467816
144
Zoom out
Zoom in
Previous page
1/160
Next page
SEC
PRI
~~
+ +
--
142
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
-
JP
4321
CN1 CN2
D6L-Plus/2H
D6L-Plus/2H
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
1
4
7
2
5
8
3
6 0
9
C
FA-Plus/C or FA-Plus
Main
Master door panel
Place this power supply
as closest as possible
to the first distributor.
Take off JP1 jumper
of all the distributors
except in the last one.
JP1
A
A
D
D
CT +
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
JP1
A
A
D
D
CT +
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
Platea Uno Platea Uno
680W
OUTPUT
INPUT
OUTPUT
INPUT
*
Platea PlusPlatea Plus
143
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
-
JP
4321
CN1 CN2
1
4
7
2
5
8
3
6 0
9
C
INSTALLATION DIAGRAMS
Slave door panel
IMPORTANT: For this type of installation, the door panels must have plugged an EL560
module in each and the monitors must have an EL plugged in each.562
1,00mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5 CAT-5
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , M
in+,- out+,- p,d p,d
+, –, CV+, CV–
For longer distances than the specified contact with your distributor.
ideo installation without coaxial
cable.
v
The installation diagram shows the connection of a video system with one or several door
panels for the same building.
If the system has one door panel only, override the wiring to the second door panel.
If the system has more than one door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
Remember: if the installation has Uno telephones or monitors a resistor must be
installed between 'D' and '–' terminals of the door panel. In case of several
doorpanels place the resistor only on the one closest to the backbone. When
using a digital repeater RD-Plus/Uno, this operation is not necessary.
If the distance between the doorpanel and the last monitor or telephone exceeds 200
meters, or if the building has more than 200 monitors or telephones, a digital repeater RD-
Plus/Uno will be necessary.
A
in
A
out
D
+
-
CV
+
CV
-
SEC
PRI
~~
+ +
--
142
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
-
JP
4321
CN1 CN2
D6L-Plus/2H
D6L-Plus/2H
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
1
4
7
2
5
8
3
6 0
9
C
FA-Plus/C or FA-Plus
Main
Master door panel
Place this power supply
as closest as possible
to the first distributor.
Take off JP1 jumper
of all the distributors
except in the last one.
JP1
A
A
D
D
CT +
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
JP1
A
A
D
D
CT +
+
V
pi
V
d1
M
pi
M
d1
_
_
A
D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
V
p
M
p
A D
_
+
EL562
JP1
V
p
M
p
A D
_
+
EL562
JP1
Platea Uno Platea Uno
680W
OUTPUT
INPUT
OUTPUT
INPUT
*
Platea PlusPlatea Plus
143
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
-
JP
4321
CN1 CN2
1
4
7
2
5
8
3
6 0
9
C
INSTALLATION DIAGRAMS
Slave door panel
IMPORTANT: For this type of installation, the door panels must have plugged an EL560
module in each and the monitors must have an EL plugged in each.562
1,00mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5 CAT-5
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , M
in+,- out+,- p,d p,d
+, –, CV+, CV–
For longer distances than the specified contact with your distributor.
ideo installation without coaxial
cable.
v
The installation diagram shows the connection of a video system with one or several door
panels for the same building.
If the system has one door panel only, override the wiring to the second door panel.
If the system has more than one door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
Remember: if the installation has Uno telephones or monitors a resistor must be
installed between 'D' and '–' terminals of the door panel. In case of several
doorpanels place the resistor only on the one closest to the backbone. When
using a digital repeater RD-Plus/Uno, this operation is not necessary.
If the distance between the doorpanel and the last monitor or telephone exceeds 200
meters, or if the building has more than 200 monitors or telephones, a digital repeater RD-
Plus/Uno will be necessary.
A
in
A
out
D
+
-
CV
+
CV
-
680W
*
Main
FA-Plus/C
rev.938072
SEC
PRI
++
--
230 110 0
144


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Golmar 5403 Stadio Plus - T3403ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Golmar 5403 Stadio Plus - T3403ML in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 58,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Golmar 5403 Stadio Plus - T3403ML

Golmar 5403 Stadio Plus - T3403ML User Manual - English - 56 pages

Golmar 5403 Stadio Plus - T3403ML User Manual - Dutch - 24 pages

Golmar 5403 Stadio Plus - T3403ML Installation Guide - Dutch - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info