444650
Gas type, pressure Auxiliary
burner
Normal
burner
Large burner Double
burner
max min max min max min max min
Natural gas H
Wo=45,7÷54,7 MJ/ m
3
,
Natural gas E, E+
Wo=40,9÷54,7 MJ/m
3
G20,
p=20mbar
Rated power
(kW)
1 0,36 1,9 0,46 3 0,76 3,5 1,56
Gas
consumption
(l/h)
95,21 34,4 180,9 43,8 285,64 72,4 333,2 148,5
Nozzle type
(
μm
) / Bypass
No.
78 24 104 26 129 33 135 57
Nozzle ID 431006 162083 431008 431245
Liquid gas 3+, 3B/P
Wo=72,9÷87,3MJ/m
3
G30
p=30 mbar
Rated power
(kW)
1 0,36 1,9 0,46 3 0,76 3,5 1,56
Gas
consumption
(g/h)
71,7 26,2 138,1 33,4 215 55,3 254,5 113,4
Nozzle type
(
μm
) / Bypass
No.
50 24 69 26 87 33 93 57
Nozzle ID 162162 162164 162165 162166
• Regulation valves that are factory-built-in are intended for liquid gas; however, the
valves are set for operation with the type of gas for which the appliance is factory-
preset.
• When adapting the appliance for use with another type of gas, the regulation screw
(valve) should be fastened or release to correspond with the required gas fl ow /
throughput (however, the regulation screw should not be released more than by 1.5
rounds from the position in which it is completely fastened).
Burner power is indicated by observing the upper Hs caloric value.
Warning: these tasks may only be carried out by a qualifi ed technician, authorized by
the gas distributing company or authorized service center!
24
NOZZLE TABLE
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje GW6N41 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje GW6N41 in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gorenje GW6N41

Gorenje GW6N41 Usermanual and installation guide - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info