DOOR PANEL PROGRAMMING
rogramming menu.
P
golmar
16:30
Access control options can be changed on
this menu. Press to enter into this menu.
access control
This menu allows to fill the repertory and
to change its options.
Press to enter into this menu.
repertory
Continue
pin code
pin:____
1 5 or
31
1 1
11
On this menu the system configuration options
can be changed.
Press to enter into this menu.
configuration
*
O.K. ANCEL
C
It will be necessary to enter into the programming menu to configure the system properties.
For a proper system operation, the menus marked with an asterisk must be configurated.
Two different programming menues are available: installer, that allows to modifiy any of the
system properties and user, that only allows changes that do not affect the system operation.
Programming options with black text and white background are availables in both menues;
options with white text and black background are only availables on installer menu.
The first time you enter into the programming menu, the display messages will appear in spanish.
Press OK when the display shows the message configuracion: the display will show now
castellano. Press OK to change to english or till the desired language appears.
If the option Direct Call Code (page 116) is disabled, it will not be necessary to fill the repertory
name for a proper system operation.
Use the arrow keys to move through the programming menu. Option changes will be validate
by pressing key, even if key is pressed later.
Use key to exit from the configuration menu. The door panel will automatically exit
from the configuration menu after 90 seconds with no operation.
To enter into the main programming menu,
press key symbol and enter
the installer PIN code (factory default: 1315)
or the user PIN code (factory default: 1111).
DOOR PANEL PROGRAMMING
115
onfiguration menu.
C
Continue
Coming from previous page
configuration
:000
panel address
modify value
:000
O.K.
:015
panel address
*
yes
general panel
*
yes
master panel
*
english
yes
panel w. camera
*
To enter into configuration menu, follow
the steps described on the previous page
and press when the display shows the
message CONFIGURAtION.
O.K.
O.K.
5
10
Allows to choose the language of the displayed
messages and the programming menues.
To choose a different language press
until the desired language will be displayed.
Each system must have one master panel only;
the rest of panels must be slave.
In systems with general entrance panel
configure as master one panel of each
internal building.
Press to change this value.
If this panel is a general entrance door panel
select YES.
Press to change this value.
Sets the building code. In buildings with
more than one panel, set them with the
same code; in systems with general entrance
panel, set 0 code for the general entrance
panel and a different code for each internal
panel (valid codes are from 1 to 255).
To change this value press : the display
will show the message modify value.
Key in the new building code and confirm
by pressing .
If is pressed the former value will be
restored.
Note: To visualize in the porter´s exchange the
general entrance door panel that has made
the call, contact with your distributor.
If this panel is a video door panel select YES.
Press to change this value in case of
audio door panel only.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar 5403 Stadio Plus - T3403ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar 5403 Stadio Plus - T3403ML in the language / languages: English as an attachment in your email.

The manual is 7,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Golmar 5403 Stadio Plus - T3403ML

Golmar 5403 Stadio Plus - T3403ML User Manual - English - 160 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - Dutch - 24 pages

Golmar 5403 Stadio Plus - T3403ML Installation Guide - Dutch - 52 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - French, Spanish - 160 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info