44115
6
Zoom out
Zoom in
Previous page
1/18
Next page
10
9
To the 1st
push b. or to the P terminal of the 1st
EL516.
To the next push b. or to the P terminal of the 2
nd EL516.
To the next push b. or to the P terminal of the 3rd
EL516.
To the next push b. or to the P terminal of the 4
th
EL516.
To the next push b. or to the P terminal of the 5th EL516.
To the next push b. or to the P terminal of the 6th
EL516.
To the next push b. or to the P terminal of the 7
th EL516.
To the last push b. or to the P terminal of the 8th
EL516.
To the push b. common terminal and to the EL516 CP terminal.
To the B terminal of the EL516 encoders.
ush buttons limit.
P
ush buttons digital code.
P
ush buttons wiring.
P
The enclosed drawing shows an example of connection between the EL500 circuit and two
EL516 with their corresponding push buttons.
The codes shown on the first column (shadowed) correspond with the push buttons
directly connected to the corresponding terminal on the CN2 terminal connector
of the EL500 circuit, or with the terminal 1 of its corresponding EL516 encoder.
The maximum number of push buttons to be connected depends on the number of installed
EL516 encoders, as it is shown on the following chart:
Without EL516 circuits:
With 1 EL516 circuit:
With 2 EL516 circuits:
With 3 EL516 circuits:
With 4 EL516 circuits:
With 5 EL516 circuits:
With 6 EL516 circuits:
With 7 EL516 circuits:
With 8 EL516 circuits:
8
7 + 15 = 22
6 + 15 + 15 = 36
5 + 15 + 15 +15 = 50
4 + 15 + 15 + 15 +15 = 64
3 + 15 + 15 + 15 +15 + 15 = 78
2 + 15 + 15 + 15 +15 + 15 + 15 = 92
1 + 15 + 15 + 15 +15 + 15 + 15 + 15 = 106
0 + 15 + 15 + 15 +15 + 15 + 15 + 15 +15 = 120
To other
encoders
or
push buttons
1
P2
1
P1
31
P4
61
P6
91
P8
16
P3
46
P5
76
P7
106
2
2
32
62
92
17
47
77
107
3
3
33
63
93
18
48
78
108
4
4
34
64
94
19
49
79
109
5
5
35
65
95
20
50
80
110
6
6
36
66
96
21
51
81
111
7
7
37
67
97
22
52
82
112
8
8
EL516 terminals
EL500 terminals
38
68
98
23
53
83
113
9
9
39
69
99
24
54
84
114
10
10
40
70
100
25
55
85
115
11
11
41
71
101
26
56
86
116
12
12
42
72
102
27
57
87
117
13
13
43
73
103
28
58
88
118
14
14
44
74
104
29
59
89
119
15
15
45
75
105
30
60
90
120
DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
In case to combine these door panels with coded door panels or porter's exchange
it will be necessary to know these codes for a properly system configuration.
P8 P7 P6
CN2
P5 P4 P3 P2 P1CPB
P8 P7 P6 P5 P4 P3 P2 P1CPB
CN2
2 23 34 45 56 67 78 89 910 1011 1112 1213 1314 1415 15P PCP CP1 1B B
The CN2 connector of the EL500 microprocessed circuit has
8 terminals (P1 to P8) for the connection of push buttons
or EL516 encoders. The CP terminal of the EL500 circuit
must be connected to the push buttons common terminal
and to the CP terminal of the push buttons encoders.
Connect B terminal to the B terminal of the encoders.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar Plateau Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar Plateau Plus in the language / languages: English as an attachment in your email.

The manual is 5,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Golmar Plateau Plus

Golmar Plateau Plus User Manual - Dutch - 1 pages

Golmar Plateau Plus User Manual - Dutch - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info