SYSTEM CHARACTERISTICS
UPDATED FEATURES FROM 5.00 VERSION
STARTING RECOMMENDATIONS
O Management of up to 255 internal buildings of 1,000 apartments each.
O New programming menu structure.
O Direct Call Code that allows to use a different call code from the one recorded on the monitor or
telephone (page 116).
O 'Repertory:insert' function, that allows to keep sorted the repertory content (page 122).
O Transmission of the repertory content to other panels or porter's exchanges through the
installation wires (page 123).
O Third access control code with time restriction (page 120).
O Text edition using the keypad as a mobile phone (page 124).
O Previous software versions are fully compatible, except when the Direct Call Code is
activated or the number of internal buildings is bigger than 99.
106
O
O
O
O
O
Do not use excessive force when tightening the power supply connector screws.
Install the equipment without the power connected. Disconnect from power before any system
modification. Check that the input voltage is lower than 230Va.c.
Before to connect the system, check the connections between door panel, monitors and
telephones, and the transformer connection. Do always follow the enclosed information.
Each time the power supply is restarted, or after a modification, the system will remain blocked
during 30 seconds.
Always use RG-59 or RG-11 coaxial cables. Never use coaxial antenna cable. In
installations no longers than 100m., Golmar RAP-5130 cable can be used.
O Microprocessed systems with bus installation (no call wires):
wAudio system with 4 common wires installation.
wVideo system with 3 common wires plus coaxial cable.
wVideo system with 4 common wires plus twisted pair cable.
O Unlimited number of door panels being not necessary the use of switching units.
Acoustic busy channel and call acknowledgement signals.
d.c. lock releases activation.
Timed door open activation.
In Platea Uno monitors or T-940 Uno and T-740 Uno telephones:
wPrivacy on audio and video communications.
w'Video-Spy' function remaining the communication channel free.
wInput for door bell apartment push button.
wUp to three monitors or telephones in the same apartment without additional power supplies.
wIn Platea Plus monitors or T-940 Plus telephones, besides the aforementioned characteristics:
wIntercommunication function with other monitor or telephone of the same apartment.
wDifferent call reception tones depending where the call is comming from: main or slave door
panels, door bell push button, intercom, ....
wActivation of two auxiliary devices: secondary telecamera, courtesy light, ...
O
O
O
O
SYSTEM OPERATION
One building systems.
O To make a call, the visitor should key-in the three digits code corresponding to the apartment he
wishes to contact: the door panel display will show the sequence keyed-in. Once the code has
been introduced, press bell key to confirm the call: acoustic tones will be heard confirming the call
is in progress and the door panel display will show the message calling. At this moment the
call will be received at the monitor (telephone) in the dwelling. If an incorrect code has been
keyed-in, press key and try again.
In systems with several access doors, the other(s) door panel(s) will be automatically disconnected:
if a visitor tries to call from other door panel an acoustic tone will be heard confirming the system
is busy and the door panel display will show the message busy.
The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will
appear on the master monitor without the visitor being aware of this. To see the picture in a slave
monitor press the push button, dissapearing the picture on the other monitor. If the call is not
answered in 45 seconds, the system will be freed.
O To establish communication pick up the monitor (telephone) handset. The communication will last for
one and a half minutes or until the handset is replaced. During the communication the door panel
display will show the message communication. Once the communication has finished the
system will be freed.
O To open the door, press the door release push button during call or communication progresses: with
one press, the door release operates during the programmed time. During the lock release
activation an acoustic tone will be heard on the door panel confirming the lock release is
activated, and the door panel display will show the message door opened.
O The monitor and telephone push buttons description is shown on pages 127 and 133 respectively.
Systems with general entrance door panel(s) and several internal buildings.
O To make a call from a general entrance door panel, the visitor should key-in the five digits code
corresponding to the apartment building he wishes to contact: the door panel display will show the
sequence keyed-in. Proceed as described on the previous paragraph to establish the call progress.
The corresponding internal door panel and the other general entrance door panels (if exist): if a
visitor tries to call an acoustic tone will be heard confirming the system is busy, and the door panel
display will show the message busy. The rest of door panels are free to establish communication.
O To make a call from an internal door panel proceed as described on the previous paragraph. The
rest of internal door panels are free to establish communication. A call from the general
entrance door panel can be made to any of the internal buildings, except to the one is in
communication.
Use of the repertory names.
O If the visitor don't know the code of the apartment he wishes to contact, he could find it on the
repertory name by searching through the arrow keys. Once the code has been found, the call can
be made by pressing the bell key. Refer to page 124 for details about fast repertory searching.
Lock release activation using the access control.
O To open the door using the access control facility, press KEY symbol and one of the valid access
codes. During the lock release activation an acoustic tone will be heard on the door panel
confirming the lock release is activated, and the door panel display will show the message
door opened. If an incorrect code has been keyed-in, press key and try again. The
introduction of three wrong consecutive codes freezes the access control during 60 seconds.
107
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar 5403 Stadio Plus - T3403ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar 5403 Stadio Plus - T3403ML in the language / languages: English as an attachment in your email.

The manual is 7,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Golmar 5403 Stadio Plus - T3403ML

Golmar 5403 Stadio Plus - T3403ML User Manual - English - 160 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - Dutch - 24 pages

Golmar 5403 Stadio Plus - T3403ML Installation Guide - Dutch - 52 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - French, Spanish - 160 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info