V/Hz, Ω, Temperature, and A/Hz Measurements
5 Measurements
5.1 Voltage Measurement
Notes Regarding Voltage Measurement
The multimeter may only be operated with installed batteries or
rechargeable batteries. Dangerous voltages are otherwise not
indicated, and the instrument may be damaged.
The multimeter may only be operated by persons who are
capable of recognizing contact hazards and taking the appropri-
ate safety precautions. Contact hazards exist anywhere, where
voltages of greater than 33 V RMS may occur.
The test probes may only be only gripped up to the finger
guard.
Do not touch the metallic test probes under any
circumstances.
Avoid working alone when taking measurements which involve
contact hazards. Be certain that a second person is present.
Maximum permissible voltage between the connector sockets,
(9 and 10) and ground (8) is 1000 V for measuring category III,
and 600 V for measuring category IV.
Be prepared for the occurrence of unexpected voltages at
devices under test (e.g. defective devices). For example,
capacitors may be dangerously charged.
No measurements may be made with this instrument in
electrical circuits with corona discharge (high-voltage).
Special care is required when measurements are made in HF
electrical circuits. Dangerous pulsating voltages may be
present.
Be aware of the fact that dangerous voltage spikes are not displayed
during measurement with the low-pass filter.
We recommend measuring voltage without the low-pass filter first, in
order to be able to detect any dangerous voltages.
Be absolutely certain that the measuring ranges are not
overloaded beyond their allowable capacities. Limit values are
included in chapter 8, “Technical Data”, in the table entitled
“Measuring Functions and Measuring Ranges” in the “Over-
load Capacity” column.
Scope of Functions, Voltage Measurement
1)
A 1 kHz low-pass filter can be used in this case, in order to filter out high
frequency pulses of greater than 1 kHz, for example when performing
measurements at pulsed motor drives.
2)
Input resistance of approx. 1 MΩ. Erroneous displays resulting from
capacitive coupling during voltage measurement in power supply
systems are reduced to a minimum in this way.
Function
METRA
HIT
X-TRA/
OUTDOOR
METRAHIT
TECH
METRAHIT
PRO
METRA
HIT
BASE
V AC / Hz TRMS
(Ri 9 MΩ)
••••
V AC / LP filter 1 kHz
1)
(Ri = 1 MΩ
2)
) TRMS
•••
V AC+DC TRMS
(Ri 9 MΩ)
••••
V DC (Ri 9 MΩ)
••••
MHz at 5 V AC
———
Duty cycle as %
———
Freq. response, V AC
20 kHz 10 kHz 10 kHz 1 kHz
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT X-TRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT X-TRA in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT X-TRA

Gossen Metrawatt METRAHIT X-TRA User Manual - Dutch - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info