326973
15
Zoom out
Zoom in
Previous page
1/18
Next page
179732
Instructions for use, installation and connection
16
Nozzle chart
Type of gas,
pressure
Auxiliary burner Normal burner Large burner Triple burner
Wobe number Standard Fast
max min max min max min max min max min
Natural gas H
Wo=45,7÷
Nominal heat input
(kW)
1 0,36 1 0,36 1,90 0,46 3 0,76 3,5 1,56
54,7 MJ/ m
3
, Consumption (l/h) 95,21 34,4 95,21 34,4 180,9 43,8 285,64 72,4 333,2 148,5
Natural gas E , Nozzle mark (1/100mm) 77 78 104 129 - 140
Natural gas E+
Wo=40,9÷
54,7 MJ/m
3
G20,
p=20mbar
Nozzle code 162081 162082 162083 162084 162085
Liquid gas 3+,
3B/P
Nominal heat input
(kW)
1 0,36 1 0,36 1,90 0,46 3 0,76 3,5 1,56
Wo=72,9÷
Consumption (g/h) 71,7 26,2 71,7 26,2 138,1 33,4 215,0 55,3 254,5 113,4
87,3MJ/m
3
G30
Nozzle mark (1/100mm) 50 29/24 50 29/24 69 33/26 87 43/33 93 57/57
p=30 mbar Nozzle code 162162 162162 162164 162165 162166
Built-in regulation knobs are intended for liquefied gas. In case of natural gas (municipal gas line) they need to be set according to
the required gas flow (unscrew for maximum 1,5 turn from the tightened position).
Nozzle code for minimum varies with different manufacturers. First digit from the pair represents IMIT, and the second one
COPRECI.
Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the gas distribution company or by the
authorized service!
Conversion to another type of gas
For the conversion procedure the appliance need not be
pulled out from its location.
Before starting to work on conversion, disconnect the
appliance from the mains.
Replace the existing nozzles of declared nominal heat input
with adequate nozzles for the new type of gas (see table).
Adjust the nozzle for the minimum heat input rate as long as
it requires to arrive at the minimum heat input.
Never unscrew nozzles for minimum heat input rate for more
than 1,5 turn.
After the conversion is done, stick the new sticker with the
actual gas specifications of the appliance over the old one.
Check that electrical cables, thermostat probe and thermal
elements are located away from the gas jet!
Setting elements
Elements for regulation of cooking burners are accessible
when the control panel is removed.
Remove the cooktop grid and burner crowns with caps.
Remove the control buttons.
Unscrew bottom tightening screws from the control panel
and remove the panel.
Cooking zone burner (fig. 1 )
1
1 Burner crown cap
2 Burner crown with
burner cap support
3 Thermal probe
4 Ignition plug
5 Nozzle
Triple-ring burner(fig. 2)
5 nozzles
Safety gas faucet (fig. 3)
13 Setting screw for
minimum heat input rate
Non-safety gas faucet (fig. 3a)
13 Setting screw for
minimum heat input rate
Elements to be replaced or reset when altering the type of
gas
Cooking zone burner Fig. number Element code
Nominal heat input
1,2 5
Minimum heat input
3, 3a 13
2
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje k 7708 e at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje k 7708 e in the language / languages: English as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info