6.1 Filling the device >>
Figures 14 - 15
/Remove the container cap and fill the device through the filling strainer. Close the
container with the container cap.
Note maximum fill level (see technical data), safety instructions and
permissible materials.
Check fill quantity.
Comply with the data of the spray product manufacturer!
6.2 Correctly fitting the shoulder strap / carrier system to the body >>
Figures 16 - 25
You can adjust your shoulder strap/carrier system (type-dependent) accurately to ensure
optimal load distribution and fatigue-free working. The device must be worn as close to the
body as possible and parallel to the spine.
Type Hobby 1200/1800: Padded shoulder strap
Fasten the shoulder straps as shown to the lower left and right outer strap buttons and
position the device on your back.
Tighten the carrying straps over the shoulders by pulling the lower strap ends.
The carrying straps can be lengthened or shortened by adjusting the strap buckles.
Type Hobby 1800: includes lap belt
Before the strap lengths are adjusted, it is first necessary to clip on and tighten the lap
belt of this device.
Then tighten the carrying straps of the shoulder straps.
Type Pro 1300/1800: Carrier system with chest strap (Pro 1800 includes a lap belt)
Place the device on your back.
Clip on the chest strap and adjust height and width as shown.
Tighten the shoulder straps by pulling the lower strap ends as shown.
Adjust the carrying straps of the shoulder straps by pulling the upper strap buckles as
shown until the device lies parallel on the back. Adjustment is only possible when the
device is off the shoulders.
Type Pro 1800: includes lap belt
The lap belt must be clipped in and tightened on this device before the lower straps
ends are pulled to tighten the straps.
Tighten the shoulder straps by pulling the lower strap ends as shown.
6.3 Spraying >>
Figures 26 - 32
You may be exposed to hazards that could injure you when handling the
device and the spraying pesticides. You must therefore always comply with the safety instruc-
tions/safety measures in this user manual, as well as the following instructions:
The device must only be operated when suspended in a vertical or steep upright position.
Move the pump lever from the top to the bottom. This will fill the air vessel and spray line
with spray.