814087
6
Zoom out
Zoom in
Previous page
1/16
Next page
6.
Room temperature and humidity
These appliances are designed for use in rooms with a normal humidity and at
temperatures of approximately +5⁰ C to 30⁰C. The appliances are not suitable for use
in damp rooms or for frost protection.
Sounds
Depending on the model some stoves may produce sounds when in use. These
sounds are either from the ventilator, the engine or possible breakdown sounds.
Pellets may also be heard dropping into the fire grate.
Weather conditions
For safe use of the pellet stove it is important to ensure that the chimney can
produce the desired draught. This could be a problem in the transition period
(autumn and spring) or during bad weather conditions. (strong winds, mist etc.)
System requirements
Among other things, the correct settings of a pellet stove are strongly dependent on
the chimney and the flue pipe. Further on in this manual a few important
requirements are mentioned, though these may not be complete as the working of a
stove much depends on personal circumstances.
Good advice from a specialized company or a specialized engineer is always
important.
7.
Type of combustion
Pellets are a solid fuel. Lighting this kind of fuel takes more time than lighting
liquid fuel (for example oil fuel or gas). After starting up the stove the lighting
process takes up to 10 minutes until flames appear. After the warming up
process is completed the appliance adapts automatically to the required
settings. Switching off the stove also takes a few minutes before all the pellets
are burned and the flame is extinguished. The smoke extraction fan is
programmed to continue operating so that any smoke left is sucked out through
the chimney. At the same time the fire grate is cooled down ready to be lit
again.
Description of use
A Globe-Fire pellet stove is a special appliance which is only suitable for
domestic use and only suitable for burning wood pellets of the previously
mentioned standard. When in use the appliance produces warm air in the area
where it is standing. The appliance also radiates heat to the surfaces around it
and to the stove window. The wood pellets are transported automatically to the
fire grate and are burned by an electrical ignition.
Depending on the selected level the correct amount of pellets will be
transported to the fire grate. A regulated amount of air necessary for combustion
is sent to the fire grate. The fuel is burned in the fire grate and flue pipe,
supplying heat to the surroundings. The fumes that are released are drawn up
through the chimney to the outside with the support of the smoke extraction fan.
At certain recommended moments the ash and soot must be removed from the
fire grate. The stove window must also be cleaned. As mentioned before,
regular servicing is necessary.
A dirty stove window is not a defect and is not a reason for restitution.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Globe Fire Jacobus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Globe Fire Jacobus in the language / languages: English as an attachment in your email.

The manual is 1.8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Globe Fire Jacobus

Globe Fire Jacobus User Manual - German - 16 pages

Globe Fire Jacobus User Manual - Dutch - 16 pages

Globe Fire Jacobus User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info