571684
7
Zoom out
Zoom in
Previous page
1/12
Next page
GOSSEN-METRAWATT 7
Response time
Response time for 12S ... 16S, 14A (after manual range selection)
Power supply
Battery 9-V flat cell battery;
manganese-dioxide cell according
to IEC 6 F 22,
alkaline-manganese cell according
to IEC 6 LR 61
or corresponding NiCd storage battery
Operating time With alkaline-manganese cell:
METRAHit 12...16S, 14A:
approx. 750 hours on V , A
approx. 200 hours on V , A
(12S...15S, 14A)
approx. 150 hours on , A (16S)
with interface operation times x 0.7
METRAHit 18S:
approx. 300 hours on V
approx. 150 hours on V , A A
Battery test Automatic display of the „ symbol,
when the battery voltage drops below
approximately 7 V.
Fuses
Fuse link for the
ranges up to 300 mA FF 1.6/500 G; 6.3 mm x 32 mm;
switching capacity 20 kA on 500 V and
ohmic load; in connection with power
diodes protects all current measuring
ranges up to 300 mA
Fuse link for ranges
up to 10 A Switching capacity 100 kA on 600 V
and ohmic load; protects the 3 A and 10 A
ranges up to 600 V
Response time for 18S (after manual range selection)
Electrical safety
Protection class II according to IEC 348/DIN VDE 0411 and
IEC 1010-1/EN 61010-1/VDE 0411-1
Overvoltage category II III
Nominal voltage 1000 V 600 V
Degree of pollution 2 2
Nominal
insulation voltage 1000 V acc. to IEC 348 / DIN VDE 0411
Test voltage 6 kV~ acc. to IEC 348 / DIN VDE 0411
Electromagnetic compatibility EMC
Emission EN 50081-1:1992 /
EN 55022:1987 class B
Immunity EN 50082-1:1992
/ IEC 801-2:1991 8 kV air discharge
/ IEC 801-3:1984 3 V/m
/ IEC 801-4:1988 0.5 kV
Data interface
Type RS-232C, serial, according to DIN 19 241
Data transmission Optical, with infrared light through the case
Baud rate 8192 bit/s
Influence
quantity
Influence range
Meas. ranges
12S ... 16S
Damping
Common
mode voltage
Disturbance variable max. 1000 V V > 120 dB
Disturbance variable max. 1000 V
50 Hz, 60 Hz sinusoidal
3V ,
30 V
>80dB
300 V >70dB
1000 V >60dB
Normal
mode voltage
Disturbance variable V ,
nom. value of meas. range at a time,
max. 1000 V , 50 Hz, 60 Hz
sinusoidal
V > 50 dB
Disturbance variable max. 1000 V V > 110 dB
Measured quantity/
measuring range
Response time
Leap function of
the measured quantity
of analog
indication
of digital
display
V, V,
A , A
0.7 s 1.5 s
from 0 to 80 %
of the upper range limit
30 ...3M 1.5 s 2 s
from to 50 %
of the upper range limit
30 M 4s 5s
0.7 s 1.5 s
nF, µF, °C max. 1... 3 s
from 0 to 50 %
of the upper range limit
300 Hz, 3 kHz max. 2 s
30, 100 kHz max. 0.7 s
% (1 Hz) max. 9 s
% (10 Hz) max. 2.5 s
Influence
quantity
Influence range
Meas. ranges
18S
Damping
Common
mode voltage
Disturbance variable max. 1000 V V > 120 dB
Disturbance variable max. 1000 V
50 Hz, 60 Hz sinusoidal
300 mV ...
30 V
>80dB
300 V >70dB
1000 V >60dB
Normal
mode voltage
Disturbance variable V ,
nom. value of meas. range at a time,
max. 1000 V , 50 Hz, 60 Hz
sinusoidal
V > 48dB
Disturbance variable max. 1000 V V > 110dB
Measured quantity/
measuring range
Response time
Leap function of
the measured quantity
of analog
indication
of digital
display
V, V,
A , A
0.7 s
1.5 s
300 mV : 8 s
from 0 to 80 %
of the upper range limit
300 ... 3M 1.5 s 2 s
from to 50 %
of the upper range limit
30 M 4s 5s
0.7 s 1,5 s
3 nF ... 300 µF max. 2 s max. 2 s
from 0 to 50 %
of the upper range limit
3 000 µF max. 7 s max. 7 s
10 000 µF max. 14 s max. 14 s
>10 Hz max. 1.5 s max. 1.5 s
°Cmax. 3s
Analog-digital multimeters
METRA 12S ... 18S, 14A
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 14A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 14A in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info