5. Technical data METRALINE EXM25
5.1 Identication marking / Ex zones
EC-Type Examination Certicate
BVS 13 ATEX E 089
II 2G Ex ib IIC T4/T6 Gb
I M2 Ex ib I Mb
5.2 Safety-related limit values
Intrinsically electric circuits
Voltage (by U
pp
= 50 V tip) 2 A
Internal inductance Li < 5 μH
Voltage with measurement tips:
Type EXM 72010
Class IIC AC/DC ≤ 690 V with tip EXM 72010
Class IIB AC/DC ≤ 690 V with tip EXM 72010
Class I AC/DC ≤ 1000 V with tip EXM 72010
Resistance ranges maximum values in case of fault:
Voltage 6 V
Current 2 mA
Maximum permissible external
capacitance/inductance:
Ex group IIC 40 µF/1000mH
Ex group IIB 1000 µF/1000mH
Ex group I 3000 µF/1000mH
Frequency 2 up to 10 kHz
Current (up to 50 V
U
ss
) 2 A
internal inductance Li < 5 μH
Energie source (moulded design):
NiMH accumulator
Type Typ Z209A/T4
Nominal voltage DC 8,4 V
Maximum voltage U
0
11,2 V
Temperature range T4
Lithium battery
Type EXM Z209B Li/T6
Nominal voltage DC 3,6 V
Maximum voltage U
0
3,9 V
Temperature range T6
Temperature with TMZ 25:
-80°C <TA< +600°C
Curent with clamp-on ammeter type MZ 1005:
(solely for class I)
AC/DC 1000 A
Frequency up to 500 Hz
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRALINE EXM25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRALINE EXM25 in the language / languages: English, German as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info