
0 ... 500 ms
1 ms
I
Δ
N
· 1,05 < 0,55 A
I
Δ
N
· 1,05 > 0,55 A
0 ... 1000 ms
0 ... 500 ms
U
N
230 V
±4 ms ±3 ms
t
A
(I
ΔN
· 2) 0 ... 200 ms 1 ms
I
ΔN
· 2 0,6 A
I
ΔN
· 2 1A
0 ... 200 ms
t
A
(I
ΔN
· 5) 0 ... 40 ms 1 ms I
ΔN
· 5 1,5 A 0 ... 40 ms
Z
L-PE
Z
L-N
Z
L-PE
()
Z
L-N
0 ... 999 mΩ
1,00 ... 9,99 Ω
1 mΩ
0,01 Ω
0,1 Ω
3,7... 7 A~
0,10 ... 0,49 Ω
0,50 ... 0,99 Ω
1,00 ... 9,99 Ω
U
N
= 120/230 V
U
N
= 400 V
1)
/
500 V bij Z
L-PE
f
N
= 16
2
/
3
/50/
60 Hz
±
(10% v.d.m.+20D)
±
(10% v.d.m.+20D)
±
(5% v.d.m.+3D)
±
(5% v.d.m.+20D)
±
(4% v.d.m.+20D)
±
(3% v.d.m.+3D)
Z
L-PE
Z
L-PE
+ DC
0 ... 999 mΩ
1,00 ... 9,99 Ω
10,0 ... 29,9 Ω
3,7 ... 7 A AC
0,5/1,25 A DC
0,25 ... 0,99 Ω
1,00 ... 9,99 Ω
U
N
= 120/230 V
f
N
= 16
2
/
3
/50/
60 Hz
±
(18% v.d.m.+30D)
±
(10% v.d.m.+3D)
±
(6% v.d.m.+50D)
±
(4% v.d.m.+3D)
I
K
(Z
L-PE
(),
Z
L-PE
+ DC)
0 ... 999 A
1,00 ... 9,99 kA
10,0 ... 50,0 kA
1 A
10 A
100 A
120 (108 ... 132) V
230 (196 ... 253) V
400 (340 ... 440) V
500 (450 ... 550) V
Rekenkundige waarde van Z
L-P E
Z
L-PE
(15 mA)
0,5 ... 99,9 Ω
100 ... 999 Ω
0,1 Ω
1 Ω
15 mA
10 ... 100 Ω
100 ... 1000 Ω
±
(10%
v.d.m.+10D)
±
(8% v.d.m.+2D)
±
(2% v.d.m.+2D)
±
(1% v.d.m.+1D)
I
K
(15 mA)
0,10 ... 9,99 A
10,0 ... 99,9 A
100 ... 999 A
14)
0,01 A
0,1 A
1 A
100 mA ... 12 A
(U
N
= 120 V)
200 mA ... 25 A
(U
N
= 230 V)
Rekenkundige waarde van
I
K
= U
N
/Z
L-PE
(15 mA)
R
E
R
E.sl
(zonder sonde)
R
E
(met sonde)
0 ... 999 mΩ
1,00 ... 9,99 Ω
10,0 ... 99,9 Ω
100 ... 999 Ω
1 kΩ ... 9,99 kΩ
1 mΩ
0,01 Ω
0,1 Ω
1 Ω
0,01 kΩ
3,7 ... 7 A~
3,7 ... 7 A~
400 mA
40 mA
4 mA
0,10 Ω ... 0,49 Ω
0,50 Ω ... 0,99 Ω
1,0 Ω ...9,99 Ω
10 Ω ...99,9 Ω
100 Ω ...999 Ω
1 kΩ ...9,99 kΩ
U
N
zoals functie U
1)
f
N
= 50/60 Hz
±
(10% v.d.m.+20D)
±
(10% v.d.m.+20D)
±
(5% v.d.m.+3D)
±
(10% v.d.m.+3D)
±
(10% v.d.m.+3D)
±
(10% v.d.m.+3D)
±
(5% v.d.m.+20D)
±
(4% v.d.m.+20D)
±
(3% v.d.m.+3D)
±
(3% v.d.m.+3D)
±
(3% v.d.m.+3D)
±
