l
The following is a basic guide for the upper
limits for more detailed testing of acid or al-
kaline agents:
- Nitric acid up to 7 %
- Acetic acid and propionic acid up to 10 %
- Citric acid und hydrochloric acid up to 3 %,
limited to brief use only
- Sulphuric acid up to 10 %
- Caustic soda up to 20 %
- Oils / oily media
Foreseeable misuse
l The device is
not
suitablefor:
- formic and hydrofluoric acid in any
concentration.
- Acids and alkalis in concentrations
greater than the amounts quoted or as
mixtures
- Fuels
- wetting agents (surfactants) that cause
or could promote the formation of cracks
in the plastics used.
- liquids at temperatures over + 30°C.
- inflammable liquids
- very tenacious or sticky liquids, or liquids
that leave residues, which cannot be
completely poured or flushed out of the
unit (oils and oil-bearing liquids).
l
The device is not suitable for storing any liq-
uids, in particular food (best-before date).
l
On request, the manufacturer of the unit
can make available a detailed list of the
materials used in the parts of the unit for
more detailed examination.
l
Unauthorised changes to the unit made by
the user or inappropriate use shall render
null and void the liability of the manufac-
turer for any damage caused as a result.
Getting Started
l
Unscrew the valve body (B) by rotating to
the left out of the container for filling.
l
Fill the tank, see ”Max. filling volume” in
the Technical data section and the tank
scale for details on the maximum amount
that can be put in.
WARNING
!
Health risk through leaking cleaning
fluid!!
A leaking device or leaking components may
result in draining or spouting of cleaning fluid.
For this reason, observe the following safety
instructions:
-
Check that the unit is in perfect condition
and properly sealed each time before use.
Pull up the safety / pressure relief valve (A)
by hand and check that it returns to the
starting position.
- Only operate or move device when standing
upright.
- Inspect all screw joints for tight fitting.