Gigaset N870 IP PRO / Admin IE-UK-International en / A31008-XXXXX-XXXX-X-XX / settings_DM.fm / 8/10/21
Template Module, Version 2.1, 11.08.2020 / Template Basiseinstellungen: Version 3.1 - 07.07.2020
DECT manager configuration
43
Reference
Reference to the synchronizing external DECT system. In case of Best DECT base of DM and LAN
Master of DM the DECT manager identifier. In case of Ext RFPI xxx the RFPI or a part of an RFPI.
Actions
Adding a synchronization reference to the list
Click on Add . . . the DECT manager synchronization page is opened ( p. 38).
Deleting a synchronization reference from the list
Select the check box next to the sync reference you want to delete. Multiple choice is
possible. Click on Delete Confirm with Yes . . . all selected sync references are deleted.
Editing a synchronization reference
Click on next to the DECT manager synchronization you want to edit . . . the DECT
manager synchronization page is opened ( p. 38).
Adding/Editing a synchronization reference
This page allows you to define which DECT device is responsible to synchronize a cluster
managed by the DECT manager. You can edit an existing entry of the DECT manager synchroni-
zation table or add a new entry.
DM Name
For a new entry: Select a DECT manager from the option menu.
For an existing entry the identifier is shown.
Cluster
For a new entry: Select a cluster number of the selected DECT manager. Only one synchroni-
sation reference can be set for a cluster.
For an existing entry: The cluster number of the selected DECT manager is shown.
Cluster external sync
Select the cluster‘s synchronisation reference:
No external sync Level 1 base of the cluster will only synchronise internally.
Best DECT base of DM Level 1 base of the cluster will synchronise with the best accessible
base station of the DECT manager. The DECT manager must be
selected from the Reference option menu.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gigaset Pro N870E IP PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gigaset Pro N870E IP PRO in the language / languages: English as an attachment in your email.

The manual is 1.33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gigaset Pro N870E IP PRO

Gigaset Pro N870E IP PRO User Manual - German - 151 pages

Gigaset Pro N870E IP PRO User Manual - Dutch - 150 pages

Gigaset Pro N870E IP PRO User Manual - French - 151 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info