TR2500 Current Probe
TR2500 Current Probe
Guidelines
To achieve the rated accuracies, follow these guidelines:
The conductor must be at a right angle to the probe.
The conductor must be centered in the probe core.
The jaw contact surfaces must be clean and properly aligned.
Specifications
Range
: 1 to 500 Arms
Accuracy
:
48 to 400 Hz: ±1.5% reading ±0.6A
400 to 3000 Hz: ±3% reading ±0.8A
Working voltage
: 600 V max.
Frequency range
: 48 to 3000 Hz
Output signal
: 3 mV/A
Maximum conductor size
: 1.18" (30 mm)
Maximum bus bar size
: 2.5 x 0.20" (63 x 5 mm)
Phase shift (45 to 1000 Hz)
: Less than
Operating temperature
: 14 to 122 ºF (-10 to 50 ºC)
Storage temperature
: -40 to 158 ºF (-40 to 70 ºC)
Dimensions
: 2.60 x 7.68 x 1.34” (66 x 195 x 34 mm)
Weight
: 14.82 oz. (420 g)
NOTE
Current probe TR2500 can be used interchangeably with TR2500A.
171


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt MAVOWATT 20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt MAVOWATT 20 in the language / languages: English as an attachment in your email.

The manual is 2,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info