300095
If you have a tumble dryer of the same dimensions, you can place
it on top of the washing machine.
To ensure correct operation of the appliance, water
pressure inlet must be between 0,05 and 0,8 MPa.
Minimum water pressure can be established by measuring
the quantity of poured out water. 3 litres of water must be
poured out from completely opened tap in 15 seconds.
Take the water inlet hose from the drum and attach the inlet hose
angle extension (1) to the washing machine by screwing it onto
the provided thread (certain models only).
Insert the gasket with a lter net into the straight inlet hose
attachment nut (2) and screw the nut onto the water tap. (With
some models, the gasket with lter net is already tted and any
additional tting into the nut on the straight attachment is not
required).
If your model has connections for both hot and cold water, then
connect one hose to the cold water supply (blue wing nut or blue
mark on the hose) and the other one to the hot water supply (red
wing nut or red mark on the hose), as indicated on the back wall of
the appliance (letters C and H) (C - cold; H – hot).
The inlet hose should be tightened manually, rmly enough
to prevent any leaks. After tightening the hose, check for
any leaks.
Use of pliers, wrenches, or other similar tools is not
allowed when installing the hose, as these tools can
damage the nut thread.
Partial Aqua-stop (water stop system)
In case of damage on the interior pipe, leaking is prevented by
automatic closing system which stops water inlet to the machine. In
such cases display A turns red.
Inlet pipe must be replaced.
Complete Aqua-stop (certain models only)
In case of damage on the interior pipe, leaking is prevented by
automatic closing system which stops water inlet to the machine.
Security system also detects whether there is any water leakage
within the interior of the machine. In such cases washing is
suspended, machine switches on the pump and signals error.
Do not immerse the Aqua-stop system inlet pipe into the
water, because it contains the electric valve!
Water inlet connection
6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje WS53121 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje WS53121 in the language / languages: English as an attachment in your email.

The manual is 3,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info