33722 D MMG130DI4/175DI4/205DI4 Operating Manual 29
Figure 3-7. Voltage Selector Switch
VOLTAGES AT RECEPTACLES
277/480V 3-PHASE
Switch styles vary by model.
L1-L2 = 480V L1-N = 277V N =
L2-L3 = 480V L2-N = 277V
L3-L1 = 480V L3-N = 277V
277/
480V
120/
208V
RECEPTACLE L-L L-N
GFCI - 139V
GFCI w/Buck - 120V
Twist-locks 240V 139V
00083
= Not recommended for normal use
L1-L2 = 208V L1-N = 120V N =
L2-L3 = 208V L2-N = 120V
L3-L1 = 208V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/208V 3-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 208V 120V
277/
480V
120/
208V
120/
240V
00085
L1-L2 = 240V L1-N = 120V N =
L2-L3 = 240V L2-N = 208V
L3-L1 = 240V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/240V 3-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 120V 0/120V
120/
240V 3PH
277/
480V
120/
208V
120/
240V
1PH
4 Position Voltage Selector Switch Option
00086
= Not recommended for normal use
L1-L2 = - L1-N = 120V N =
L2-L3 = - L2-N = -
L3-L1 = 240V L3-N = 120V
VOLTAGES AT RECEPTACLES
120/240V 1-PHASE
Switch styles vary by model.
RECEPTACLE L-L L-N
GFCI - 120V
GFCI w/Buck - 120V
Twist-locks 240V 120V
120/
208V
120/
240V
00087
= Not recommended for normal use.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Generac MMG205DI4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Generac MMG205DI4 in the language / languages: English as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info