603658
22
Zoom out
Zoom in
Previous page
1/24
Next page
7.5.201521212020
20
Setting screws are intended for liquid gas. For natural (municipal) gas supply new
setting of gas flow is required (unscrew for not more than 1.5 turn from the end
position).
** Double burner has three nozzles. Left column nozzle must be fitted to the center of the
burner, while the right column nozzle must be fitted at the side of the burner (2 pieces).
Burner power is indicated according to the upper caloric value of Hs gas.
Caution: above works may be performed only by the expert, authorized by the gas
distributor or authorized service!
After gas conversion procedure, stick a new rating plate over the old one, and check
again the sealing of all gaskets and the functionality of the appliance.
GB
Type of gas
Double burner (Wok)
Number Wobbe
max
min-
interior
flame
min -
intermediat
e and
exterior
flame
Natural gas H
Ws= 45,7÷54,7 MJ/m
3
Natural gas E, E+
Ws= 40,9÷54,7 MJ/m
3
G 20, p = 20 mbar
Nominal heat input (kW)
0,8/4,2
0,36
1,9
Consumption (l/h)
76,2/400,2
34,3
181,0
Nozzle mark (1/100mm)
70H1
147H3
Nozzle code
438921
438922
Liquid gas 3+, 3B/P
Ws= 72,9÷87,3 MJ/m
3
G 30, p = 28-30 mbar
Nominal heat input (kW)
0,8/4,2
0,36
1,9
Consumption (g/h)
58,2/305,6
26,2
138,3
Nozzle mark (1/100mm)
44
95
27
66
Nozzle code
438974
438975
Liquid gas 3+, 3B/P
Ws= 72,9÷87,3 MJ/m
3
G 31, p = 37 mbar
Nominal heat input (kW)
0,8/4,2
0,36
1,9
Consumption (g/h)
57,2/300,2
25,7
135,8
Nozzle mark (1/100mm)
44
95
27
66
Nozzle code
438974
438975
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje GC341 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje GC341 in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info