603566
6
Zoom out
Zoom in
Previous page
1/13
Next page
7
When connecting, the knee R1/2 should be held firmly to prevent it from rotating.
• For sealing of the connection joints, use a non-metal approved gaskets and
approved sealants.
• The gaskets should only be used once. The thickness of the flat non-metal gaskets
should not be deformed more than by 25 percent.
• To connect the appliance to the gas supply, use a tested and certified flexible hose.
• The flexible connection hose should be able to move freely.
It should not come into contact with the movable parts of the furniture or the bottom
of the cooking hob.
• If an electric oven is built into the kitchen element under the cooking hob, it should
be fitted with a cooling fan.
After connecting the gas hob, check the joints for any leaks.
Gas supply connection plug
A ISO7-1 R1/2 connection plug
B Non-metal gasket with thickness of 2 mm
C Pipe adapter for liquid gas (depending on the model)
Only use pipes and seals in accordance with the Standards. These pipes must
be installed so that, when fully extended, their length does not exceed 2000 mm. For
easier installation and to prevent gas leaks, attach the swivel coupling to the cook
top first, and then to the gas mains pipe. Inverting this sequence may hamper the
gas seal between the pipe and the cook top.
Important: when the installation is complete, check that all couplings are
completely sealed by using a soapy solution. Never use a flame. Also ensure
that the flexible pipe cannot come into contact with any moving part of the
cook top (e.g. drawer) and that it is not in a position where it could be
damaged.
After the connection, check the burners for correct operation.
The flames must be clearly visible, and should be blue and green at the center. If the
flame is unstable, increase the minimum power.
Adaptation to a different
type of gas
• The procedure or adaptation of the cooker to another type of gas does not require
removal of the appliance from the worktop.
• Before adapting, disconnect the appliance from the power mains and close the gas
supply valve.
• Replace the existing nozzles for nominal thermal load with corresponding nozzles
for the new gas type and supplied provided (see table below).
• After finishing this sequence, replace the old setting label with the new one
provided for the new injectors.
Adjustment elements
To leave the adjustment elements accessible, please observe the following
instructions:
• Remove the support grid and burner covers with respective crowns.
• In double burners, adjustment elements are accessible behind the main nozzle
protective plate.
• Remove the control knobs, including the gaskets.
Gas valve
Minimum thermal load regulation valve
Minimum flow adjustment
Instructions for urban (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the gas tap knob and turn the adjustment screw on the side of the tap
rod:
anti-clockwise to increase the gas flow
clockwise to reduce the gas flow
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje GW65 CLI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje GW65 CLI in the language / languages: English as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gorenje GW65 CLI

Gorenje GW65 CLI User Manual - German - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info