After performing the maintenance, with the hood off and the button active, press the button for more than 3 seconds to perform the
reset of the lter saturation indicator; repeat the operation if necessary (for ex., when both lters are saturated).
Activationofthecharcoalltersaturationindicator
The saturation indicator of the charcoal lter is normally disabled. To activate it, proceed in the following manner:
With the display on (ON) and the suction off (OFF), press simultaneously the buttons T8 and T9 for more than 3 seconds; the button
T9 lights on with steady light for approx. 5 seconds, to indicate the activation.
To disable it, repeat the operation; the button T9 will ash for approx. 5 seconds to indicate the disabling.
Buttons T8 and T9 are not visible at this stage (on some models). They are visible only as described
in operation section of the manual.
Approximate distance of button T8 from T7 is 15 mm, and distance of button T9 from T8 is 40 mm.
Setting of Automatic Operation parameters
For correct use of the automatic operation, perform „Hood Calibration”.
Hood Calibration
With the display on (ON) and the suction off (OFF), press button T3 for 3 seconds.
The suction speed (power) 2 starts functioning and button T3 ashes to indicate that hood calibration is initiated and it will last for approx.
15 minutes.
Note: to interrupt the calibration, press T3 for 5 seconds; the calibration will be invalidated and should therefore be repeated.
IHT943A2XBG, IHT963S2X
To select the functions of the hood press on the symbol. Function will be activated when symbol will be released.
T1. Standby mode (the control panel off – all functions disabled) / ON (control panel switched on)
Note: After about a minute of inactivity (suction and lights), the hood will automatically switch to standby.
T2. ON/OFF lights
On certain models only (see drawing above):
press repeatedly to select the desired light intensity:
L1: low light
L2: medium light
L3: high light
Press again to turn off the lights.
T3. ON/OFF Automatic operation “AdaptTech”.
The hood automatically sets the suction speed (power) 1 to increase if the environmental conditions detected by the hood sensor
require it.
If there are no variations in the environmental conditions, after 10 minutes (if the hood is already in suction speed (power) 1), the hood
turns off.
Note: for a correct use of this function, rst perform the „Setting of the parameters for Automatic Operation” (see corresponding
paragraph).
Note: During automatic operation, if the user acts on the other functions that adjust the speed, auto ventilation function is switched off.
T4. Manual selection of the suction speed (power):
L4: suction speed (power) 1
L5: suction speed (power) 2
L6: suction speed (power) 3
Press again to turn off the hood (OFF).
Note: manual selection excludes any other suction related set function.
T5. ON/OFF Intensive suction speed (power) “POWER BOOST” (timed)
Note: After 5 minutes of operation the hood returns to its previous state.
T6*. (Only certain models ON/OFF intensive suction speed (power) “POWER BOOST x 2” (timed)
Note: After 5 minutes of operation, the hood goes back to the previous status.
T7. ON/OFF operation mode „ReFresh”.
Every 50 minutes of inactivity, the suction speed (power 1 is turned on for 10 minutes.
T8. ON/OFF Timer of the suction speed (power) (approx. 30 minutes)
Note: this function is available for the speeds that can be selected with button T4.
T9. Indicatorandresetltersaturation
The button lights on automatically with steady light when it is necessary to perform the grease lter maintenance.
The button lights on automatically with ashing light when it is necessary to perform the charcoal lter maintenance.
After performing the maintenance, with the hood off and the button active, press the button for more than 3 seconds to perform the
T1 T2 T3 T4 T5 T6 T7 T8 T9
L1 L2 L3 L4 L5 L6
T7 T8 T9
15 mm 40 mm
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje IHT943A2XBG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje IHT943A2XBG in the language / languages: English, German, Dutch, French, Italian, Portuguese, Turkish, Spanish as an attachment in your email.

The manual is 6,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info