GM Electronics Ltd.
Golden Mask Deep Hunter pro2 – Instruction Manual
- "GROUND Man/AUTO" - potentiometer for setting the system to eliminate
the influence of ground.
In position "Man" System to eliminate the influence of ground is adjusted
manually.
In "AUTO" position detector uses a special automatic system to eliminate the
influence of ground.
- "RETUNE" - button for quick readjustment of the detector and remove the
interference in the searching process.
- "BOOST" - switch the additional amplification of the received signal:
- "OFF" - normal depth of detection;
- "ON" - about 20% extra depth of detection.
(After turning in the "ON" position must be made initial system setup to
eliminate the influence of ground in “manual mode”, or press and relies
"RETUNE" in “AUTO mode” );
- "SIGNAL" – analogue meter indicating the strength of the received signal
and level of charge the built-in battery; there are embedded 3 LEDs for
indicating the type of metal and the condition of the battery:
- "Fe", "n-Fe" - LED indication of the type of metal -
green for ferromagnetic metals and red for non-ferromagnetic metals;
- "Battery!" - LED for indicating less than 10% residual charge the built-
in battery, whereby it must be loaded (see item 8);
-"Battery Check" - button to check the level of battery charge. This button
can be used at any time. When the arrow is in the red sector, the battery should
be charged!