2.2 Major Applications and Scope
The Fingertip Oximeter can detect SpO2 and pulse rate through patient’s nger,
and indicate the pulse intensity by the bar-display. This device is applicable
to home, hospital (including internal medicine, surgery, anesthesia, pediatrics,
emergency room etc.), oxygen bar, the community medical center, alpine area
and it also can be used before or after sports, and the like.
This device is not appropriate to be used for continuous monitoring.
2.3 Environment Requirements
Temperature:
Operating Temperature: 5°C ~40°C
Storage Temperature: -20°C~60°C
Humidity:
Operating Humidity: 30%~80%
Storage Humidity: 10%~100%
Atmospheric pressure:
Operating Pressure: 70kPa~106kPa
Storage Pressure: 50kPa~106kPa
2.4 Principle of Measurement
The measurement of pulse oximeter is that it uses a multi-functional oxyhe-
moglobinometer to transmit some narrow spectrum light bands through blood
samples and to measure attenuation of spectrum with different wavelengths
according wo the characteristic that RHb, O2Hb, Met Hb and COHb absorb the
light of different wavelength, thereby determining O2Hb saturation of different
fractions. O2Hb saturation is called “fractional” O2Hb saturation.
Fractional O2Hb saturation = [O2Hb / (RHb + O2Hb + Met Hb + COHb)] × 100
Oppositely, pulse oxygen oximeter measures functional O2Hb saturation:
Functional O2Hb saturation = [O2Hb / (RHb + O2Hb)] × 100
Present SpO2 oximeter transmits light of two wavelengths only, red light (wave-
length 660 nm) and infrared (wavelength 940 nm), to differentiate HbO2 from
HbR. One side of the sensor contains two LEDs, and the other side contains a
photoelectric detector.
SpO2 oximeter measures HbO2 saturation in the blood by the light plethysmo-
graph when the pulse beats. The result is quite precise when HbO2 saturation
is over 70% ~ 95%.
ENGLISH
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gima OXY 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gima OXY 5 in the language / languages: English as an attachment in your email.

The manual is 0.46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gima OXY 5

Gima OXY 5 User Manual - German - 17 pages

Gima OXY 5 User Manual - French - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info