120
DOOR PANEL PROGRAMMING
ccess control menu.
A
3rd code on
07:15
3rd code off
14:55
07:15
modify value
10:13
3rd code on
O.K.
3
10
1
Proceed as described on "1st code" to modify
the fourth code. When this code is used
to activate the lock release, the system sends
an alert message to the porter's exchange
(if exists).
panic code
:5555
O.K.
Defines the starting time from which
it's possible to activate the lock release
by entering the third code.
To set this time press : the display will show
the message modify value. Key in
the hour value from 0 to 23 and minutes
value from 0 to 59 and confirm by pressing
. If is pressed the former value
will be restored.
For a proper operation of this function,
the system clock must be correctly adjusted,
as described on page 116.
Coming from previous page
Continue
Defines the closing time from which
it's possible to activate the lock release
by entering the third code.
To set this time proceed as described on the
previous menu.
In case that starting and closing times have
equal values, the third code will be enabled
all the time.
End of the access control menu. Use "UP" arrow key to move to the previous options.
Press to exit from the access control menu and return to the main menu.
If is pressed twice the panel will exit from the programming menu.
DOOR PANEL PROGRAMMING
121
repertory:new
enter address
O.K.
:000
O.K.
2
01
9
04300
enter direct cod
:000000
O.K.
_
enter name
setting recorded
repertory
O.K.
epertory menu.
R
NOTE: to make a call it will not be necessary to enter the zero placed on the left side
of the call code. For instance, if the call code is 000100, it will be enough to
enter 100 to make the call.
Coming from previous page
Continue
To enter into repertory menu, follow
the steps described on page 114
and press when the display shows the
message repertory.
Allows to enter a new entry in the last repertory
position. To choose a specific position,
use the repertory:insert menu.
Press to proceed: the display will show
the message enter address; key in the
monitor code and confirm by pressing .
If the panel has been configurated as general
entrance door panel, a six digits code must
be entered: the three first digits will match the
internal building code and the three last
digits will match the monitor code.
If the panel has not been configurated as
general entrance door panel, a three digits
code will be required, that will match the
monitor code.
IMPORTANT: if "Direct Call Code" function
has been enabled (page 116), the display
will show the message enter direct cod;
enter the six digits code that will be used
to call to this apartment.
Press to validate it.
To assign a text to this entry press and
proceed as described on page 124.
Once the new entry has been recorded
the display will show the message
settings recorded, and will return
to the initial screen. Repeat this procedure
to add as much entries as it is needed.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar 5403 Stadio Plus - T3403ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar 5403 Stadio Plus - T3403ML in the language / languages: English as an attachment in your email.

The manual is 7,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Golmar 5403 Stadio Plus - T3403ML

Golmar 5403 Stadio Plus - T3403ML User Manual - English - 160 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - Dutch - 24 pages

Golmar 5403 Stadio Plus - T3403ML Installation Guide - Dutch - 52 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - French, Spanish - 160 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info