590625
47
Zoom out
Zoom in
Previous page
1/74
Next page
GMC-I Messtechnik GmbH 47
V/Hz/dB – Ω, Temperature, and A/Hz Measurements
5.7.5 Alternating Current Measurement with Current Clamp Transformer,
A AC and Hz
Current/Current Transformer Output
When a current clamp transformer is connected to the multimeter
( mA/A input), all current displays appear with the correct value
in accordance with the selected transformation ratio. The only
prerequisite is that the current transformer is equipped with at
least one of the below listed transformation ratios, and that the
ratio has been previously selected in the following menu (Cl ip
0FF) (see also section 6.4).
Current Clamp Setup Menu
1nFo
... SET t iME ... CLIP
CLIP
set:1 / 10/100/1000 / 0ff 
(default setting: Cl ip = 0FF)
Transforma-
tion ratios:
CL IP
DMM Measuring Ranges Clamp Types
30 mA AC 300 mA AC 3 A AC *
1:1
1mA/1mA
30.000 mA 300.00 mA 3.0000 A
WZ12A, WZ12D,
WZ11A, Z3511,
Z3512, Z3514
1:10
1mA/10mA
300.00 mA 3.0000 A 30.000 A
1:100
1mA/100mA
3.0000 A 30.000 A 300.00 A
1:1000
1 mA/1 A
30.000 A 300.00 A 3000.0 A
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
1:1000
1:1000
A~
Hz
A~
Hz
003.50
A
AC
TRMS
050.100
Hz
FUNC
ENTER
003.50
COM
V
Temp
Ω
A
~
R
x
Current
R
i
mA
1:1000
1:1000
A~
Hz
A~
Hz
A
AC
TRMS
FUNC
ENTER
R
i
50 m
Ω
, 0,65
Ω
, 5,5
Ω
0
.
00000
A
AC
TRMS
AC
TRMS
055
.
000
Hz
24. C
*
24. C
*
Hz
A
*
Additional temperature display
(internal temperature at jacks)
in the 3 A range
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT ULTRA BT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT ULTRA BT in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info