(3% v.d.m.+3D)
●●
R
E (15 mA)
(zonder/met
sonde)
0,5 ... 99,9 Ω
100 ... 999 Ω
0,1 Ω
1 Ω
15 mA
10 Ω ...99,9 Ω
100 Ω ...999 Ω
U
N
= 120/230 V
f
N
= 50/60 Hz
±
(10% v.d.m.+10D)
±
(8% v.d.m.+2D)
±
(2% v.d.m.+2D)
±
(1% v.d.m.+1D)
R
E.sl
(zonder sonde)
+ DC
R
E.sl
(met sonde)
+ DC
0 ... 999 mΩ
1,00 ... 9,99 Ω
10,0 ... 29,9 Ω
1 mΩ
0,01 Ω
0,1 Ω
3,7 ... 7 A AC
0,5/1,25 A DC
0,25 ... 0,99 Ω
1,00 ... 9,99 Ω
U
N
= 120/230 V
f
N
= 50/60 Hz
±
(18%
v.d.m.+30D)
±(10%
v.d.m.+3D)
±(6%
v.d.m.+50D)
±(4%
v.d.m.+3D)
U
E
0 ... 253 V 1 V 3,7 ... 7 A~
R
E
= 0,10 ... 9,99
Ω
U
N
= 120/230 V
f
N
= 50/60 Hz
Rekenkundige waarde U
E
= U
N
· R
E
/
R
E.sl
R
E
Sel
Tang
R
E.sel
(alleen met sonde)
0 ... 999 mΩ
1,00 ... 9,99 Ω
10,0 ... 99,9 Ω
100 ... 999 Ω
1 mΩ
0,01 Ω
0,1 Ω
1 Ω
3,7 ... 7 A~
3,7 ... 7 A~
400 mA~
40 mA~
0,25 ... 300 Ω
4)
U
N
zoals functie U
f
N
= 50/60 Hz
±
(20% v.d.m.+20D)
±
(15% v.d.m.+20D)
R
E.sel
+ DC
(alleen met sonde)
0 ... 999 mΩ
1,00 ... 9,99 Ω
10,0 ... 99,9 Ω
100 ... 999 Ω
1 mΩ
0,01 Ω
0,1 Ω
1 Ω
3,7 ... 7 A AC
0,5/1,25 A DC
0,25 ... 300 Ω
R
E.tot
< 10 Ω
4)
U
N
= 120/230 V
f
N
= 50/60 Hz
±
(22% v.d.m.+20D)
±
(15% v.d.m.+20D)
EXTRA
Z
ST
0 ... 30 MΩ 1 kΩ 2,3 mA bij 230 V
10 kΩ ... 199 kΩ
200 kΩ ... 30 MΩ
U
0
= U
L-N
±
(20% v.d.m.+2D)
±
(10% v.d.m.+2D)
±
(10% v.d.m.+3D)
±
(5% v.d.m.+3D)
●●●
IMD-test
20 ... 648 kΩ
2,51 MΩ
1 kΩ
0,01 MΩ
IT-netspanning
U.it = 90 ... 550 V
20 kΩ ... 199 kΩ
200 kΩ ... 648 kΩ
2,51 MΩ
IT-net - nom.
spanningen
UN.it =
120/230/400/
500 V
f
N
= 50/60 Hz
±7%
±12%
±3%
±5%
±10%
±2%
●●
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MPRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MPRO in the language / languages: Dutch as an attachment in your email.

The manual is 2,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt PROFITEST MPRO

Gossen Metrawatt PROFITEST MPRO User Manual - English - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info