Base stations
63
Actions
Setting up the base station synchronisation
Select the cluster to which the base should be assigned to from the Cluster option menu.
Base stations only synchronise within the same cluster, meaning that a handover of a
handset from one cluster to a neighbouring cluster is not possible. The DECT multicell system
can manage up to nine clusters.
Select the synchronisation level for the base station from the DECT Level option menu.
DECT level 1 is the highest level and may appear only once in each cluster. A base station
always synchronises itself with a base station that has a better sync level. If it sees several
base stations with a better sync level, it synchronises itself with the base station that has the
strongest signal. If it does not see any base station with a higher sync level, it cannot synchro-
nise.
Mark the LAN Master check box, if the base station should act as LAN master.
If synchronisation via LAN is used, there must be one base station acting as LAN master.
Currently the LAN master can only be configured on DECT level 1.
This device should only be used as a base station. Devices on which the DECT Manager/Inte-
grator is active in addition to the base station are not suitable as LAN masters due to the
variety of tasks and traffic to be served.
From the Sync Slave option menu select whether the base station is to be synchronised via
DECT or via LAN. For the Sync master leave this column empty.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gigaset Pro N870E IP PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gigaset Pro N870E IP PRO in the language / languages: English as an attachment in your email.

The manual is 1.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gigaset Pro N870E IP PRO

Gigaset Pro N870E IP PRO User Manual - German - 151 pages

Gigaset Pro N870E IP PRO User Manual - Dutch - 150 pages

Gigaset Pro N870E IP PRO User Manual - French - 151 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info