814060
8
Zoom out
Zoom in
Previous page
1/8
Next page
.Efficiency
Tested stove Type 1: EN 13240: 2001+A2: 2007
Type
Heat output / Energy efficiency
.Nominal heat output
Fuel
Test-Nr.
.Minimal distance to
flammable materials:
Reading and follow up of given guidelines in the manuel
The connection of more stoves to one chimney is permitted
Approved German tests and CE mark EN 13240:2001 + A2:2007, according
DINplus and also according Art. 15A B-VG Ö-Norm Austria.
1. and 2. level 1. BimschV Germany and also Luftreinhalte-Verordnung
Switserland.
VKF Switserland
Globefire Ch.Leibfried GmbH, An der Bundesstraße 2,
D-49733 Haren / Ems, Germany
Declaration of performance Nr.
Test institute Number
.Heat output
.Room efficiency
Mechanic solidity
Surface temperature
Combustion products
.Flue gas temperature
Fire safety
.Fire behavior
Dust in Mg on 13% O2: 33 mg/Nm³
Values (converted): 21 mg/MJ
8 kW
RRF - 40071331
002-CPR-2013.06.10
6 - 12 kW
80,7 %
8 kW
Stove Comet ST 1017
25281
Side: 40 cm Rear: 20 cm Bottom: 0 cm
Front stove window: 80 cm
Wood and coal Time burning
- Globe fire -
15
Fulfilled
1625
Nox: 118mg/Nm³
CO: 875 mg/Nm³ OGC:53 mg/Nm³
74 mg/MJ 582 mg/MJ 34 mg/MJ
Fulfilled
Fulfilled
Fulfilled
CO-Emission: 875 mg/Nm³ - 582 mg/MJ
278 °C
A1
12.
Globe Fire recommendations
Lighting the fire:
Open the primary / secondary air vent.
Check to see if an eventual air vent or
pipe in your burner is open.
1. Open the fire / grid.
2. Place two large logs (10 cm thick) on the
fire grid completely covering the grid.
Use a round log or chopped wood.
3. Place a firelighter in the middle.
4. Light the firelighter.
5. When the firelighter starts to burn place two
large logs (10 cm) in the flames.
Close the door.
When the stove is hot (approx. 15 - 30 minutes)
close the grid.
Add further wood using 1, 2, or 3 logs. Make sure
the wood has a real glow of flames before doing
this. (to prevent smoke in the room)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Globe Fire Comet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Globe Fire Comet in the language / languages: English as an attachment in your email.

The manual is 2.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Globe Fire Comet

Globe Fire Comet User Manual - German - 8 pages

Globe Fire Comet User Manual - Dutch - 8 pages

Globe Fire Comet User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info