9. COOKING AND BAKING IN THE OVEN.
Preheat the oven well by keeping the oven control closed until the correct
temperature is reached.
The baking temperature is regulated by the oven control.
To ensure that food is baked evenly, turn baking tin occasionally.
The oven thermometer will give the exact temperature of the oven.
12. FIRE SAFETY DISTANCES.
Furniture and flammable wall.
The distance from the back of the stove is 20 cm.
From both sides 25 cm.
From the glass 80 - 100 cm.
Floor.
A flammable floor ( carpet, wood etc. ) must be protected by a fireproof plate that is 30 cm
wider on both sides and at least 50 cm in front.
Each type of stove may have different regulations so please consult the page on types of stoves
in your user’s manual to find the distances required.
13. PARTS.
It is only possible to replace parts with original parts belonging to the stove.
These parts can be ordered through your supplier.
The fireplace must under no circumstances be altered in any way.
11. ACTION TO BE TAKEN BY A CHIMNEY FIRE.
Using wet wood, burning at low temperatures or using the wrong sorts of fuel can
cause a depository of soot in the chimney.
This can result in a chimney fire.
In this case close all air vents and contact the fire brigade.
After the fire, get your chimney sweeper to check for any cracks that may have
occured and sweep the chimney.
14. CAPACITY.
This stove has been tested at 7,0 kW.
When adding fuel it is recommended not to use more than 3 blocks of wood.
When using brown coal use only 3 or 4 briquettes.
Do not open the stove door before the wood has burnt to a glow and
flames are no longer visible !!!
15. CAPACITY.
Capacity, depending on the building material used for your house and tested according
to European and German requirements:
Favourable conditions - To be calculated according to DIN 4701
Average conditions - 145
Unfavourable conditions - 98 m ³
10. FRESH AIR FLOW FOR MAXIMUM COMBUSTION.
As cookers are room air-dependent fireplaces that take their combustion air from
the surrounding space, the operator must ensure that there is sufficient combustion air.
With sealed windows and doors (e.g. in conjunction with energy-saving measures)
it is possible that the supply of fresh air is no longer guaranteed, which can impair
the draught behaviour of the cooker. This can affect your well-being andand possibly
your safety. It may be necessary to provide an additional supply of fresh air, e.g. by
installing an air flap near the cooker or byor laying a combustion air duct to the outside
or into a well-ventilated room.
Problems can also occur if an extractor hood with a high
extraction capacity is fitted in your kitchen and the house is well insulated.
Too much air will be taken out of the room causing smoke to be extracted
from the stove. This can be solved by placing an automatic switch in your extractor hood
which only works with a window open. These can be supplied by your electrician.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Globe Fire Alhena at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Globe Fire Alhena in the language / languages: English as an attachment in your email.

The manual is 1.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Globe Fire Alhena

Globe Fire Alhena User Manual - German - 8 pages

Globe Fire Alhena User Manual - Dutch - 8 pages

Globe Fire Alhena User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info