GMC-I Messtechnik GmbH 17
4.5.2 Current measurement
Set the function switch to the I and/or I~ position and the selec-
tor switch for the current ranges to the range corresponding to the
measured value. The selector switch for the voltage ranges may be
set to any position.
Connect the current path to terminals I* (1) and I (3). Read the mea-
sured value off the scale corresponding to the measuring range
and multiply it by the factor of 0.01 (see table in chapter 5 „Specifi-
cations“).
4.5.3 Phase sequence indication
Set the function switch to the position.
Connect all of the 3 outer conductors in proper sequence to termi-
nals L1 (2), L2 (5) and L3 (8).
With correct phase sequence, the pointer deflects up to the mark-
ing (83 % of full deflection), with incorrect phase sequence up
to the marking (17 % of full deflection).
The interlinked voltages must be > 30 V and must not exceed 650 V.
The connected voltages may deviate from each other by a maxi-
mum of 5%.
L1L2L3
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt MAVOWATT 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt MAVOWATT 4 in the language / languages: English as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info