620333
24
Zoom out
Zoom in
Previous page
1/28
Next page
20
GP VF 80 Set | HWW VF 100
ENGLISH
GB
Inspection and maintenance plan
Time interval Description Any other details
As needed Clean the check valve and the prelter. Check the check valve function.
Failures – causes - removal
Failures Causes Removal
Engine does not start No power supply.
Blocked pump wheel
Turn the engine shaft with screwdri-
verthrough the fan cover (to release
frictioncircles sealing that may be stuck
together).
Pump does not suck Missing, loose or blocked check valve
Check valve is not in water.
Pump without water
Too high suction head.
Air bubbles in the suction pipeline.
Connections not sealed, pump sucks air,
pump is not deaerated.
Prelter clogged
Fix or clean the check valve.
Immerse the check valve into water.
Fill the pump shell with water.
Check the suction head.
Check the tighten of suction pipeline.
Carefully repeat connection according to
thechapter „Connection“!
Clean the prelter.
10
Thermal detector swit-
ching the pump o
4
Pump is overheated and switched o by
thethermal overloading protection.
No electric power supply.
Impurity particles (e.g. pebbles) have
settleddown in the suction hole.
Let the device getting cool!
Check power supply.
Disassemble and clean the suction
hose,prevent from suction of foreign
substances.
Insucient amount of
water pumped
Too high suction head.
Strainer of the check valve dirty
Water level quickly drops down
Check the suction head.
Clean the strainer., Position the check valve
lower.
Clean the prelter 10
10
Clean the pump and replace worn parts.
(qualied workshop)
Reduced switching
intervals
Air pressure in the receiver too low Control air pressure.
11
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Germania HWW VF 100 - 05323 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Germania HWW VF 100 - 05323 in the language / languages: English, German as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info