326971
22
Zoom out
Zoom in
Previous page
1/26
Next page
Instructions for use and installation
78
Nozzle specifications
Auxiliary
burner
Normal
burner
Large burner
Doppelbrenner*
Double burner Infra
burner
max min max min max min max min max min max
Natural gas H,E
p=20 mbar
Nominal heat
input (kW)
1 0,32 1,65 0,40 3 0,70 3,3 1,5 3,5 0,80 2,7
Wo=40,9÷
54,7 MJ/ m
3
Natural
Consumption
(l/h)
100 29 160 37 284 64 314 143 339 71 259
gas L
p=25 mbar
Wo=39,1÷
Nozzle number
(1/100 m)
76
94
128
63 118
130
120
44,8 MJ/ m
3
Nozzle code 609302 609300 609301 642006 642007 609288 609287
Liquid
gas
3+, 3B/P
Nominal heat
input (kW)
1 0,32 1,65 0,40 3 0,70 3,3 1,5 3,5 0,80 2,7
p=30 mbar
Wo=72,9÷
Consumption
(g/h)
71,7 21,8 118,3 27,6 215,0 48,7 240 109 250,9 54,5 193,5
87,3MJ/m
3
Nozzle number 50 29/24 65 33/26 85 43/33 37 86 57 90 42/42 81
Nozzle code 609254 609271 609272 642008 642004 609290 609289
Built-in regulation knobs are intended for liquefied gas. In case of natural gas (municipal gas line) they
need to be set according to the required gas flow (unscrew for maximum 1,5 turn from the tightened
position).
Double burner has two nozzles. The nozzle in left column is to be fitted in the centre of the burner, while
the nozzle in the right column is to be fitted at the side of the burner.
Nozzle code for minimum varies with different manufacturers. First digit from the pair represents IMIT, and
the second one COPRECI.
Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the gas distribution
company or by the authorized service!
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje g 4704 w at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje g 4704 w in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info