Guidance and manufacturer’s declaration – electromagnetic immunity
The Non Contact Infrared Body Thermometer is intended for use in the electromagnetic
environment specied below. The customer or the user of Non Contact Infrared Body Ther-
mometer should assure that it is used in such an environment.
Immunity test IEC 60601 test
level Compliance
level Electromagnetic
environment - guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
±6 kV contact
±15 kV air ±6 kV contact
±15 kV air Floors should be wood, con-
crete or ceramic tile. If oor are
covered with synthetic material,
the relative humidity should be
at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for power
supply lines
±1 kV for input/
output lines
Not
applicable Mains power quality should be
that of a typical commercial or
hospital environment.
Surge
IEC 61000-4-5 ± 1 kV line(s)
to line(s)
± 2 kV line(s)
to earth
Not
applicable Mains power quality should be
that of a typical commercial or
hospital environment.
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
5% UT
(>95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
<5% UT
(>95% dip in UT)
for 5 sec
Not
applicable Mains power quality should
be that of a typical commer-
cial or hospital environment.
If the user of the Non Contact
Infrared Body Thermometer
requires continued operation
during power mains interrup-
tions, it is recommended that
the Non Contact Infrared Body
Thermometer be powered from
an uninterruptible power supply
or a battery.
Power frequency
(50Hz/60Hz)
magnetic eld
IEC 61000-4-8
30A/m 30A/m Power frequency magnetic
elds should be at levels char-
acteristic of a typical location in
a typical commercial or hospital
environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
ENGLISH
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gima HTD8816C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gima HTD8816C in the language / languages: English as an attachment in your email.

The manual is 0.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gima HTD8816C

Gima HTD8816C User Manual - French - 17 pages

Gima HTD8816C User Manual - Spanish - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info