590650
15
Zoom out
Zoom in
Previous page
1/28
Next page
GMC-I Messtechnik GmbH 15
6 Database Functions
The displayed measurement data for each measurement can be saved to
an internal database, with or without a comment. A data record must be
created and allocated to a specific memory address in order to be able to
assign the individual measurement values to different buildings, distribu-
tion cabinets and measuring circuits.
6.1 Creating a Data Record – Data Function
Ð Press the Data key.
Ð First create the desired memory address with the help of the softkeys.
After acknowledging with the START key (press at center), the cursor
appears at the first data entry position (BUILDING).
Ð With the help of the softkeys, entries can be made to the BUILDING,
DISTRIBUTOR CABINET, RCD No. and CIRCUIT fields one after the other, and
a designation can be entered for the electrical circuit.
Entering Data:
Display the desired alphanumeric character by pressing the or
the key, and then select the character with the corresponding
softkey.
Control characters can be entered in the same way and have the fol-
lowing meanings:
 Move cursor to the left (without deleting data)
 Move cursor to the right (without deleting data)
 Same function as the START key
After each character is selected, the cursor moves one position to the
right. If or the START key is activated (press at center), the cursor
moves to the next entry field. After the fields BUILDING, DISTRIBUTOR
CABINET, RCD No. and CIRCUIT have been completed, and after acknowl-
edgement has been confirmed with the softkey, the data fields are
displayed as inverse images. After the softkey has been activated
once again, a designation for the selected electrical circuit can be en-
tered.
Note
+
These entries are required by the PC software in order to enter
measurement values into the database, and to generate reports
with this information automatically.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO C in the language / languages: English as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRISO C

Gossen Metrawatt METRISO C User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info