4 GMC-I Messtechnik GmbH
User Interface (Example METRISO TECH)
LCD panel
Start measurement
Parameters transfer
Exit
Activate instrument
Continuous
Scroll down:
Red LED: limit value exceeded
Red LED:
– External voltage with device switched off *
Setup menu SEt
Function
selector switch
Guide for
carrying strap
Guide for
carrying strap
M Vk
TRMS
AC
DC
Rlo>10%
MAN
DATA
STORE
ZERO G
ISO
2500V
1000 V
Tk
1
0
0
k
1
G
1
0
k
1
M
1
0
G
0
1
0
0
0
V
12
0
0
G
1
0
0
M
1
0
M
Green LED: limit value adhered to
SETUP: parameter selection
V: voltage type selection
Rlo: polarity reversal
Scroll up:
SETUP: parameter selection
V: voltage type selection
Rlo: polarity reversal
– Test/Measuring voltage with device switched on
for Riso/Rins,
menu
from standby
state
measurement
R & R
LO
– Discharge voltage for Riso/Rins
* not
METRISO INTRO
8 GMC-I Messtechnik GmbH
2 Safety Features and Precautions
The electronic measuring and test instrument is manufactured
and tested in accordance with safety regulations IEC/EN 61010-1
/ VDE 0411-1 and EN 61557. When used for its intended pur-
pose, safety of the operator, as well as that of the instrument, is
assured.
Read the operating instructions thoroughly and carefully before
using your instrument. Follow all instructions contained therein.
The measuring and test instrument may not be placed into ser-
vice:
If the battery compartment lid has been removed
If external damage is apparent
If connector cable or measuring adapters are damaged
If the instrument no longer functions flawlessly
After extraordinary damage due to transport
After long periods of storage under unfavorable conditions
(e.g. humidity, dust or extreme temperature)
Opening of Equipment / Repair
The equipment may be opened only by authorized service per-
sonnel to ensure the safe and correct operation of the equipment
and to keep the warranty valid.
Even original spare parts may be installed only by authorized ser-
vice personnel.
In case the equipment was opened by unauthorized personnel,
no warranty regarding personal safety, measurement accuracy,
conformity with applicable safety measures or any consequential
damage is granted by the manufacturer.
Meaning of Symbols on the Instrument
Warning concerning a source of danger
(attention: observe documentation!)
Protection class II device
CAT II/ III Device assigned to measuring categories
METRISO INTRO/TECH:
CAT II 1000 V / CAT III 600 V / CAT IV 300 V
METRISO BASE:
CAT III 600 V / CAT IV 300 V
EC mark of conformity
The device and included batteries may not be dis-
posed of with the trash. Further information regarding
the WEEE mark can be accessed on the Internet at
www.gossenmetrawatt.com by entering the search
term “WEEE”.
Calibration Seal (blue seal):
See also “Recalibration” on page 30.
!
GMC-I Messtechnik GmbH 9
3 Initial Start-Up
3.1 Battery test
Four different battery symbols, ranging from fully depleted to fully
charged, continuously indicate the momentary charge level in the
upper left-hand corner of the display
If battery voltage has fallen below the allowable lower
limit, the pictograph shown at the right appears. The
instrument does not function if the batteries have been depleted
excessively, and no display appears.
3.2 Installing or Replacing Batteries
New batteries must be inserted for initial start-up, or if only one
filled segment remains in the battery symbol.
Attention!
!
Before opening the battery compartment (see page 5 for
location), disconnect the instrument from the measuring
circuit (mains) at all poles.
Eight 1.5 V size AA batteries in accordance with IEC LR 6 are
required for operation of the insulation measuring instrument. Use
new alkaline manganese batteries only.
Rechargeable NiCd or NiMH batteries may also be used. These
can only be recharged externally. We recommend rechargeable
NiMH batteries.
Always replace batteries in complete sets.
Dispose of batteries in an environmentally sound fashion.
Ð Loosen both slotted screws for the battery compartment lid
on the back, and remove the lid.
Ð Remove the battery holder and insert eight 1.5 V size AA bat-
teries with correct polarity in accordance with the symbols.
Attention!
!
Make sure that all of the batteries are inserted with correct
polarity. If just one battery is inserted with reversed polar-
ity, it will not be recognized by the instrument and may
result in leakage from the batteries.
Ð Push the battery holder into the battery compartment such
that the battery holder’s contacts touch the contact springs at
the bottom of the battery compartment (see drawing on
page 3).
If the battery holder is not inserted as specified, the instrument
cannot be supplied with power.
Ð Replace the battery compartment lid and retighten the
screws.
Attention!
!
The instrument may only be placed into service if the
battery compartment lid is securely fastened!
GMC-I Messtechnik GmbH 19
7 Measuring Resistance – kΩ/Ω Function
(METRISO BASE/TECH)
Ð Connect the device under test to the + and COM jacks.
Resistance can only be measured at voltage-free objects. If mains
voltage or external voltage is applied to the measurement inputs,
measurement cannot be started.
This is indicated by the high-voltage symbol which appears at the
display.
Ð Select measuring function kΩ or Ω with the rotary switch.
Ð Start an individual measurement by briefly pressing the START
key, or initiate continuous measurement by briefly pressing
the CONTIN key.
DATA blinks at the display until the measured value has settled in.
kΩ
+
C
O
M
Rx
Rx
0V !
!
DATA
20.4
0
1
0
0
0
START
ENTER
GMC-I Messtechnik GmbH 33
Caution:
Open the overcurrent protective device
Disconnect the N conductor
Jumper the L and N conductors
Insulation measurement between L conductors and N to PE
Device switch can be open – if single-pole
In the distributor: individual and combined measurements
34 GMC-I Messtechnik GmbH
14.2 Attaching the strap to the test instrument
14.3 Attaching the Test Probe Holder to the Carrying Strap
Front
Feed the strap through from the front
of the test instrument and secure it
with the slotted screw (M3).
Back
1
Bottom Right
Detach the strap from the instrument:
Turn out the slotted screw (M3) at the
bottom.
Bottom Left
Strap
Clasp
Clasp
Front View
2
Slide the strap through the test probe
holder.
Eyelet for Attachment to Tester (METRISO ...)
Side View
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO TECH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO TECH in the language / languages: English as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRISO TECH

Gossen Metrawatt METRISO TECH User Manual - German - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info