Only use original GLORIA spare parts for repairs.
(see GLORIA spare parts shop https://shop.gloriagarten.de).
Repairs must only be carried out by a GLORIA service point.
It is forbidden to perform repair work on the container (such as welding and soldering).
Further accessories can be found at www.gloriagarten.de
7.3 Storage >>
Figures 45 - 46
You may be exposed to hazards that could injure you when handling the device
and the spraying pesticides. You must therefore store the device and the spraying agents out
of the reach of children.
Empty and clean the device as in Chapter 7.1.
/Loosen the container cap – Clip spraying lance onto the spraying lance holder –
Store the device without pressure and frost-free.
8 Problems with the device
8.1 Troubleshooting >>
9 Accessories/Spare parts
Flat spray nozzle: Art. No. 111.0000
Spray shield, type 260: Art. No. 260.0000
Spray shield, type 270: Art. No. 270.0000
Brass extension tube 0.5 m: Art. No. 124.0000
Brass extension tube 1.0 m: Art. No. 110.0000
Spraying device cleaner: Art. No. 1100.0000
Pump piston O-ring (Hobby 1200): Item no. 610544.0000
Pump piston O-ring
(Hobby 1800; Pro 1300; Pro 1800): Item no. 610421.0000
Silicone grease (tube) Item no. 728781.0000
Further accessories can be found at www.gloriagarten.de
NOTE!
Fault Cause Remedy
Device is leaking at the
screw connection Hose loose Tighten coupling nut and carry out
pressure test with water
Spray pattern of nozzle not
OK
Nozzle partially blocked
Filter in the quick closure
valve contaminated
Clean filter or nozzle
(see Fig. 36 - 37)
Pump lever stiff O-ring on the pump piston
degreased
Remove the piston from the pump
and regrease the O-ring (see Fig. 38 -
44)
Replace the O-ring in the case of
wear. Item no.: see accessories/spare
parts