Wiring Diagrams
33722 D MMG130DI4/175DI4/205DI4 Operating Manual 51
DC WIRING
TO 3 POS LUG BLOCK T7
OR 31 POS DEUTSCH PIN 6 FOR PMG
SEE AC PRINT
TO
GND
BAR
BAR
GND
TO
TO
GND
BAR
TO
GND
BAR
BAR
GND
TO
TO
GND
BAR
TO
GND
BAR
TO
GND
BAR
BAR
GND
TO
BK
CLR
SHLD
TO
GND
BAR
TO
GND
BAR
FUEL
LEVEL
WT/VI
RD/VI
21
22
N
C
TO
GEN FIELD
LOW
COOLANT
GY/BK
BK/WT
BK
GEN
F-
RD
GEN
F+
6
3
2
20
8
13
31
30
15
14
19
11
12
21
22
1
5
18
4
23
7
10
28
29
24
25
26
27
9
16
17
31 PIN
OPTIONAL
HEATED
FUEL
FAN
OPTIONAL
CLUTCH
FILTER
GY/OR
BK/WT
LIGHT
INTERIOR
BK/WT
FUEL
OPTIONAL
XFER
PWR
GND
OPTIONAL
VI/YL
OPTIONAL
PMG
BK/WT
CONN 2
BN/WT
BN
BN
BN/WT
PUMP
RD/VI
E-STOP
SWITCH
GY/OR
BK/WT
RD/BK
BK/WT
BK/WT
BK/WT
RD/WT
RD/WT
CLR
FORCE REGEN
INHIBIT REGEN
LOW COOLANT
REMOTE START
FAN CLUTCH
LUG DOOR
FUEL XFER ENABLE
SHUNT TRIP
FUEL TRANSFER
ALARM
RED BEACON
OIL LEVEL
RECONNECT DOOR
LEAK DETECT
TO VOLTAGE REGULATOR SEE AC PRINT
FOR VREG CUTOUT
BK
RD
BL
BN/WT
OR/WT
YL/WT
GN/YL
WT
CT-1
CT-2
CT-3
WT
WT
BK/WT
RD/VI
RD/YL
WT/VI
BK/WT
OR
SWITCH
SERVICE
GY/OR
TB3
2
1
REMOTE
START
CONTACT
BK/WT
INHIBIT REGEN SWITCH
INHIBIT
MANUAL
AUTO
GND
BAR
BK/WT
TO
BK/WT
L3
L2
L1
SHUNT
MAIN
BREAKER
YL
YL
L0
WT WT
GN/YL
GN/YL
GN/YL
RD/BK
CONTROL
POWER
SWITCH
RD/BK
RD/WT
RD/BK
RD/BK
GY/YL
X
T
C
A
W
M
N
P
R
S
H
J
K
L
U
E
B
V
D
F
G
BK
RD
RD
21 PIN
CONN1
OR
CAN-LOW
CAN-HIGH
CAN-SHIELD
24 V
+
BATTERY
STARTERALT
RD
RD
30A
ENGINE
GND
BK
BK
CLR
SHLD
VI/YL
VI/YL
IGNITION
87
87A
86
30
85
RD/YL
RD
START
RD
RD
87
87A
86
30
85
FAN
CLUTCH
GY/YL
RD/VI
87
87A
86
30
85
RD/WT
FILTER
HEATED
RD/VI
BK
RD
VOLTAGE
TO
F-
F+
REGULATOR
RD/VI
TO EXPANSION MODULES
RD/VI
BK
AMB BEACON
OR/BK
OR/WT
OR/YL
TO VOLTAGE
REGULATOR
BK/WT
BATT
FUSED
FU&SW
20A
15A
20A
FUSE
BLOCK
RD/BK
POWER
TO DISPLAY
RD/BK
RD/WT
RD/WT
RD
RD
RD
RD
RD
RD
RD
OR
RD/VI
RD/VI
RD/WT
RD/WT
OR/BK
OR/WT
OR/YL
TO DISPLAY
RS485
RD/BK
BK/WT
SPARE
VI/YL
RD/VI
AB
A
BCDEFGHI J K
JIHGFE
GY/BL
GY/GN
WT
BN/WT
BN/WT
WT
BK
SEE AC PRINT
GY/BK
OR/WT
RD/BK
BK/WT
1
2
3
4
TB1
VI/YL
N.O.
4 POS
RD
RD/BK
PHASE
SWITCH
RD/BK
RD
TO VREG RELAY PIN 7
RECONNECT/LUG DOOR
RD/BK
LUG
DOOR
LEAK
DETECT
SWITCH
RECONNECT
DOOR
CT
SENSING
NEUTRAL
405 &
465
ALARM
RED
BEACON
AMBER
BEACON
OR/BK
OR/WT
OR/YL
BK/WT
LOAD SHED
BK/WT
GY
GY
BK/WT
GY/BK
SPARE
RD
BK/WT
WT/RD
WT/RD
BK/WT
OPTIONAL
OPTIONAL
OPTIONAL
OPTIONAL
SPARE
GY/OR
A
B
OPTIONAL
T8
OPTIONAL-DVR
FUEL
RD/VI
RD/VI
RD
RD/VI
RD/VI
WT/VI
WT/BL
BL
WT/BL
BL
BK/WT
YL
YL
WT/RD
BK/WT
GY
BK/WT
BK
CLR
SHLD
BK/WT
BK/WT
CNO
CNO
(HELD
CLOSED
NORMALLY)
(HELD
CLOSED
NORMALLY)
AC DWG
SEE
12V OR
BK
OR
MODULE 7740
CHRG ALT
MPU
FUEL LEVEL (FLEXIBLE)
BATTERY
+VE
-VE
OIL PRESSURE
11 INPUTS
FUEL
CRANK
COMMON GROUND
WATER TEMP
CLOSE
GEN
D
OUTPUT
AUX FUEL TANK SENDER
C
OUTPUT
FLEXIBLE IF
J1939 IS USED
SCR
46454443 4241 3924 2322
676665646362616019181716 15 65431
2
GEN VOLTS
WVU N
SCR
B
A
RS232
L3L2L1
RS485
V1
+VE
6 FET OUTPUTS
GOVERNOR AVR
O/P O/P
LHSCR
ENGINE ECU
MSC
SCR H LB A SCR
5640 302928 57 50494847
6968 71110983837363534 27 2625
323133
BA AB
12 13
BUS VOLTS
N
STR
PORT
PROGRAMMING
USB
L2 L3L1
70
USB HOSTRJ45
ETHERNET
S2
S1
L1 LOAD
CURRENT
8660 ONLY
V2
90438_H_11.02.15
1. TO ADD OPTIONAL REMOTE ANNUNCIATOR (COMMUNICATIONS)
FOR ATT GENERAC USE ANALOG EXPANSION MODULE.
2. TO ADD OPTIONAL ANALOG GAUGES USE ANALOG EXPANSION MODULE.
NOTES:
COMCT4
L3S1L2S1
GEN CURRENT
L1S1
CT1
CT2 CT3
NS1
5455535251
57


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Generac MMG205DI4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Generac MMG205DI4 in the language / languages: English as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info