590607
14
Zoom out
Zoom in
Previous page
1/72
Next page
14 GMC-I Messtechnik GmbH
Operating Overview – Connections, Keys, Rotary Switch, Symbols
Symbols used for Rotary Switch ositions
Switch
FUNC
Display Measuring Function
V~ 0/4 V~ AC TRMS Alternating voltage, AC TRMS, full bandwidth
Hz (V) 1 Hz ~ AC Voltage frequency, full bandwidth
V~ 2 V Fil ~ AC TRMS Alternating voltage, AC TRMS, with low pass filter (200 Hz)
Hz (V)
3 Hz Fil ~ AC Voltage frequency, with low pass filter (200 Hz)
V 0/2 V DC Direct voltage
V 1 V DC AC TRMS Pulsating voltage, TRMS ( )
R
SL
0/3 RPE Ω Loop impedance measurement with acoustic signal where I is constant
1 Ω Continuity test with acoustic signal
2
V DC Diode voltage where I is constant
Ω
0/2 Ω (DC) resistance
Temp. RTD 1 °C Pt 100/1000 Temperature with Pt 100 / Pt 1000 resistance thermometer
0/2 nF Capacitance
m (km) 1 m (km) Cable length (via capacitive linear electric constant)
a-b, a-E, b-E
0/2 V Extraneous voltage test
M
Ω
ISO
@100V
1 ISO 100 V / kΩ / MΩ Insulation resistance measurement:
A 0/2 A DC Direct current value
A 1 A DC AC TRMS Pulsating current amperage, AC DC TRMS
A~ 0/2 A~ AC TRMS Alternating current amperage, AC TRMS
Hz (A) 1 Hz ~ AC Current frequency
0/2 A DC DC amperage with AC DC clip-on current sensor, 1 V:1/10/100/1000 A
1 A DC AC TRMS Pulsating current amperage, TRMS, with AC DC clip-on current sensor,
see above
0/2 A~ AC TRMS Alternating current amperage, TRMS, with clip-on current sensor, see
above
Hz ( ) 1 Hz ~ AC Current frequency with clip-on current sensor, see above
200 Hz
200 Hz
V
ACDC
V
AC
2
V
DC
2
+=
A
A
A
A
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT T-COM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT T-COM in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Quick start guide - English, German - 2 pages

Gossen Metrawatt METRAHIT T-COM Quick start guide - Dutch - 3 pages

Gossen Metrawatt METRAHIT T-COM User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info