803165
8
Zoom out
Zoom in
Previous page
1/12
Next page
en
20
300mbar to 1100mbar.
Press A to change the units of the barometric pressure value and hold it down
until the pressure unit (mbar or inHg) stops ashing to go from mbar to inHg
and vice versa. Press B to change between the barometric pressure values and
current values.
To convert pressure to inches of Mercury, use the following formula:
Pressure in inches of Mercury [inHg] = Pressure in millibars [mbar]/33.9
• View 2 : Temperature display.
In this view the watch displays sea level and local pressure values and
temperature. Change the units between (°C) and (°F) by holding down A.
WARNING: body temperature may inuence the value displayed. To get a
precise idea of the outside temperature, you need to take the watch off and
put it on an ambient temperature surface. Leave the watch to come to ambient
temperature (around 10 minutes) and the display will stabilise.
NB: The temperature varies in intervals of 0.1°C and the variations will be
recorded very precisely.
However, the accuracy of the absolute gure will be lower (1 to 2°C).
Comparing the display with another thermometer may lead to errors, as the
value depends on the calibration of the two devices.
• View 3 : Displaying local pressure.
The main display in this view shows the local pressure.
The watch measures altitude and atmospheric pressure using the same
sensor.
It cannot therefore determine whether the atmospheric pressure changes
because of a change in altitude or in climatic conditions.
You therefore need to calibrate the barometer to the altitude of the measurement
site.
Calibrating sea level atmospheric pressure.
• Calibration is only possible for views 1 to 3.
• Hold down D until the words SET CURRENT WEATHER scroll across the
screen. The weather symbol begins to ash.
• Press A(+) and B(-) p to increase or decrease the displayed value, depending
on the weather conditions observed at the time.
• Press C p the sea level pressure value ashes.
• Press A(+) and B(-) p to increase or decrease the displayed value, depending
on information from an ofcial meteorological bulletin, for example.
Press D to exit setting mode. After 2-3 minutes without calibration, the screen
stops ashing and goes back into barometer mode.
• View 4 : Differential barometer.
In view 4, it is possible to activate a differential mode. This allows you to
measure pressure changes from the moment it is activated, without having to
reset the barometer. This gives you a new benchmark for monitoring barometric
variations.
• Press D “START” is displayed.
• Hold down D until S.level and C.baro appear with ashing gures.
• Press A or B to reset the values to zero. You have just calibrated the benchmark
to launch the differential calculation.
• Press D to conrm the calculation.
• Hold down D until STOP stops ashing to interrupt the calculation.
A
B
A
B
A
B
Downloaded from www.Manualslib.com manuals search engine
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Geonaute MW600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Geonaute MW600 in the language / languages: English as an attachment in your email.

The manual is 0.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info