646566
19
Zoom out
Zoom in
Previous page
1/108
Next page
Installation Instructions
19
WARNING
USE ONLY METAL DUCT 4” DIAMETER (102 mm
FOR CANADA). DO NOT USE DUCT LONGER THAN
SPECIFIED IN THE EXHAUST LENGTH TABLE.
'U\HU([KDXVWLQJ,QIRUPDWLRQ³0HWDO'XFW2QO\
Ducting Materials: For best performance, this dryer
should be vented with 4” diameter all-rigid metal
exhaust duct.
Exhaust Length Calculation:
1. Determine the number of 90º turns needed for
your installation.
2. The maximum length of 4’ rigid (aluminum or
galvanized) duct which can be tolerated is shown
in the table.
A turn of 45º or less may be ignored. Two 45º
turns within the duct length should be treated
as a 90º elbow.
A turn over 45º should be treated as a 90º elbow.
CAUTION:
For personal safety, do not
terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic,
since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate
the exhaust into a common duct or plenum with a
kitchen exhaust, since the combination of lint and
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered
wall cap to prevent back drafts, bird nesting, etc.
The wall cap must also be located at least 12” above
the ground or any other obstruction with
the opening pointed down.
Other terminations, such as louvered wall boxes,
are acceptable provided they are equivalent to
a 4” opening dampered wall cap.
For more information on venting kits and
accessories, please call 1.800.GE.CARES.
Best Performance
Maximum Length
of a 4 Dia.
Rigid Metal Duct
Exhaust Hood Type
Number of A B
90º Turns 4 Opening 2-1/2 Opening
Front-Loading Dryers 0 90 ft. 60 ft.
1 60 ft. 45 ft.
2 45 ft. 35 ft.
3 35 ft. 25 ft.
4”
4”
2-1/2”
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for General Electric DCVH485EK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of General Electric DCVH485EK in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info