3. Installation
3.1 Control Device: on a commercially available concealed socket, Ø 55.
Caution! The device should always be installed with its retaining ring on top of the wallpaper.
a) Remove housing cover. Pull off setting knob. Loosen lid screw. Remove lid.
b) Electrical supply: in accordance with circuit diagram; solid conductor-section 1 to 2,5 mm². No
earth lead required. Earth lead terminals is only used for looping through.
When mounted properly, the requirements of protection class II are fulfilled.
c) Fit the thermostat on to the socket using a thread-moulding Flush mounted socket screw.
d) Put on housing lid. To do this, the lid must slot into the top left of the housing base.
e) Continue as under a) but in the opposite direction.
3.2 Sensor:
The sensor must fulfil the requirements of protection class II and absolutely must be laid in a protective
tube, together with sensor cable H03VV. In this way, the sensor is protected from damp and can easily
be replaced in the event of repair.
4. Instructions for the Fitter
The I-O switch on the control device is a single-pole switch disconnecting the device from the
mains and interrupting the electric circuit to the heating resistor in the floor.
For work on the load circuit, the power supply must at all times be disconnected. e.g. the fuse
removed.
The relay contact is closed when the sensor is disconnected, when the sensor is short-circuit, the
relay contact is open.
Caution!
In the event of a fault, electric potential may be present at the sensor.
5. Specifications
5.1 Control Device:
Order reference 0394 ..
Operating voltage AC 230 V 50 Hz
Permissible variation AC 195...253 V 50 Hz
Temperature range (number scale) , 2, 3, 4, 5 (= 10...50° C)
Switching current at AC 250 V 10 (4) A cos ϕ= 1
Breaking capacity 2,3 kW
Rated surge voltage 4,000 V
Switch Mains, "On/Off"
Red LED indicator Control device demands heat (heating operation)
Green LED indicator Temperature reduction "ON"
Contact (relay) 1 make contact (for heating) (not floating)
Temperature reduction (TA) approx. 5 K
Switching temperature difference approx. 1 K
Protective system conformity with EN 60529 housing in IP 20
Operating temperature T 40
Storage temperature -25 T 70
UP Underfloor Heating Thermostat 12/13 Page 2 of 5
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gira 0394 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gira 0394 in the language / languages: English as an attachment in your email.

The manual is 0,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gira 0394

Gira 0394 User Manual - German - 4 pages

Gira 0394 User Manual - Dutch - 4 pages

Gira 0394 User Manual - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info