642179
13
Zoom out
Zoom in
Previous page
1/24
Next page
INSTALLATIE SCHEMA:
Kit voor 1 woning (Kit N5110 VESTA) monitoren parallel (In-Uit) met Golmar gelijkspannings deuropener.
13
Kit voor 2 woningen (Kit N5220 VESTA) monitoren parallel (In-Uit) met Golmar gelijkspannings deuropener .
Configureer de laatste
monitor doormiddel van de
eindweerstand.
Dip 6 op On.
*
Belangrijk: Voor aansluiten van AC deuropeners of een 2e deuropener, (zie pagina 16).
(1)
Afstanden en diameters:
Twisting 2x0.75mm
Twisting 2x1mm
60m
A
60m
B
10m
C
80m 80m 15m
Kabel diameter
2
2
FA-GB2
VESTA
A
B
C
VESTA
Configureer de laatste
monitor doormiddel van de
eindweerstand.
Dip 6 op On.
*
FA-GB2
VESTA
A
B
Twisting 2x0.75mm
Twisting 2x1mm
60m
A
60m
B
10m
C
80m 80m 15m
Kabel diameter
2
2
C
Afstanden en diameters:
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
Deuropener
máx. 12 Vcc/270mA.
N N L N.A
CN1CN2
Internal
rele
BUS (M) BUS (PL)
FA-GB2
ON
1 2 3 4 5 6
AP
SW1
(1)
(1)
Buitendeurpaneel
VESTA
BUS
CODE 1
VESTA
BUS
CODE 2
VESTA
BUS
CODE 3
BUS
CODE 0
VESTA
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
Deuropener
máx. 12 Vcc/270mA.
N N L N.A
CN1CN2
Internal
rele
BUS (M) BUS (PL)
FA-GB2
ON
1 2 3 4 5 6
AP
SW1
(1)
(1)
Buitendeurpaneel
VESTA
BUS
CODE 1
VESTA
BUS
CODE 16
VESTA
BUS
CODE 17
BUS
CODE 0
VESTA
APPARTEMENT 1APPARTEMENT 2
*
*
BELANGRIJK: Maximaal 4 monitoren parallel (zonder splitters) per installatie.
BELANGRIJK: Maximaal 4 monitoren parallel (zonder splitter) per installatie.
APPARTEMENT 1
Master Slave
Slave Slave
SlaveMasterSlaveMaster
DEURVIDEO KIT GB2 NEXA MODULAIR - VILLA
Netstroom
100~240V AC
Netstroom
100~240V AC
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar KIT GB2 NEXA MODULAIR - VILLA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar KIT GB2 NEXA MODULAIR - VILLA in the language / languages: Dutch as an attachment in your email.

The manual is 6,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info