590615
2
Zoom out
Zoom in
Previous page
1/71
Next page
2 GMC-I Messtechnik GmbH
Standard Equipment Contact Persons
Standard Equipment
1multimeter
1 KS17-2 measurement cable set
2 batteries
1 abbreviated operating instructions
1 CD ROM (contents: amongst other topics operating
instructions and data sheet)
1 DAkkS calibration certificate
1)
For 15,400 measured values, sampling rate adjustable from 0.1 second to 9 hours
Function
SECU
LIFE
HIT
METRA
HIT
X-
TRA/
OUTDOOR
METRAHIT
TECH
METRAHIT
PRO
METRA
HIT
BASE
V AC / Hz TRMS
(Ri 9 MΩ)
& Filter
& Filter
& Filter
V AC TRMS
(Ri = 1 MΩ)
& Filter
& Filter
& Filter
V AC+DC TRMS
(Ri 9 MΩ)
••••
V DC (Ri 9 MΩ)
••••
... 1 MHz 5 V AC
———
Duty cycle as %
———
Hz (V AC)
... 100 kHz ... 100 kHz ... 100 kHz ... 100 kHz
Bandwidth, V AC
15 Hz ... 20 kHz 15 Hz ... 10 kHz 15 Hz ... 10 kHz 15 Hz ... 1 kHz
A AC / Hz TRMS
100 μA
1/10/100 mA
1 A / 10 (16) A
10/100 mA
1 A / 10 (16) A
1 A / 10 (16) A
A AC+DC TRMS
A DC
Fuse
10 A/1000 V 10 A/1000 V 10 A/1000 V
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
Transformation factor
A AC / Hz TRMS
mV/A
mA/A
mV/A
Ri = 1 MΩ
A AC+DC TRM
S
mV/A
mA/A
mV/A
Ri = 1 MΩ
A DC
mV/A
mA/A
mV/A
Ri = 1 MΩ
Hz (A AC)
... 30 kHz ... 30 kHz ... 30 kHz ... 30 kHz
Resistance Ω
••••
Continuity
••••
Diode ... 5,1 V
••••
Temperature TC (K)
••••
Temperature RTD
———
Capacitance
••——
MIN/MAX / data hold
••••
4 MBit memory
1)
———
IR Interface
———
Power pack adapter
socket
———
Protection
IP52 / IP65 IP52 IP52 IP52
Measuring category
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
Function
SECU
LIFE
HIT
METRA
HIT
X-
TRA/
O
UTDOOR
METRAHIT
T
ECH
METRAHIT
P
RO
METRA
HIT
B
ASE
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT X-TRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT X-TRA in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT X-TRA

Gossen Metrawatt METRAHIT X-TRA User Manual - Dutch - 70 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info