728588
35
Zoom out
Zoom in
Previous page
1/40
Next page
CONNECTION DIAGRAM:
Jumpers (connecting bridges) are placed in the dedicated slot on
the clamp.
POWER CORD
The following may be used for connection:
• PVC insulated connection cables type H05 VV-F or H05V2V2-F
with yellow-and-green protective conductor, or other equivalent
or superior cables.
Normal connection
• 2 phases, 1 neutral conductor (21N, 380-415V~/50Hz):
Voltage between phases and neutral conductor is 220-240V~.
Voltage between the two phases is 380-415 V~. Install a jumper
between the terminals 4–5. The group should include at least
two 16-ampere fuses. Diameter of the power cord core should
be at least 1.5mm
2
.
• 2 phases, 2 neutral conductors (22N, 220-240V~/50Hz):
Voltage between phases and neutral conductors is 220-240V~.
The group (installation) should include at least two 16-ampere
fuses. Diameter of the power cord core should be at least
1.5mm
2
.
Special connection:
• Single-phase connection (11N, 220-240V~/50Hz):
Voltage between phase and neutral conductor is 220-240V~.
Install jumpers between the terminals 1–2 and 4–5. The group
(installation) should be fi tted with a fuse of at least 32A.
Power cord core diameter should be at least 4mm
2
.
Run the power cord through a cord strain relief (clamp) which
protects the cable from being pulled out. Make sure the cable on
the rear side of the appliance is not in contact with the cooking
hob rear wall, as this part can heat up during use.
After connecting the appliance, switch on all heaters for
approximately 3 minutes to check their operation.
False connection can destroy parts of the appliance. In such case,
there is no right to warranty.
Before connecting the appliance, make sure the voltage specified
on the rating plate conforms to the voltage of the power mains.
An expert should check the actual voltage in your home (220-
240V relative to N), using a suitable meter!
Appliances with a width of 30 centimetres (two cooking zones)
only allow single-phase connection. The diameter of the power
cord should be at least 1.5mm!
L2
380-415V
L1
N
N
PE
L2
220-240V
L1
N
N
PE
220 - 240 V ~
N
L
PE
35
719386
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje GHT647X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje GHT647X in the language / languages: English as an attachment in your email.

The manual is 2,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info