Slave Trigger Model
This model offers three choices which can be set by the optical control and
anti-preflash switch (5).
1. No optical control: the slave trigger indicator (10) is off, meaning that the
slavetrigger model is shut down.
2. One fire model: the slave trigger indicator (10) glows blue, meaning the flash
will fire synchronously on one external flash. This model can act as an auxiliary
lamp, varying the light effects.
3. Anti-preflash model: the slave trigger indicator (10) glows red, meaning the
flash will fire synchronously on the second flash. This model can act as an
auxiliary lamp, applicable to TTL system. And with anti-preflash function, it can
work for the cameras equipped with one fire anti-preflash system.
Modeling Lamp
Modeling lamp switch (6) decides whether the modeling lamp is on or off: modeling lamp
indicator (11) on, modeling lamp is turned on;
the indicator (11) off, modeling lamp is turned off.
The lamp can also turn off automatically for auto-self protection after lighting for 30 minutes.
Brightness of the lamp can be adjusted by Flash Output Controller (4).
Buzz Function
Buzz function can be set by the buzz button (7) and it is turned on when the
buzz indicator (12) is on; it is shut off when the buzz indicator (12) is off. A “BI”
sound will be heard whenit is fully charged and ready to fire.
Model
Flash Output
Guide Number (m ISO 100)
Color Temperature
Power Voltage
Flash Power Control
Modeling Lamp
Recharging Time
Flash Triggering Method
Flash Duration
Fuse
Dimension
Weight
120SDI 160SDI 250SDI 300SDI
120WS 160WS 250WS 300WS
38 43 48 58
5600±200K
220V/50Hz or 100V~120V/60Hz
8 steps
75W
0.5~2sec
Sync cord, Test button, Slave
1/2000-1/800s
5A
230*200*108MM
Approx.1.16KG
Shut down the device immediately when it works abnormally and find out the
reason.
Do not keep long time in using the modeling lamp. It's better to be
cooled down for one minute after five minutes continuous use.
Technical Data
Maintenance
07 08
Avoid sudden impacts and the lamp should be dedusted usually.
It's normal for lamp being warm when in use. Avoid continuous flashes when it
is not necessary.
Except that users can replace the plug-in tube and modeling lamp by themselves,
maintenance of all the flashes is up to our authorized maintenance department
which can provide original accessories.
One year warranty period will be canceled when any unauthorized maintenance is
found.
Disconnect the power when doing maintenance work or cleaning.
New changes made to the specification may not be updated in this manual.
If the product had failures or is wetted, it can be continuously used only after it
is repaired by professionals.
Tube Replacement
Turn down the power before replacing the flash tube and wear insulated gloves.
Then, loosen the iron wire on the tube, keep a balanced hold on the two feet of the
flash tube and pull out the old tube gently. Take down the feet casing to put it on
the new one. Hold two feet of the new tube, and target directly towards the two
copper outlets, then push them slightly in. Tighten the iron wire to fix the flash tube.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Godox Smart 120SDi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Godox Smart 120SDi in the language / languages: English as an attachment in your email.

The manual is 2,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info