603619
9
Zoom out
Zoom in
Previous page
1/56
Next page
9
75cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation instructions.
Warning: Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
The cooker hood may be installed on the wall or on the base
of a cabinet; if supplied, use the hole gauge H to drill the
correct distance, otherwise lean the cooker hood on the wall
or on the base of the cabinet and mark the holes with a pencil.
Wall mounting - Insert the wall screw anchors J in the drilled
holes and the two K screws in the upper drill holes, remove
the grill and hook the cooker hood to the 2 screws, finally from
the inside, insert the third screw L and lock them all in.
Cabinet fixing - Affix the cooker hood with the 4 M screws
from inside the cabinet.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Always open the vapour catcher N*.
If your product is provided with an electrically or mechanically
activated valve, the keys and/or the buttons and/or the
handles available are for controlling the lights and for opening
and closing the valve.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire
risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles.
If situated inside the support grill, it may be one of the
following types:
Paper filter must be replaced once a month or if colouring
appears on upper side, in such cases the colouring is evident
through the grill openings.
Sponge filter should be washed with hot soapy water once a
month and replaced every 5 to 6 washes.
Metallic filter must be cleaned once a month, with non
abrasive detergents, by hand or in dishwasher on low
temperature and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
In order to remove the grease filter open the grill via the P
hooks and free the R1 or R2 stoppers.
The self-supporting metal filter does not include a support
grill, in order to remove the filter – pull the release springs P4
backwards and slide the filter downwards.
Charcoal filter (filter version only)
It absorbs unpleasant odours caused by cooking.
The saturation of the activated charcoal occurs after
more or less prolonged use, depending on the type of
cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least
every four mounths.
The carbon filter may NOT be washed or regenerated.
It may be one of the following types:
Rectangular S1 or S2 or S3:
Mounting (S1 or S2) : insert the rear side T and hook further
to the front (U).
Mounting (S3): Remove the cover W by rotating the O knobs
to 90° , then close the cover. Proceed in the inverse for
dismounting.
Circular (V1-V2-V3-various models):
Bayonet mount position the filter in the middle of the motor
protection grill covering ensuring that the reference to X1 or
X2 or X3 on the carbon filter match the Y1 or Y2 references
on the conveyor, then turn clockwise; in case of dismounting
turn anticlockwise, if provided with a Z tape remember to
gently lift first.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gorenje DU6111 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gorenje DU6111 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 2,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info