Activating a fixed line network connection as a fallback send connection
You can activate the fixed line network connection on your phone as a fallback connection. If a
call attempt fails via VoIP (IP connection or Gigaset.net), an attempt is automatically made
(without prompting) to establish a connection via the fixed line network.
¤ . . . In Alternative Connection, activate the Automatic fallback to fixed line option
A fallback is used in the following situations:
The IP connections are busy (you can make calls on a maximum of two IP lines at the same
time)
The SIP server for the VoIP connection cannot be accessed
The VoIP connection has not yet been configured or has not been configured correctly
(e. g. incorrect password)
The phone does not have a connection to the Internet, e. g. because your router is
deactivated or not connected to the Internet.
SMS messages that are to be sent via a VoIP connection are not sen
t via the fallback connection.
Voice quality for VoIP connections
Functions to improve the voice quality on VoIP connections (IP or Gigaset.net) are available on
the web page:
¤ Settings Telephony Audio
The voice quality for VoIP connections is mainly determined by the voice codec used for
transferring the data and the available bandwidth of your DSL connection.
In the case of the voice codec, the voice data is d
igitised (coded/decoded) and compressed. A
"better" codec (better voice quality) means more data needs to be transferred, i. e. it requires a
D
SL connection with a larger bandwidth. You can change the voice quality by selecting (bearing
in mind the bandwidth of your DSL connection) the voice codecs your phone is to use, and
specifying the order in which the codecs are to be suggested when a VoIP connection is
established. Default settings for the codecs used are stored in your phone; one setting optimised
for low bandwidths and one for high bandwidths. The following voice codecs are supported:
G.722
Excellent voice quality. The broadband voice codec G.722 works at the same bit rate as G.711
(64 kbit/s per speech connection) but with a higher sampling rate. You can use this to play
back higher frequencies. The speech tone is therefore clearer and better than with the other
codecs (High Definition Sound Performance).
You can avoid having to assign connections to certain phone numbers by using a
dialling plan for these phone numbers.
Deactivate option if you are not connected to a fixed line network (default setting).
Otherwise, you will be switched automatically to the fixed line network if no IP
connection can be established temporarily, e. g. if the phone starts faster than the
router. The phone would therefore not be functional.
104


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gigaset S850 A GO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gigaset S850 A GO in the language / languages: English as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gigaset S850 A GO

Gigaset S850 A GO User Manual - German - 151 pages

Gigaset S850 A GO User Manual - Dutch - 141 pages

Gigaset S850 A GO User Manual - French - 145 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info