685346
39
Zoom out
Zoom in
Previous page
1/68
Next page
Operation
33722 D MMG130DI4/175DI4/205DI4 Operating Manual 33
AUTO EXERCISE TIMER
The Power Zone™ controller is capable of starting and stopping the unit automatically, based on a programmable
schedule.
Units installed in a standby application should be exercised regularly to maintain operating condition and to ensure
responsiveness in an emergency situation. Use the following procedures to operate the unit in Auto mode:
Accessing the Configuration Menu
1. With the unit stopped, press , , , or to navigate to the maintenance screens from any of the operator
screens.
2. While on any maintenance screen, press and O simultaneously. The controller will display the Configura-
tion menu.
3. To save any changes and exit the Configuration menu, press and hold for five seconds. To cancel any
changes and return to the maintenance screen, press and hold O for five seconds.
Set the Controller Clock
The schedule runs based off the time set in the controller clock. Use the following procedure to set the controller
clock BEFORE setting the schedule:
1. Navigate to the Maintenance group and press to access it.
2. Press to select the Time section.
3. Set the time and date to the correct local time.
Set the Schedule
1. Access the Scheduler group by pressing the button.
Note: The Scheduler group is made up of the Scheduler Options and Scheduler Setup sections. Each section can
be accessed and exited using the and buttons.
2. Access the Scheduler Options section. Within this section, the scheduler can be enabled, run mode
selected, and load mode selected.
3. Access the Scheduler Setup section. Within this section, each schedule entry can be modified by pressing
the button to select the item and the and buttons to define them.
Item Values
Enable Yes/No
Run Mode Monthly/Weekly
Load Idle, In Island, On Load, Off Load
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Generac MMG175DI4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Generac MMG175DI4 in the language / languages: English as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info