594668
26
Zoom out
Zoom in
Previous page
1/84
Next page
DATA MANAGER - GET DATA ACQUISITION SOFTWARE rev. 01
2013 - GET by Athena - All rights reserved
ENGLISH
26
Calibration Type: allows you to choose the type of calibration to use in the channel selected: A list of
types of calibration appears when you click on the button with the left button of the mouse button.
Make the choice based on the type of channel you are working on: e.g. for potentiometer sensors
choose Linear. Refer also to datalogger and/or sensor user manuals to find the proper channel
calibration
Fields X, Y: Allows the association of the values read by the sensors (in the fields marked with X) to
values set by the user (in the fields marked with Y). This combination of values defines that calibration
of the channel. By clicking on an X field and then clicking the Capture button on the top right corner of
the Calibration dialog box, the current value of the channel (Y field) is associated to the previously
selected X field.
WARNING: The direct acquisition procedure described above must be made with the GET data
acquisition connected to a PC.
If there is no data acquisition device connected to a computer you can enter the values in the X and Y
fields manually using the keyboard.
NOTE: consult the instruction booklet of the sensor being calibrated to know the XY values to
enter in the appropriate fields
The Show in volts option, if enabled, shows the voltage of the channel expressed in volts.
3.2.10.5 Applying an offset
You can use the offset the button to specify a value to be added or subtracted to the value read from the
selected channel. Use positive values to subtract the offset from the channel and negative values to add
offset, confirm the data entered with the OK button.
3.2.10.6 Mathematical channels
A mathematical channel is a channel which is obtained by applying the appropriate mathematical functions
to one or more of the previously acquired channels. It is possible, for example, to create the acceleration”
mathematical channel, using the speed derivative.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Get DATA MANAGER-SOFTWARE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Get DATA MANAGER-SOFTWARE in the language / languages: English as an attachment in your email.

The manual is 6,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info